Configurable Models 6 models
Product details for the Micropilot FMR66B. 80 GHz level measurement
Compare

Continuous / Solids

Measuring Principle Level radar solid
Characteristic / Application For simple applications:
Reliable, non-contact measurement of levels
in silos or storage tanks for bulk solids
Specialities Heartbeat Verification + Monitoring, Bluetooth® Commissioning,
operation and maintenance with SmartBlue App,
HistoROM, RFID TAG for easy identification
Supply / Communication 2-wire (HART/ PROFIBUS PA)
PROFINET with Ethernet-APL
Bluetooth® wireless technology
Frequency W-Band (~80 GHz)
Antenna 1-1/2" / 40mm encapsulated, PVDF
2" / 50mm Drip-off, PTFE
Accuracy +/- 3 mm (0.12 in)
Ambient temperature -40 … +85 °C (-40 … +185 °F)
Process temperature -40 … +130 °C (-40 … +266 °F)
Process pressure / max. overpressure limit Vacuum...16 bar (232 psi)
Main wetted parts PVDF or PTFE
Process connection Thread:
G1-1/2", MNPT1-1/2"
Flange:
UNI DN80...DN150
Mounting bracket
Max. measurement distance 50 m (164 ft)
Communication 4...20 mA HART
Additional analog or switch output
PROFIBUS PA
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional)
Certificates / Approvals IEC Ex, ATEX, CSA C/US, EAC Ex, JPN Ex,
KC Ex, INMETRO Ex, NEPSI Ex, UK Ex
Safety approvals SIL
Design approvals Declaration of Conformity ASME B31.3;
CRN approval
Hygienic approvals EU Food Contact Material (EC) 1935/2004
US Food Contact Material FDA CFR 21
Marine approval ABS, LR, BV, RINA, DNV
Options Display, Customized settings,
App 'SmartBlue' for commissioning and operation via Bluetooth
Heartbeat for batch detection; Gas-tight implementation;
Overvoltage protection; PWIS free
Application limits DK < 1.6
Reduction of the max. possible measuring range due to:
Media with poor reflective properties cone of repose
extremely loose surface of bulk solids, e.g. bulk solids with a
low bulk density during pneumatic filling buildup, especially of
moist products.
Alternative for these applications: FMR67B

The Micropilot FMR66B is a member of the new generation 80 GHz radar level meter family. It performs continuous non-contact level measurement in basic solid applications. With a built-in operating wizard, it guides the user easily through commissioning, functional safety and verification tests, making operation very convenient. The small beam angle makes it particularly suitable for installation in narrow silos. It uses Heartbeat Technology, supports online self-verification and self-monitoring of the device, promptly detects abnormal conditions, and increases process safety and production efficiency.

Advantages
Intuitive human-machine interface with guided device commissioning and verification wizards for simple operation

  • Recommended actions are displayed on the display, helping the user to troubleshoot easily

  • Safety design concept, developed in accordance with IEC 61508

  • Uses Heartbeat Technology, supports online self-monitoring, self-verification and self-diagnosis of the device, increasing productivity

  • The device uses digital communication for easy integration into asset management systems

Field of application
The Micropilot FMR66B is suitable for level measurement in free space with a maximum range of 50 m and offers excellent beam focusing for tanks with interfering installations inside.

  • Process connection: thread or mounting bracket

  • Process temperature: –40...+200°C (–40...+392°F)

  • Process pressure: –1...+16 bar (–14.5...+266 psi)

  • Maximum range: 50 m (164 ft)

  • Measuring accuracy: ±3 mm (0.12 in)

  • W-band: 80 GHz operating frequency

  • International explosion protection certification, SIL certification, marine classification, and 5-point or 10-point factory calibration

 

