Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

PMD78B E+H differential pressure transmitter

PMD78B E+H differential pressure transmitter
Deltabar PMD78B
TempC membrane helps minimize the impact of environmental and process temperature on measurement
Compare

Continuous / Liquids

Measuring Principle Differential pressure
Characteristic / Application Smart differential pressure transmitter with one or two capillaries, full range of certifications and Heartbeat Technology.
Intuitive and clear wizards for commissioning, proof tests and verification.
Specialities Heartbeat Technology,
Bluetooth® Operation and maintenance SmartBlue App,
LED Module,
RFID TAG for easy identification,
Plug and play functionalities
HistoROM
Supply / Communication Ex d, Ex e, non-Ex::
10.5...35V DC
Ex i: 10.5...30V DC
Accuracy Standard:
up to 0.1 %
Long term stability 0.025 % of URL/ year
0.05 % of URL/ 5 years
0.10 % of URL/ 10 years
Ambient temperature -54°C...+85°C
(-65°F...+185°F)
Process temperature -40°C...+400°C
(-40°F...+752°F)
Process pressure / max. overpressure limit 160 bar (2.400 psi)
Pressure measuring range 100 mbar...40 bar
(1.5psi...600 psi)
Main wetted parts 316L, AlloyC,
Tantal, Monel
PTFE, Gold
Process connection Thread:
MNPT1/2, G1/2
Flange:
NPS 2"...4", DN50...100
Max. measurement distance 160 m (525 ft) H2O
Communication 4...20 mA HART
PROFIBUS PA
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional)
Certificates / Approvals ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex
Safety approvals SIL
Design approvals EN 10204-3.1,
NACE MR0175,
NACE MR0103
Options Touch control display
Application limits Keine

Pressure

Measuring Principle Differential pressure
Characteristic Specialist with one or two capillaries for accurate differential pressure measurement.
Intuitive and clear wizards for commissioning, proof tests and verification.
Supply voltage Ex d, Ex e, non-Ex:
10.5...35V DC
Ex i: 10.5...30V DC
Reference Accuracy Standard:
up to 0.1 %
Long term stability 0.025 % of URL/ year
0.05 % of URL/ 5 years
0.10 % of URL/ 10 years
Process temperature -70°C...+400°C
(-94°F...+752°F)
Ambient temperature -40°C...+85°C
(-40°F...+185°F)
Measuring cell 100 mbar...40 bar
(1.5 psi...600 psi)
Smallest calibratable span 5 mbar (0.075 psi)
Vacuum resistance 50 mbar (0.73 psi)
Max. Turn down 100:1
Max. overpressure limit 240 bar
(3600 psi)
Process connection Thread: MNPT1/2, G1/2
Flange: NPS 2"...4", DN50...100
Material process membrane 316L, AlloyC,
Tantal,
Monel
PTFE
Gold
Material gasket PTFE, FKM,
EPDM, FFKM
Fill fluid Silicone oil,
inert oil,
vegetable oil,
low- / high temperature oil
Material housing Aluminium, 316L
Communication 4...20 mA HART
PROFIBUS PA
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional)
Certificates / Approvals ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex
Safety approvals SIL
Design approvals EN10204-3.1,
NACE MR0175,
NACE MR0103
Specialities Heartbeat Technology,
Bluetooth® Operation and maintenance SmartBlue App,
LED Module,
RFID TAG for easy identification,
Plug and play functionalities,
HistoROM

PMD78B is a member of the new generation of Deltabar transmitters. The transmitter is robust and features a secure Bluetooth connection, allowing remote operation of the instrument via a mobile device with the app installed. It supports on-demand maintenance and increases plant availability.
The software is equally easy to use. The intuitive operating wizard guides the user step by step through instrument setup, functional safety tests and verification tests.
Heartbeat Technology provides self-verification and self-monitoring functions that can detect process anomalies, such as blocked impulse lines.

Benefits
Wireless remote control of devices in hard-to-reach areas using the SmartBlue App

  • Reduced risk of system failure, error-free SIL commissioning and guided functional safety testing of the instrument

  • Heartbeat Technology verifies instrument health without interrupting the process. Increases plant availability.

  • Clear instrument status indication: the instrument immediately switches from green to red display as soon as a diagnostic message occurs

Applications
Maximum working pressure 40 bar (600 psi)

  • Maximum temperature of 400°C (752 °F) for instruments with diaphragm seal systems

  • Maximum working static pressure 160 bar (2400 psi)

  • Highest measurement accuracy of +/- 0.075%

 

