Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FMR63B Micropilot

FMR63B Micropilot
Micropilot FMR63B
Product details for the Micropilot FM63B. 80 GHz level measurement
Compare

Continuous / Liquids

Measuring Principle Level radar
Characteristic / Application Premium device for continuous non-contact level measurement
with hygienic requirements (ASME BPE, USP Class VI);
Specialities Heartbeat Technology,
SIL 2/3 according to IEC 61508,
Bluetooth® commissioning;
Operation and maintenance with SmartBlue app;
HistoROM;
RFID TAG for easy identification;
Very narrow beam angle
Supply / Communication 2-wire (HART/ PROFIBUS PA)
PROFINET with Ethernet-APL
Bluetooth® wireless technology
Frequency W-Band (~80 GHz)
Accuracy +/-1 mm (0.04 in)
Ambient temperature -40 °C … +85 °C (-40 °F … +185 °F)
Process temperature -40 °C … +200 °C (-40 °F … +392 °F)
Process pressure / max. overpressure limit Vacuum...25 bar (363 psi)
Main wetted parts PEEK or PTFE
Process connection Thread:
M24
Process connection hygienic NEUMO BioControl;
Slotted-nut DIN11851;
Varivent;
Tri-Clamp ISO2852
Max. measurement distance 80 m (262 ft)
Communication 4...20 mA HART
Additional analog or switch output
PROFIBUS PA
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional)
Certificates / Approvals IEC Ex, ATEX, CSA C/US, EAC Ex, JPN Ex, KC Ex,
INMETRO Ex, NEPSI Ex, UK Ex;
Safety approvals Overfill protection WHG;
SIL 2/ SIL 3
Design approvals Acceptance test certificate 3.1, EN10204;
EU Food Contact Material (EC) 1935/2004;
US Food Contact Material FDA CFR 21;
Declaration of Conformity ASME B31.3;
Conformity to cGMP;
CoC ASME BPE;
CRN approval
Hygienic approvals 3-A;
EHEDG;
CoC-ASME BPE
Drinking water approvals KTW-BWGL;
NSF/ANSI 61
Options Display,
Customized settings,
App 'SmartBlue' for commissioning and operation via Bluetooth
Gas-tight implementation;
Overvoltage protection;
PWIS free
Application limits Process temp. > 200°C (392°F) -> FMR62
Strong foam, stilling well and bypass (>10 m) -> FMR5x,FMP5x

The Micropilot FMR63B is a member of the new generation 80 GHz radar level meter family. With hygienic process connections, it enables continuous non-contact level measurement in hygienic applications. With a built-in operating wizard, it guides the user easily through commissioning, functional safety and verification tests, making operation very convenient. It uses Heartbeat Technology, supports online self-verification and self-monitoring of the device, promptly detects abnormal conditions, and increases process safety and production efficiency.

Advantages
Intuitive human-machine interface with guided device commissioning and verification wizards for simple operation

  • Uses Heartbeat Technology, supports online self-monitoring, self-verification and self-diagnosis of the device, increasing productivity

  • Safety design concept, developed in accordance with IEC 61508

  • The device status is shown on the display and immediately switches from green to red if an error occurs

  • The device uses digital communication for easy integration into asset management systems

Field of application
The Micropilot FMR63B is suitable for level measurement in free space with a maximum range of 80 m and offers excellent beam focusing for tanks with interfering installations inside.

  • Process connection: M24 adapter and hygienic process connection

  • Process temperature: –40...+200°C (-40...+392°F)

  • Process pressure: –1...+25 bar (-14.5...+362.6 psi)

  • Maximum range: 80 m (164 ft)

  • Measuring accuracy: ±1 mm (0.04 in)

  • W-band: 80 GHz operating frequency

  • International explosion protection certification, WHG overflow certification, SIL certification, and 5-point or 10-point factory calibration

 

