Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FMD77 differential pressure transmitter

FMD77 differential pressure transmitter
Deltabar S FMD77
Differential pressure transmitter with single flange diaphragm seal, used for liquid level measurement.
Compare

Continuous / Liquids

Measuring Principle Differential pressure
Characteristic / Application Digital transmitter with metallic measuring diaphragms one side with diaphragm seal
Modular transmitter
Long term stability
Enhanced safety via self diagnostic functions
Secondary process barrier
Supply / Communication 4...20 mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC
Accuracy 0,075% + influence of diaphragm seal
Long term stability 0,05% of URL/year
Ambient temperature -50°C...85°C
(-58°F...185°F)
Process temperature -40°C...400°C
(-40°F...752°F)
Process pressure / max. overpressure limit 160bar (2400 psi)
Pressure measuring range 100mbar...16bar
(1.5psi...230 psi)
Main wetted parts Alloy C276
316L
Monel
Tantalum
Process connection Low pressure side:
1/4-18NPT
RC1/4"
High pressure side:
Flanges (DIN, ASME, JIS)
Max. measurement distance 160m (525ft) H2O
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC
Safety approvals SIL
Design approvals EN10204-3.1
NACE MR0175, MR0103
Options HistoROM/M-Dat
4-line digital display
SS- or Aluminiumhousing
Separate housing
Successor PMD78B
Application limits Measuring cell:
Metal welded

Pressure

Measuring Principle Differential pressure
Characteristic Digital transmitter with metallic measuring diaphragms, one side with diaphragm seal
Modular transmitter
Long-term stability
Secondary process barrier
enhanced saftey via self diagnostic functions
Supply voltage 4...20mA HART
10,5...45V DC (Non Ex):
Ex ia: 10,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)
Reference Accuracy 0,075% + influence of diaphragm seal
Long term stability 0.08 % of URL/ year
0.14 % of URL/ 5 years
0.27 % of URL/ 10 years
Process temperature -40°C...400°C
(-40°F...752°F)
Ambient temperature -50°C...85°C
(-58°F...185°F)
Measuring cell 100 mbar...16 bar
(40 inH20...240 psi)
Smallest calibratable span 5 mbar (0.075 psi)
Vacuum resistance 50 mbar (0.73 psi)
Max. Turn down 100:1
Max. overpressure limit 160 bar
(2400 psi)
Process connection Low pressure side:
1/4-18NPT
RC1/4"
High pressure side:
Flanges (DIN, ASME, JIS)
Material process membrane 316L, AlloyC,
Tantal,
Gold-Rhodium,
PTFE
Material gasket None, diaphragm seal welded
Fill fluid Silicone oil,
Inert oil,
Vegetable oil
Low- temperature oil
High- temperature oil
Material housing 316L, Die-cast aluminum
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC, UK Ex
Safety approvals SIL
Design approvals NACE MR0175
EN10204-3.1
Specialities Diagnostic functions
Successor PMD78B

The Deltabar FMD77 differential pressure transmitter uses a metal sensor with a single-flange diaphragm seal or double-flange seal, with a capillary on the low-pressure side. It is mainly used for the continuous level measurement in the process industry. The built-in HistoROM data module facilitates process and device parameter management. It complies with IEC 61508 and meets SIL3 functional safety requirements.

 

Advantages

Excellent repeatability and long-term stability

High reference accuracy: up to ±0.075%, platinum version: ±0.05%

The new TempC diaphragm minimizes the influence of ambient and process temperature changes

For flow and differential pressure monitoring to SIL3 requirements, compliant with IEC 61508, certified by TÜV SÜD

HistoROM®/M-DAT memory module

Function monitoring of measuring cell and circuitry

Modular continuous measurement of differential pressure, static pressure and pressure (Deltabar S - Deltapilot S, Cerabar S), e.g. replaceable display, universal electronics for pressure and differential pressure measurement

 

Areas of application

For liquid level, volume or mass measurement

 

Process connections: thread and flange

Temperature: -70 ... +400°C (-94 ... +752°F)

Measuring range: +100mbar ... +16bar (+1.5 ... +240psi)

Accuracy: ±0.075%

International explosion protection approval, WHG overflow protection, hygienic approval, marine approval, SIL

