FMR533 Micropilot SDiscontinued

FMR533 Micropilot S
Micropilot S FMR533Discontinued
Micropilot FMR533 is used for custody transfer and inventory control applications with NMi- and PTB-approvals. It meets the relevant requirements according to OIML R85 and API 3.1B. The FMR533 radar with parabolic antenna is excellently suited for free space applications up to 40m (131ft). Micropilot FMR533 offers cost-effective and simple installation via 4-wire cable with HART and 24 V DC intrinsically safe power supply.
Compare

Continuous / Liquids

Measuring Principle
Supply / Communication 4-wire (HART)
Frequency C-band (~6 GHz)
Accuracy +/- 1 mm, custody transfer
Ambient temperature Standard:
-40 °C ... 80 °C
(-40 °F ... 176 °F)
For calibration to regulatory standards:
-25 °C ... 60 °C
(-13 °F ... 131 °F)
Process temperature -40 °C ... 200 °C
(-40 °F ... 392 °F)
Process pressure / max. overpressure limit Vacuum ... 16 bar
(Vacuum ... 232 psi)
Main wetted parts 316L + PTFE
Process connection DN150 ... DN250 / 6" ... 10"
Communication 4 ... 20 mA HART
Certificates / Approvals ATEX, FM, CSA, IEC Ex, NEPSI
Safety approvals Overfill prevention WHG

The Micropilot FMR533 is approved by NMi and PTB, can be used for custody transfer and inventory control, and complies with the relevant requirements of OIML R85 and API 3.1B. The FMR533 is equipped with a parabolic antenna and is especially suitable for measurements in any space within a range of 40 m (131 ft). The Micropilot FMR533 uses a 4-wire cable, HART and 24 VDC intrinsically safe power supply, and is economical and easy to install.

 

Benefits

Accuracy: 0.5 mm (2σ value)

Certified by NMi and PTB national authorities for custody transfer

The system can be used standalone or in combination with tank level measuring systems via the NRF590 tank side monitor

Simple on-site operation via menu-driven alphanumeric display

Convenient commissioning, documentation and fault diagnosis using FDT/DTM technology (FieldCare) software

Probe selected according to the application conditions. A directly installed plate probe is available for conical stilling wells

All probes use the sealed process connection standard (second line of defense)

 

Application areas

With a parabolic antenna, free space can be measured perfectly with a range of up to 40 m (131 ft).

 

Process connection: flange

Temperature range: -40 to +200 °C (-40 to +392 °F)

Pressure range: vacuum to +16 bar (vacuum to +232 psi)

Maximum measuring range: 40 m (131 ft)

Accuracy: less than ±1 mm

C-band: 6 GHz

International explosion protection approval, custody transfer approval, WHG overflow protection, SIL

Spare Parts & Accessories 14

14 spare parts · click to collapse
Order codeDescription
52005936Aluminum coverMaterial: Aluminium for operating + display module VU331 and housing F12/T12 Micropilot M/S, Prosonic M, Levelflex MDetails
518710-0020Cover T3/T12 Alu, coated, gasketMaterial: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231,FMR240/FMR244/ FMR245, FMR250, FMR530/FMR531/FMR532/ FMR533, FMR540, FMU40/FMU41/FMU42.Details
52005643maskcable compartment, electronics side Micropilot M/S, Prosonic M, Levelflex MDetails
71092209O-ringUsage: cover T12/F12/F23.Details
52005586Terminal modulefor housing T12Details
71020581Terminal moduleMicropilot S FMR540Details
XPF0030-*** electronic insert FMR533, Ex, HART, HF moduleEnquire
52026443Display unit VU3314-line alphanumeric display Micropilot M, Micropilot S, Prosonic M, Levelflex MDetails
52005628Seal kitconsists of: 5x O-ring 49.21x3.53 EPDM 5x O-ring 113.9x3.63 EPDM 5x O-ring 72.0x3.0 EPDMDetails
52006335*** Parabolic Reflectorwith screws M6x12Details
71006590High-frequency cableCoax cable dummy antenna for testing the electronics FMR13x, FMR23x, FMR53x, FMP4xDetails
52028063High-frequency cableCoax cable with termination resistor and connection piece dummy antenna FMR13x, FMR23x, FMR53x, FMP4xDetails
52007646Antenna cable removal toolMicropilot M/Micropilot SDetails
71007843ToF Adapter FXA291Usage: connection Micropilot M, Micropilot S, Levelflex M, Prosonic M, Tank Side Monitor, Deltabar S, Cerabar S, Gammapilot M, Micropilot I, to Commubox FXA291.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source: public information from the Endress+Hauser website

Measuring principle video

Click to play
All documents for this model
12 documents · click to expand
BA

操作手册 Micropilot S FMR533 Chinese

Rev. 1413 88 pages
Preview
BA

Micropilot S FMR533 HART Operating Instructions English

HART Rev. 1413 88 pages
Preview
BA

Micropilot S FMR530, FMR531, FMR532, FMR533 HART Description of Instrument Functions English

HART Rev. 1313 84 pages
Preview
BA

Micropilot S FMR530, FMR531, FMR532, FMR533 HART Description of Instrument Functions English

HART Rev. 0409 84 pages
Preview
BA

Micropilot S FMR533 HART English

HART Rev. 0409 102 pages
Preview
TI

技术资料 Micropilot S FMR530 Chinese

Rev. 1413 36 pages
Preview
TI

技术资料 Micropilot S FMR530, FMR532, FMR533 Chinese

Rev. 1310 40 pages
Preview
TI

技术资料 Micropilot S FMR533 Chinese

Rev. 0215 36 pages
Preview
TI

Micropilot S FMR530 Technical Information English

Rev. 1616 36 pages
Preview
TI

Micropilot S FMR530 Technical Information English

Rev. 1516 36 pages
Preview
TI

Micropilot S FMR530 Technical Information English

Rev. 1413 36 pages
Preview
TI

Tankvision NXA820, NXA821, NXA822 English

Rev. 0508 44 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · radar — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted radar properly configured on the existing plant, with the aim of continuous radar level measurement of liquids and solids.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the radar configuration has to involve choosing antenna type by dielectric constant, range and process connection.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing antenna type by dielectric constant, range and process connection, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is reliable under heavy dust and vapour, reducing manual dipping, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · radar — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was continuous radar level measurement of liquids and solids.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing antenna type by dielectric constant, range and process connection.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing antenna type by dielectric constant, range and process connection, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — reliable under heavy dust and vapour, reducing manual dipping, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · radar — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from radar , focusing on continuous radar level measurement of liquids and solids.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The radar specification must therefore cover choosing antenna type by dielectric constant, range and process connection.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing antenna type by dielectric constant, range and process connection, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — reliable under heavy dust and vapour, reducing manual dipping, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · radar — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is radar ; the focus is continuous radar level measurement of liquids and solids.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing antenna type by dielectric constant, range and process connection.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing antenna type by dielectric constant, range and process connection, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means reliable under heavy dust and vapour, reducing manual dipping, which cut the workload on the site maintenance team.