Technical Data
CompareContinuous / Liquids
| Measuring Principle | Level radar |
| Characteristic / Application | Continuous non-contact level measurement for use in high-pressure and high-temperature applications, Horn or planar antenna |
| Specialities | Heartbeat Technology, SIL 2 according to IEC 61508, Bluetooth® commissioning, Operation and maintenance SmartBlue App, Safety and reliability with Multi-Echo Tracking, HistoROM, RFID TAG for easy identification |
| Supply / Communication | 2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus) 4-wire (HART) Bluetooth® wireless technology and App (optional) |
| Frequency | C-band (~6 GHz) |
| Accuracy | +/- 6 mm (0.24 in) |
| Ambient temperature | -50...+80 °C (-58...+176 °F) |
| Process temperature | -60...+400°C (-76...+752°F) |
| Process pressure / max. overpressure limit | Vacuum...160 bar (Vacuum...2320 psi) |
| Main wetted parts | 316L |
| Process connection | Flange: DN80...DN300, ASME 3"...12", JIS 10K, 20K |
| Max. measurement distance | Standard: 20 m (65 ft) Planar antenna in stilling well: 38 m (125 ft) |
| Communication | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus Bluetooth® wireless technology |
| Certificates / Approvals | ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex |
| Safety approvals | Overfill protection WHG SIL |
| Design approvals | EN 10204-3.1 NACE MR0175, MR0103 ASME B31.3 AD2000 |
| Marine approval | GL/ ABS/ LR/ BV/ DNV |
| Options | Display, Customized parameterization, Remote operation via SmartBlue App using Bluetooth®, PWIS free, Gastight feed through |
| Application limits | Maximum measuring range is dependent on the tank form and/or application Free space with nozzle: FMR51, FMR52, FMR53 Stilling well with ball valve: FMR51, FMR52 Hygiene requirements: FMR52, FMR53 316L or Alloy C non-resistant: FMR52, FMR53 |
Micropilot FMR54 is mainly used for level measurement in high-temperature and high-pressure applications; its specially designed flat-face antenna is particularly suitable for level measurement in stilling wells. Micropilot FMR54 is used for continuous, non-contact level measurement of liquids, pastes and slurries. The measured value is unaffected by changes in the medium, temperature changes, gas blanket or vapor.
Benefits
Hardware and software developed in accordance with IEC 61508; a single device meets SIL2, and SIL3 under homogeneous redundancy
HistoROM integrated data storage unit for fast commissioning, maintenance and diagnostics
High measurement reliability based on multi-echo tracking, ensuring accurate measurement even with obstacles in the vessel
Stable and reliable measurement, unaffected by changes in the medium and process conditions
Heartbeat Technology for efficient and safe plant operation throughout the entire life cycle
Seamless integration into control or asset management systems, intuitive menu-guided operating concept (on site or via the control system)
Certified by world-leading SIL and WHG tests, saving time and money
Application
Horn antenna or parabolic (stilling-well) antenna, particularly suitable for horizontal applications.
Process connection: flange
Temperature range: -196 to +400°C (-76 to +752°F)
Pressure range: -1 to +160 bar (-14.5 to +2,320 psi)
Maximum measuring range: 20 m (66 ft)
Accuracy: ±6 mm
C-band: 6 GHz
International explosion protection approvals, WHG overflow protection, SIL, 5-point linearity protocol
Spare Parts & Accessories 76
76 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 71115174 | Housing filter plug 316L, GT18, 1 setConsists of: 2x filter plug metall 316L. 1x pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200. | Details |
| 71115175 | Housing Filter Plug (Brass/Nickel)Consists of: 2x filter plug brass nickel, pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. | Details |
| 71115176 | housing fixing clipUsage: housing GT18/GT19/GT20, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. | Details |
| 71110281 | Aluminum coverMaterial: 316L. O-ring, EPDM, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200. | Details |
| 71383631 | housingMaterial: 316L. O-Ring FVMQ. Usage: FMP51/FMP54, FMR51/FMR52/FMR54. Usage: Prowirl 200. | Details |
| 71110282 | Aluminum coverMaterial: 316L. O-ring NBR, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67, FHX50. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200. | Details |
| 71383666 | housingMaterial: 316L. O-Ring FVMQ. Usage: FMP51/FMP54, FMR51/FMR52/FMR54. Usage: Prowirl 200. | Details |
| 71110284 | Aluminum coverMaterial: 316L. O-ring EPDM /PTFE coated. Usage: terminal compartment Ex d/XP, FMP51/FMP52/FMP54/FMP55/FMP56/FMP57, FMR51/FMR52/FMR53/FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200. | Details |
| 71383670 | housingMaterial: 316L. O-Ring FVMQ. Usage: FMP51/FMP54, FMR51/FMR52/FMR54. Usage: Prowirl 200. | Details |
