Product family:
Micropilot FMR67B
Micropilot FMR67B
Micropilot FMR67B;Approval NEPSI Ex ia IIC T6 Ga/Gb;Output 2-wire 4-20mA HART;Display/Operation Graphic display with touch control;Housing/Material Single compartment; Alu, coated;Electrical Connection Gland M20, plastic, IP66/68 NEMA Type 4X/6P;Application Process temperature -40…150oC/ -40...302oF;Antenna Flush mount, PTFE, 80mm/3";Process Connection, Sealing Surface Flange EN1092-1, B1;Process Connection DN100 PN10/16, 316L;Seal FKM Viton GLT;Air Purge Connection G1/4;Oper
Order Code:FMR67B-NBBAEBAJGPEBETJD1+AK
Name:Micropilot FMR67B
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | NB | NEPSI Ex ia IIC T6 Ga/Gb |
| 020 | Output | BA | 2-wire 4-20mA HART |
| 030 | Display; Operation | E | Graphic display with touch control |
| 040 | Housing; Material | B | Single compartment; Alu, coated |
| 050 | Electrical Connection | A | Gland M20, plastic, IP66/68 NEMA Type 4X/6P |
| 060 | Application | J | Process temperature -40…150oC/ -40...302oF |
| 070 | Antenna | GP | Flush mount, PTFE, 80mm/3" |
| 105 | Process Connection, Sealing Surface | EB | Flange EN1092-1, B1 |
| 110 | Process Connection | ETJ | DN100 PN10/16, 316L |
| 200 | Seal | D | FKM Viton GLT |
| 210 | Air Purge Connection | 1 | G1/4 |
| 500 | Operation Language Display | AK | Chinese simplified |
Related Products
Endress+HauserMicropilot FMR20
View →
Endress+HauserMicropilot FMR10
View →
Endress+HauserMicropilot FMR50
View →
Endress+HauserMicropilot FMR56
View →
Endress+HauserMicropilot FMR52
View →
Endress+HauserMicropilot FMR60
View →
Endress+HauserMicropilot FMR57
View →
Endress+HauserMicropilot FMR62
View →