Spare Parts & Accessories 99

99 spare parts · click to collapse
Order codeDescription
71487198Blind plug, M20, 316L, O-ring EPDMConsists of: blind plug, O-ring PTFE coated 17.0x2.0. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71487199Plug: M20, aluminum, EPDM sealing ringConsists of: blind plug, O-ring PTFE coated 17.0x2.0. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71679712Blind plug M20, 316L, Ex dConsists of: Plug IEC/ATEX Ex d marking o-ring PTFE coated 17,0x2,0. Usage: FMG50, FMP51, FMP52, FMP54, FMP55, FMP56, FMP57, FMR51, FMR52, FMR53, FMR54, FMR57, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL62, FTL64, OFMP51, OFMP57, OFMR51,OFMR54, OFTL51B, PMC71B, PMD50, PMD75B, PMD78B, PMP50, PMP71B.Details
71679714Blind plug M20, Alu, Ex dConsists of: Plug IEC/ATEX Ex d marking, o-ring PTFE coated 17,0x2,0. Usage: FMG50, FMP51, FMP52, FMP54, FMP55, FMP56, FMP57, FMR51, FMR52, FMR53, FMR54, FMR57, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, OFMP50, OFMP51, OFMP57, OFMR51, OFMR54, OFTL41, OFTL51B, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71487201Blind plug, NPT1/2, aluminumConsists of: blind plug, PTFE coated. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71487203Blind plug, NPT1/2, 316LConsists of: blind plug, PTFE coated. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71679715Blind plug NPT1/2, 316L, Ex dConsists of: Plug IEC/ATEX Ex d marking, PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, PMC71B, PMD50, PMD75B, PMD78B, PMP71B, PMP50.Details
71679718Blind plug NPT1/2, Alu, Ex dConsists of: Plug IEC/ATEX Ex d marking, PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71435135Cable gland M20, plastic, suitable for models: FTL41, FTL51B, PMC51B, PConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMB70, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD63B, PMD75B, PMD78B, PMP50, PMP51B, PMP63B, PMP71B.Details
71435136Cable gland M20, nickel-plated brass, suitable for: FMG50, FTL41, FTL51B, PConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71435137Cable gland M20, 316L, suitable for models: FMG50, FTL51B, PMC51BConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71471535Cable gland M20x1.5 x G1/2, Ex d, brassOnly for Japanese market. Consists of: Cable gland M20x1.5 x G1/2 Ms/Ni. Usage: FMG50, FMP51, FMP52, FMP53, FMP54, FMP55, FMP56, FMP57, FMR50, FMR51, FMR52, FMR53, FMR54, FMR56, FMR57, FMR60, FMR62, FMR67, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, NMR81, NMR84, NMS80, NMS81, NMS83, NRF81, PMC51B, PMP51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP71B.Details
71440660M20x1.5-G1/2 adapter, aluminumConsists of: Adapter set, O-ring, 17.0 x 2.0 PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71440667M20x1.5-G1/2 adapter, 316LConsists of: Adapter, O-Ring 17.0 x 2.0 PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71435138Plug connector M20, nickel-plated brass, suitable for: screw-in thread, FMG50Usage: M12 screw-in thread, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71435139M12 plug, 316L, APL, housing sideUsage: M12 screw-in thread. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64, FTM50, FTM51, FTM52, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71439098Connector HAN7D, 90°, IP65, suitable for: FMG50, PMC51BUsage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71474251Enclosure grounding terminal L+PConsists of: spring washer, screw, earth handle, clamp. Usage Liquiphant: Only for digital communication. Usage: FHX50B, FMG50, PMD50, PMD55B, PMD63B, PMD75B, PMD78B, PMC51B, PMC71B, PMP50, PMP51B, PMP63B, PMP71B, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64.Details
71589861Ground terminal plastic housing L+PConsists of: spring, washer, clamp. Usage Liquiphant: For digital communication only Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B.Details
71647974Ground terminal hygiene housing L+PConsists of: spring washer, screw, clamp strap. Usage Liquiphant: Only for digital communication. Usage: FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
All documents for this model
12 documents · click to expand
BA

BA Micropilot FMR63B Chinese

Rev. 0725 88 pages
Preview
BA

BA Micropilot FMR63B PROFIBUS PA Chinese

PROFIBUS-PA Rev. 0425 84 pages
Preview
BA

BA Micropilot FMR63B PROFINET + Ethernet-APL Chinese

PROFINET Rev. 0324 92 pages
Preview
BA

BA Micropilot FMR63B English

Rev. 0725 92 pages
Preview
BA

BA Micropilot FMR63B PROFIBUS PA English

PROFIBUS-PA Rev. 0425 88 pages
Preview
BA

BA Micropilot FMR63B PROFINET over Ethernet-APL English

PROFINET Rev. 0324 96 pages
Preview
TI

TI 焊接接头、过程转接头和法兰 Chinese

Rev. 2726 130 pages
Preview
TI

TI Micropilot FMR63B HART Chinese

HART Rev. 0724 80 pages
Preview
TI

TI Micropilot FMR63B PROFIBUS PA Chinese

PROFIBUS-PA Rev. 0525 72 pages
Preview
TI

TI Micropilot FMR63B PROFINET + Ethernet-APL Chinese

PROFINET Rev. 0424 72 pages
Preview
TI

TI Weld-in adapter, process adapter and flanges English

Rev. 2726 132 pages
Preview
TI

TI Micropilot FMR63B HART English

HART Rev. 0724 84 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · radar — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted radar properly configured on the existing plant, with the aim of continuous radar level measurement of liquids and solids.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the radar configuration has to involve choosing antenna type by dielectric constant, range and process connection.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing antenna type by dielectric constant, range and process connection, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is reliable under heavy dust and vapour, reducing manual dipping, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · radar — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was continuous radar level measurement of liquids and solids.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing antenna type by dielectric constant, range and process connection.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing antenna type by dielectric constant, range and process connection, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — reliable under heavy dust and vapour, reducing manual dipping, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · radar — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from radar , focusing on continuous radar level measurement of liquids and solids.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The radar specification must therefore cover choosing antenna type by dielectric constant, range and process connection.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing antenna type by dielectric constant, range and process connection, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — reliable under heavy dust and vapour, reducing manual dipping, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · radar — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is radar ; the focus is continuous radar level measurement of liquids and solids.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing antenna type by dielectric constant, range and process connection.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing antenna type by dielectric constant, range and process connection, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means reliable under heavy dust and vapour, reducing manual dipping, which cut the workload on the site maintenance team.