FMR540 Micropilot SDiscontinued

FMR540 Micropilot S
Micropilot S FMR540Discontinued
Micropilot FMR540 is used for custody transfer and inventory control applications with NMi- and PTB-approvals and meets the requirements according to OIML R85 and API 3.1B. FMR540 with parabolic antenna is particularly suited for free space applications up to 40m and with horn antenna for free space applications that disallow the use of a parabolic antenna due to tank/nozzle geometry. Cost-effective and simple installation via 4-wire cable with HART and 24 V DC intrinsically safe power supply.
Compare

Continuous / Liquids

Measuring Principle Level radar
Characteristic / Application Horn antenna:
High precision measurement for for storage tanks up to 20 m (65ft)
Parabolic antenna:
High precision measurement for free space applications up to 40 m (131 ft)
Supply / Communication 4-wire (HART)
Frequency K-band (~26 GHz)
Accuracy +/- 1 mm
Ambient temperature Standard:
-40°C...80°C
(-40°F...176°F)
For calibration to regulatory standards:
-25°C...60°C
(-13°F...131°F)
Process temperature -40°C...200°C
(-40°F...392°F)
Process pressure / max. overpressure limit Horn: Vacuum...16 bar (232 psi)
Parabolic: Vacuum...6 bar (87 psi)
Use of UNIflange: Vacuum...1 bar (14.5 psi)
Main wetted parts 316L
Process connection Horn Antenna: DN100, DN150 Flange
UNIFlange DN150, DN200, DN250
Parabolic antenna: UNIflange with Top Target
positioner DN200, DN250
For dk value < 1.9, contact Endress+Hauser
Communication 4...20 mA HART
Certificates / Approvals ATEX, FM, CSA, IEC Ex, NEPSI
Application limits Maximum measuring range is dependent on the tank form and/or application
Strong condensate or build-up formation
FMR53x
Existing stilling wells with non-ideal measuring conditions
FMR532

The Micropilot FMR540 is approved by NMi and PTB, can be used for custody transfer and inventory control, and meets the relevant requirements of the R85 and API 3.1B standards. With a parabolic antenna, the FMR540 is especially suitable for measurement in any space within 40 m; with a horn antenna, the FMR540 can be used where the shape of the tank/installation nozzle prevents the use of a parabolic antenna. The Micropilot FMR540 uses a four-wire system, HART and 24 VDC intrinsically safe power supply, and is economical and easy to install.

 

Benefits

  • Accuracy better than 1 mm

  • Custody transfer applications with national certifications (NMi and PTB)

  • The instrument can be used standalone or integrated with a tank level measurement system via the NRF590 tank side indicator

  • Four-wire, HART and 24 V DC intrinsically safe power supply, cost-effective and easy to install.

  • Angle adjustment device compensates for flange inclination

  • Simple on-site operation via menu-driven alphanumeric display module

  • Convenient instrument commissioning, documentation and fault diagnosis using the FieldCare operating software

 

Application areas

The parabolic antenna is suitable for use in any space with a range of up to 40 m, providing highly focused measurement where the nozzle is close to the tank wall, 4"/diameter 100; the horn antenna is suitable for use in any space.

 

  • Process connection: flange

  • Temperature range: -40 to +200 °C (-40 to +392 °F)

  • Pressure range: vacuum to +16 bar (vacuum to +232 psi)

  • Maximum measuring range: 40 m (131 ft)

  • Accuracy: less than ±1 mm

  • K-band: 26 GHz

  • International explosion protection approval, custody transfer approval, WHG overflow protection, SIL