Spare Parts & Accessories 82

82 spare parts · click to collapse
Order codeDescription
71487198Blind plug, M20, 316L, O-ring EPDMConsists of: blind plug, O-ring PTFE coated 17.0x2.0. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71487199Plug: M20, aluminum, EPDM sealing ringConsists of: blind plug, O-ring PTFE coated 17.0x2.0. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71679712Blind plug M20, 316L, Ex dConsists of: Plug IEC/ATEX Ex d marking o-ring PTFE coated 17,0x2,0. Usage: FMG50, FMP51, FMP52, FMP54, FMP55, FMP56, FMP57, FMR51, FMR52, FMR53, FMR54, FMR57, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL62, FTL64, OFMP51, OFMP57, OFMR51,OFMR54, OFTL51B, PMC71B, PMD50, PMD75B, PMD78B, PMP50, PMP71B.Details
71679714Blind plug M20, Alu, Ex dConsists of: Plug IEC/ATEX Ex d marking, o-ring PTFE coated 17,0x2,0. Usage: FMG50, FMP51, FMP52, FMP54, FMP55, FMP56, FMP57, FMR51, FMR52, FMR53, FMR54, FMR57, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, OFMP50, OFMP51, OFMP57, OFMR51, OFMR54, OFTL41, OFTL51B, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71487201Blind plug, NPT1/2, aluminumConsists of: blind plug, PTFE coated. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71487203Blind plug, NPT1/2, 316LConsists of: blind plug, PTFE coated. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71679715Blind plug NPT1/2, 316L, Ex dConsists of: Plug IEC/ATEX Ex d marking, PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, PMC71B, PMD50, PMD75B, PMD78B, PMP71B, PMP50.Details
71679718Blind plug NPT1/2, Alu, Ex dConsists of: Plug IEC/ATEX Ex d marking, PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71435135Cable gland M20, plastic, suitable for models: FTL41, FTL51B, PMC51B, PConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMB70, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD63B, PMD75B, PMD78B, PMP50, PMP51B, PMP63B, PMP71B.Details
71701449Cable gland, blue, M20, plasticConsists of: Cable gland blue M20x1.5, PA, O-ring 17.0 x 2.0 PTFE coated. Usage: FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71435136Cable gland M20, nickel-plated brass, suitable for: FMG50, FTL41, FTL51B, PConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71435137Cable gland M20, 316L, suitable for models: FMG50, FTL51B, PMC51BConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71471535Cable gland M20x1.5 x G1/2, Ex d, brassOnly for Japanese market. Consists of: Cable gland M20x1.5 x G1/2 Ms/Ni. Usage: FMG50, FMP51, FMP52, FMP53, FMP54, FMP55, FMP56, FMP57, FMR50, FMR51, FMR52, FMR53, FMR54, FMR56, FMR57, FMR60, FMR62, FMR67, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, NMR81, NMR84, NMS80, NMS81, NMS83, NRF81, PMC51B, PMP51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP71B.Details
71440660M20x1.5-G1/2 adapter, aluminumConsists of: Adapter set, O-ring, 17.0 x 2.0 PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71440667M20x1.5-G1/2 adapter, 316LConsists of: Adapter, O-Ring 17.0 x 2.0 PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71435138Plug connector M20, nickel-plated brass, suitable for: screw-in thread, FMG50Usage: M12 screw-in thread, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71435139M12 plug, 316L, APL, housing sideUsage: M12 screw-in thread. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64, FTM50, FTM51, FTM52, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71439098Connector HAN7D, 90°, IP65, suitable for: FMG50, PMC51BUsage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71474251Enclosure grounding terminal L+PConsists of: spring washer, screw, earth handle, clamp. Usage Liquiphant: Only for digital communication. Usage: FHX50B, FMG50, PMD50, PMD55B, PMD63B, PMD75B, PMD78B, PMC51B, PMC71B, PMP50, PMP51B, PMP63B, PMP71B, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64.Details
71589861Ground terminal plastic housing L+PConsists of: spring, washer, clamp. Usage Liquiphant: For digital communication only Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
6 models · click to collapse
All documents for this model
12 documents · click to expand
BA

BA Micropilot FMR66B Chinese

Rev. 0625 76 pages
Preview
BA

BA Micropilot FMR66B PROFIBUS PA Chinese

PROFIBUS-PA Rev. 0325 72 pages
Preview
BA

BA Micropilot FMR66B PROFINET + Ethernet-APL Chinese

PROFINET Rev. 0224 80 pages
Preview
BA

BA Micropilot FMR66B English

Rev. 0625 84 pages
Preview
BA

BA Micropilot FMR66B PROFIBUS PA English

PROFIBUS-PA Rev. 0325 76 pages
Preview
BA

BA Micropilot FMR66B PROFINET over Ethernet-APL English

PROFINET Rev. 0224 84 pages
Preview
TI

TI Micropilot FMR66B HART Chinese

HART Rev. 0524 60 pages
Preview
TI

TI Micropilot FMR66B PROFIBUS PA Chinese

PROFIBUS-PA Rev. 0325 56 pages
Preview
TI

TI Micropilot FMR66B PROFINET + Ethernet-APL Chinese

PROFINET Rev. 0224 56 pages
Preview
TI

TI Micropilot FMR66B HART English

HART Rev. 0524 64 pages
Preview
TI

TI Micropilot FMR66B PROFIBUS PA English

PROFIBUS-PA Rev. 0325 56 pages
Preview
TI

TI Micropilot FMR66B PROFINET over Ethernet-APL English

PROFINET Rev. 0224 60 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · radar — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted radar properly configured on the existing plant, with the aim of continuous radar level measurement of liquids and solids.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the radar configuration has to involve choosing antenna type by dielectric constant, range and process connection.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing antenna type by dielectric constant, range and process connection, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is reliable under heavy dust and vapour, reducing manual dipping, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · radar — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was continuous radar level measurement of liquids and solids.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing antenna type by dielectric constant, range and process connection.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing antenna type by dielectric constant, range and process connection, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — reliable under heavy dust and vapour, reducing manual dipping, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · radar — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from radar , focusing on continuous radar level measurement of liquids and solids.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The radar specification must therefore cover choosing antenna type by dielectric constant, range and process connection.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing antenna type by dielectric constant, range and process connection, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — reliable under heavy dust and vapour, reducing manual dipping, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · radar — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is radar ; the focus is continuous radar level measurement of liquids and solids.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing antenna type by dielectric constant, range and process connection.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing antenna type by dielectric constant, range and process connection, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means reliable under heavy dust and vapour, reducing manual dipping, which cut the workload on the site maintenance team.