Spare Parts & Accessories 76

76 spare parts · click to collapse
Order codeDescription
52020440mounting kitconsists of: 2x O-ring 45.69x2.62 EPDM retaining ring, plastics Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
71020596mounting kitconsists of: 2x O-ring 45.62x69x2.62 EPDM 1x profile gasket 51.4x57.2x1.6 VMQ retaining ring, plastics Cerabar S PMC71/PMP71/PMP75 Deltabar S PMD70/PMD75/FMD76/FMD77/FMD78 Deltapilot S FMB70Details
52022418key housingfor external operation consists of: push buttons, cover + screwsDetails
52022419key housingfor external operation consists of: push buttons, cover + screws colour: light greyDetails
52024110key housingfor external operation consists of: push button, cover + screws colour: dark greyDetails
52020760cable glandconsists of: cable gland M20 O-ring 18.72x2.62 VMQ Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
52020761cable entryconsists of: gasket 18.72x2.51 NBR adapter M20 > G1/2 O-ring 18.77x1.78 NBR Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
52020762plug connectorHarting plug set Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
52020763plug connectorCerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
71111056Atmospheric compensation filter portConsists of: Vent screw 304. Pressure compensation filter. O-ring EPDM, protection lid. Usage: FMB50, FMB51, FMB52, FMB53, FMD71, FMD72, FMD76, FMD77, FMD78, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, PMC51, PMC71, PMD70, PMD75, PMP71, PMP75, PMP51, PMP55.Details
71219639Atmospheric compensation filter portConsists of: vent screw 304. Pressure compensation filter. O-ring VMQ, protection lid. Usage: housing T17, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/ PMP75. Housing F15 at B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.Details
71206971Seal ring assemblyConsists of: 5x O-ring 75.87x2.62 FVMQ. Usage: housing T14, FMD77/FMD78, PMD70/PMD75, PMP71/PMP75.Details
52020432Aluminum cover with gasketMaterial: Aluminium, coated O-ring EPDM, FDA not for EEx d/XP Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
52020433Aluminum cover with gasketMaterial: Aluminium, coated O-ring EPDM, FDA for EEx d/XP Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78Details
52028309***Cover T14 316L, Ex d, sight glass, EPDMMaterial: 316L Sight glass: mineral glass O-ring EPDM, FDA individual tested, EEx d/XP Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78Details
52028310Stainless Steel CoverMaterial: 316L O-ring EPDM, FDA individual tested, EEx d/XP Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78Details
71002774Stainless Steel CoverMaterial: 316L flat gasket VMQ, centering ring, screw not for EEx d/XP Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
71002810cover with viewing windowMaterial: 316L Sight glass: mineral glass flat gasket VMQ, centering ring, screw approval 2,3,4,8,Q,W,7,8 Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
71002811cover with viewing windowMaterial: 316L Sight glass: Polycarbonat PC flat gasket VMQ, centering ring, screw approval A,F,R,S,U,1,6 Cerabar S PMC71, PMP71/PMP75 Deltabar S PMD70/PMD75,FMD76/FMD77/FMD78 Deltapilot S FMB70Details
71206965Stainless Steel CoverMaterial: 316L. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
All documents for this model
12 documents · click to expand
BA

Deltabar S FMD77, FMD78, PMD75 HART V02.30.zz Operating Instructions Chinese

HART Rev. 2122 80 pages
Preview
BA

Deltabar S FMD77/78; PMD75 FOUNDATION Fieldbus (V 04.00.zz) Operating Instructions Chinese

FOUNDATION-Fieldbus Rev. 2022 112 pages
Preview
BA

Deltabar S FMD77/78; PMD75 PROFIBUS PA (V 04.01.zz) Operating Instructions Chinese

PROFIBUS-PA Rev. 2022 96 pages
Preview
BA

仪表功能描述 Cerabar S PMC71, PMP71/75 Deltabar S FMD76/77/78, PMD70/75 Deltapilot S FMB70 Chinese

Rev. 1413 168 pages
Preview
BA

Deltabar S FMD77, FMD78, PMD75 HART V02.30.zz Operating Instructions English

HART Rev. 2122 80 pages
Preview
BA

Deltabar S FMD77/78; PMD75 FOUNDATION Fieldbus (V 04.00.zz) Operating Instructions English

FOUNDATION-Fieldbus Rev. 2022 112 pages
Preview
BA

Deltabar S FMD77/78; PMD75 PROFIBUS PA (V 04.01.zz) Operating Instructions English

PROFIBUS-PA Rev. 2022 96 pages
Preview
BA

Cerabar S / Deltabar S / Deltapilot S HART V02.30.zz Description of Instrument Functions English

HART Rev. 1816 148 pages
Preview
BA

Cerabar S / Deltabar S / Deltapilot S, Description of device functions FOUNDATION Fieldbus V 04.00.zz English

FOUNDATION-Fieldbus Rev. 1716 258 pages
Preview
BA

Cerabar S /Deltabar S /Deltapilot S Description of device functions PROFIBUS PA V04.01.zz English

PROFIBUS-PA Rev. 1616 170 pages
Preview
BA

Cerabar S /Deltabar S /Deltapilot S Description of device functions PROFIBUS PA English

PROFIBUS-PA Rev. 0510 174 pages
Preview
TI

TI Deltabar S PMD75, FMD77, FMD78 Chinese

Rev. 3524 114 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Differential Pressure Measurement — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Differential Pressure Measurement properly configured on the existing plant, with the aim of differential pressure for flow and filter monitoring.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Differential Pressure Measurement configuration has to involve checking static pressure limit, overload margin and impulse lines.

Configuration

Supply and installation were organised through the pressure range: pressure solution matched to process pressure and temperature. On site this meant checking static pressure limit, overload margin and impulse lines, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is filters changed on pressure drop, using cartridges to their full life, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Differential Pressure Measurement — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was differential pressure for flow and filter monitoring.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means checking static pressure limit, overload margin and impulse lines.

What We Did

We took a pressure range approach — pressure solution matched to process pressure and temperature. Delivery was built around checking static pressure limit, overload margin and impulse lines, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — filters changed on pressure drop, using cartridges to their full life, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Differential Pressure Measurement — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Differential Pressure Measurement, focusing on differential pressure for flow and filter monitoring.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Differential Pressure Measurement specification must therefore cover checking static pressure limit, overload margin and impulse lines.

Delivery Approach

Delivery was handled as the pressure range — pressure solution matched to process pressure and temperature. Execution centred on checking static pressure limit, overload margin and impulse lines, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — filters changed on pressure drop, using cartridges to their full life, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Differential Pressure Measurement — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Differential Pressure Measurement; the focus is differential pressure for flow and filter monitoring.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with checking static pressure limit, overload margin and impulse lines.

Implementation

The scope ran through the pressure range: pressure solution matched to process pressure and temperature. Technically it hinges on checking static pressure limit, overload margin and impulse lines, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means filters changed on pressure drop, using cartridges to their full life, which cut the workload on the site maintenance team.