Spare Parts & Accessories 18

18 spare parts · click to collapse
Order codeDescription
52005936Aluminum coverMaterial: Aluminium for operating + display module VU331 and housing F12/T12 Micropilot M/S, Prosonic M, Levelflex MDetails
518710-0020Cover T3/T12 Alu, coated, gasketMaterial: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231,FMR240/FMR244/ FMR245, FMR250, FMR530/FMR531/FMR532/ FMR533, FMR540, FMU40/FMU41/FMU42.Details
71092209O-ringUsage: cover T12/F12/F23.Details
FMR54X1-FMR540 electronic insert, Ex, HART, HF moduleMicropilot SEnquire
71020581Terminal moduleMicropilot S FMR540Details
71020582Terminal moduleMicropilot S FMR540Details
52026443Display unit VU3314-line alphanumeric display Micropilot M, Micropilot S, Prosonic M, Levelflex MDetails
71020169HornMaterial: 316L with fixing screwsDetails
52025233parabolic reflectorwith fixing screws Micropilot M FMR250 Micropilot S FMR540Details
71090287parabolic reflectorFixing screws. DN200/8". Usage: FMR57, FMR540.Details
71090289parabolic reflectorFixing screws. DN250/10". Usage: FMR540, FMR57.Details
52007441Adapter cableConnection > adapter service tool RS232 (016154-0000). To use the ToF-Tool software Micropilot M, Micropilot S, Prosonic M, Levelflex MDetails
52007646Antenna cable removal toolMicropilot M/Micropilot SDetails
71007843ToF Adapter FXA291Usage: connection Micropilot M, Micropilot S, Levelflex M, Prosonic M, Tank Side Monitor, Deltabar S, Cerabar S, Gammapilot M, Micropilot I, to Commubox FXA291.Details
71006590High-frequency cableCoax cable dummy antenna for testing the electronics FMR13x, FMR23x, FMR53x, FMP4xDetails
52028063High-frequency cableCoax cable with termination resistor and connection piece dummy antenna FMR13x, FMR23x, FMR53x, FMP4xDetails
52009925High-frequency test cablecoax cable dummy antenna FMR24x, FMR25x, FMR540Details
52005628Seal kitconsists of: 5x O-ring 49.21x3.53 EPDM 5x O-ring 113.9x3.63 EPDM 5x O-ring 72.0x3.0 EPDMDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Measuring principle video

Click to play
All documents for this model
9 documents · click to expand
BA

操作手册 Micropilot S FMR540 Chinese

Rev. 1514 84 pages
Preview
BA

Micropilot S FMR540 HART Operating Instructions English

HART Rev. 1514 80 pages
Preview
BA

Micropilot S FMR540 HART English

HART Rev. 1414 88 pages
Preview
BA

Micropilot S FMR540 HART English

HART Rev. 0409 84 pages
Preview
BA

Micropilot S FMR540 HART English

HART Rev. 0409 90 pages
Preview
TI

技术资料 Micropilot S FMR540 Chinese

Rev. 1514 40 pages
Preview
TI

技术资料 Micropilot S FMR540 Chinese

Rev. 1310 36 pages
Preview
TI

Micropilot S FMR540 Technical Information English

Rev. 1716 40 pages
Preview
TI

Tankvision NXA820, NXA821, NXA822 English

Rev. 0508 44 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · radar — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted radar properly configured on the existing plant, with the aim of continuous radar level measurement of liquids and solids.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the radar configuration has to involve choosing antenna type by dielectric constant, range and process connection.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing antenna type by dielectric constant, range and process connection, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is reliable under heavy dust and vapour, reducing manual dipping, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · radar — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was continuous radar level measurement of liquids and solids.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing antenna type by dielectric constant, range and process connection.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing antenna type by dielectric constant, range and process connection, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — reliable under heavy dust and vapour, reducing manual dipping, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · radar — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from radar , focusing on continuous radar level measurement of liquids and solids.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The radar specification must therefore cover choosing antenna type by dielectric constant, range and process connection.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing antenna type by dielectric constant, range and process connection, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — reliable under heavy dust and vapour, reducing manual dipping, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · radar — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is radar ; the focus is continuous radar level measurement of liquids and solids.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing antenna type by dielectric constant, range and process connection.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing antenna type by dielectric constant, range and process connection, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means reliable under heavy dust and vapour, reducing manual dipping, which cut the workload on the site maintenance team.