Spare Parts & Accessories 70

70 spare parts · click to collapse
Order codeDescription
71487198Blind plug, M20, 316L, O-ring EPDMConsists of: blind plug, O-ring PTFE coated 17.0x2.0. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71487199Plug: M20, aluminum, EPDM sealing ringConsists of: blind plug, O-ring PTFE coated 17.0x2.0. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71679712Blind plug M20, 316L, Ex dConsists of: Plug IEC/ATEX Ex d marking o-ring PTFE coated 17,0x2,0. Usage: FMG50, FMP51, FMP52, FMP54, FMP55, FMP56, FMP57, FMR51, FMR52, FMR53, FMR54, FMR57, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL62, FTL64, OFMP51, OFMP57, OFMR51,OFMR54, OFTL51B, PMC71B, PMD50, PMD75B, PMD78B, PMP50, PMP71B.Details
71679714Blind plug M20, Alu, Ex dConsists of: Plug IEC/ATEX Ex d marking, o-ring PTFE coated 17,0x2,0. Usage: FMG50, FMP51, FMP52, FMP54, FMP55, FMP56, FMP57, FMR51, FMR52, FMR53, FMR54, FMR57, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, OFMP50, OFMP51, OFMP57, OFMR51, OFMR54, OFTL41, OFTL51B, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71679718Blind plug NPT1/2, Alu, Ex dConsists of: Plug IEC/ATEX Ex d marking, PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71487201Blind plug, NPT1/2, aluminumConsists of: blind plug, PTFE coated. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71487203Blind plug, NPT1/2, 316LConsists of: blind plug, PTFE coated. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71679715Blind plug NPT1/2, 316L, Ex dConsists of: Plug IEC/ATEX Ex d marking, PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, PMC71B, PMD50, PMD75B, PMD78B, PMP71B, PMP50.Details
71435135Cable gland M20, plastic, suitable for models: FTL41, FTL51B, PMC51B, PConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMB70, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD63B, PMD75B, PMD78B, PMP50, PMP51B, PMP63B, PMP71B.Details
71701449Cable gland, blue, M20, plasticConsists of: Cable gland blue M20x1.5, PA, O-ring 17.0 x 2.0 PTFE coated. Usage: FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71435136Cable gland M20, nickel-plated brass, suitable for: FMG50, FTL41, FTL51B, PConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71435137Cable gland M20, 316L, suitable for models: FMG50, FTL51B, PMC51BConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71440660M20x1.5-G1/2 adapter, aluminumConsists of: Adapter set, O-ring, 17.0 x 2.0 PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71440667M20x1.5-G1/2 adapter, 316LConsists of: Adapter, O-Ring 17.0 x 2.0 PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71435138Plug connector M20, nickel-plated brass, suitable for: screw-in thread, FMG50Usage: M12 screw-in thread, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71435139M12 plug, 316L, APL, housing sideUsage: M12 screw-in thread. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64, FTM50, FTM51, FTM52, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
52006263Process connection | Socket for plug 4p-125V, 4A-M12M12 插头 自连接 M12转成格兰Details
71439098Connector HAN7D, 90°, IP65, suitable for: FMG50, PMC51BUsage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71474251Enclosure grounding terminal L+PConsists of: spring washer, screw, earth handle, clamp. Usage Liquiphant: Only for digital communication. Usage: FHX50B, FMG50, PMD50, PMD55B, PMD63B, PMD75B, PMD78B, PMC51B, PMC71B, PMP50, PMP51B, PMP63B, PMP71B, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64.Details
71435116Housing cover, aluminum, sealed cover, O-ring, HNBR. Suitable for models: FMG50, FTL41, FTLSealing ring, HNBR. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source: Endress+Hauserpublic information from the website

All documents for this model
8 documents · click to expand
BA

BA Deltabar PMD78B Chinese

Rev. 0925 100 pages
Preview
BA

BA Deltabar PMD78B Chinese

Rev. 0525 106 pages
Preview
BA

BA Deltabar PMD78B Chinese

Rev. 0125 96 pages
Preview
BA

BA Deltabar PMD78B English

Rev. 0925 110 pages
Preview
BA

BA Deltabar PMD78B English

Rev. 0525 114 pages
Preview
BA

BA Deltabar PMD78B English

Rev. 0125 102 pages
Preview
TI

TI Deltabar PMD78B Chinese

Rev. 1025 96 pages
Preview
TI

TI Deltabar PMD78B English

Rev. 1025 96 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Differential Pressure Measurement — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Differential Pressure Measurement properly configured on the existing plant, with the aim of differential pressure for flow and filter monitoring.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Differential Pressure Measurement configuration has to involve checking static pressure limit, overload margin and impulse lines.

Configuration

Supply and installation were organised through the pressure range: pressure solution matched to process pressure and temperature. On site this meant checking static pressure limit, overload margin and impulse lines, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is filters changed on pressure drop, using cartridges to their full life, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Differential Pressure Measurement — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was differential pressure for flow and filter monitoring.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means checking static pressure limit, overload margin and impulse lines.

What We Did

We took a pressure range approach — pressure solution matched to process pressure and temperature. Delivery was built around checking static pressure limit, overload margin and impulse lines, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — filters changed on pressure drop, using cartridges to their full life, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Differential Pressure Measurement — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Differential Pressure Measurement, focusing on differential pressure for flow and filter monitoring.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Differential Pressure Measurement specification must therefore cover checking static pressure limit, overload margin and impulse lines.

Delivery Approach

Delivery was handled as the pressure range — pressure solution matched to process pressure and temperature. Execution centred on checking static pressure limit, overload margin and impulse lines, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — filters changed on pressure drop, using cartridges to their full life, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Differential Pressure Measurement — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Differential Pressure Measurement; the focus is differential pressure for flow and filter monitoring.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with checking static pressure limit, overload margin and impulse lines.

Implementation

The scope ran through the pressure range: pressure solution matched to process pressure and temperature. Technically it hinges on checking static pressure limit, overload margin and impulse lines, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means filters changed on pressure drop, using cartridges to their full life, which cut the workload on the site maintenance team.