| 71110291 | Aluminum coverMaterial: 316L. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP51/FMP52/FMP54/FMP55/FMP56/FMP57, FMR51/FMR52/FMR53/FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200. | Details |
| 71383668 | housingMaterial: 316L. O-Ring FVMQ. Usage: FMP51/FMP54, FMR51/FMR52/FMR54. Usage: Prowirl 200. | Details |
| 71110293 | Aluminum coverMaterial: plastics PBT, metallized. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. | Details |
| 71110292 | Aluminum coverMaterial: plastics PBT-FR sight glas PC. O-ring EPDM, PTFE coated. Usage: FHX50, FMP50/FMP51/FMP52/ FMP53/FMP54/FMP55/FMP56/FMP57, FMR50/ FMR51/FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. | Details |
| 71110295 | Aluminum coverMaterial: plastics PBT, metallized. Usage: terminal compartment, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. | Details |
| 71110297 | Aluminum coverMaterial: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. | Details |
| 71383675 | housingMaterial: Alu. O-Ring FVMQ. Usage: FMP51/FMP54, FMR51/FMR52/FMR54. Usage: Prowirl 200. | Details |
| 71110299 | Aluminum coverMaterial: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. | Details |
| 71383674 | housingMaterial: Alu. O-Ring FVMQ. Usage: FMP51/FMP54, FMR51/FMR52/FMR54. Usage: Prowirl 200. | Details |
| 71185516 | CoverMaterial: 316L. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMP54/FMP56/FMP57, FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Prowirl 200. | Details |
| 71383671 | housingMaterial: 316L. O-Ring FVMQ. Usage: FMP51/FMP54, FMR51/FMR52/FMR54. Usage: Prowirl 200. | Details |
Configurator / Comparison
Measuring principle video
Click to playManuals & Documents 8
All documents for this model8 documents · click to expand
Micropilot FMR53, FMR54 HART 操作手册 Chinese
Micropilot FMR53, FMR54 FOUNDATION Fieldbus 操作手册 Chinese
Micropilot FMR53, FMR54 PROFIBUS PA 操作手册 Chinese
Micropilot FMR53, FMR54 HART Operating Instructions English
Micropilot FMR53, FMR54 FOUNDATION Fieldbus Operating Instructions English
Micropilot FMR53, FMR54 PROFIBUS PA Operating Instructions English
TI Micropilot FMR53, FMR54 Chinese
TI Micropilot FMR53, FMR54 English
Product Videos
Case Studies
Municipal Wastewater Treatment · radar — Application Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted radar properly configured on the existing plant, with the aim of continuous radar level measurement of liquids and solids.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the radar configuration has to involve choosing antenna type by dielectric constant, range and process connection.
Configuration
Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing antenna type by dielectric constant, range and process connection, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is reliable under heavy dust and vapour, reducing manual dipping, and the readings are now used for process tuning.
Food & Beverage · radar — Application Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was continuous radar level measurement of liquids and solids.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing antenna type by dielectric constant, range and process connection.
What We Did
We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing antenna type by dielectric constant, range and process connection, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — reliable under heavy dust and vapour, reducing manual dipping, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · radar — Application Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from radar , focusing on continuous radar level measurement of liquids and solids.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The radar specification must therefore cover choosing antenna type by dielectric constant, range and process connection.
Delivery Approach
Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing antenna type by dielectric constant, range and process connection, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — reliable under heavy dust and vapour, reducing manual dipping, with confidence in this measuring point improving markedly.
Power & Energy · radar — Application Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is radar ; the focus is continuous radar level measurement of liquids and solids.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing antenna type by dielectric constant, range and process connection.
Implementation
The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing antenna type by dielectric constant, range and process connection, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means reliable under heavy dust and vapour, reducing manual dipping, which cut the workload on the site maintenance team.
Related Products
Endress+HauserMicropilot FMR20
Endress+HauserMicropilot FMR10
Endress+HauserMicropilot FMR50
Endress+HauserMicropilot FMR56
Endress+HauserMicropilot FMR52
Endress+HauserMicropilot FMR60
Endress+HauserMicropilot FMR57
Endress+Hauser