FTG20 Gammapilot
Gammapilot FTG20
The Gammapilot FTG20 is the world’s most advanced Geiger-Mueller counter with highest available sensitivity and outstanding features. Even under extreme process conditions like high pressure, high temperature, corrosiveness, toxicity and abrasion, the radiometric measuring principle can be employed without any problems.
Compare

Point Level / Liquids

Measuring Principle Radiometric Limit
Characteristic / Application Radiometric Transmitter with 1 to 3 Geiger-Müller counters for contactless measurement in liquids, sludge or suspensions under exteme process conditions
Specialities Calculation and sizing with Applicator
Supply / Communication Relay DPDT:
19...253VAC, 19...55VDC
8/16mA:
11...36VDC, 11..30VDC (Exia)
Ambient temperature Relay DPDT:
19...253VAC, 19...55VDC
8/16mA:
11...36VDC, 11..30VDC (Exia)
Process temperature Any
Process pressure / max. overpressure limit Any
Min. density of medium Any
Min. conductivity of medium Any
Main wetted parts Non-contact
Process connection Non-contact
Process connection hygienic Non-contact
Sensor length 140 mm (5.5")
Communication Relay DPDT
8/16mA
4...20mA
Certificates / Approvals ATEX, CSA, CSA C/US, IEC Ex, NEPSI, EAC
Options Sensitivity:
1x Geiger- counter: 1-8uSv/h,
2x Geiger- counter: 0,5-4uSv/h
3x Geiger- counter: 0,3-2,7uSv/h
Cooling jacket
Transmitter with compartment for conduit
Components Isotope: FSG60, FSG61
Source container: FQG60, FQG61, FQG62, FQG63, QG2000

Point Level / Solids

Measuring Principle Radiometric Limit
Characteristic / Application Radiometric Transmitter with 1 to 3 Geiger-Müller counters for contactless measurement in solids under exteme process conditions
Specialities Calculation and sizing with Applicator
Supply / Communication Relay DPDT:
19...253VAC, 19...55VDC
8/16mA:
11...36VDC, 11..30VDC (Exia)
Ambient temperature -40...70°C,
(-40...158°F),
With cooling jacket:
0...120°C
(32...248°F)
Process temperature Any
Process pressure / max. overpressure limit Any
Min. density of medium Any
Main wetted parts Non-contact
Process connection Non-contact
Process connection hygienic Non-contact
Sensor length 140 mm (5.5")
Communication Relay DPDT
8/16mA
4...20mA
Certificates / Approvals ATEX, CSA C/US, IEC Ex, NEPSI, EAC
Options Sensitivity:
1x Geiger- counter: 1-8uSv/h,
2x Geiger- counter: 0,5-4uSv/h
3x Geiger- counter: 0,3-2,7uSv/h
Cooling jacket
Transmitter with compartment for conduit
Components Isotope: FSG60, FSG61
Source container: FQG60, FQG61, FQG62, FQG63, QG2000

The Gammapilot FTG20 is the most advanced Geiger—Müller counter in the world, with high sensitivity and outstanding characteristics. Even under the most extreme process conditions, such as high pressure, high temperature, corrosion, toxicity and abrasion, the radiometric measuring principle can be used without any measurement problems.

Advantages
Sensor and transmitter: a single device for all measuring tasks

  • Maintains the highest suitability, reliability and safety even under the most extreme process and environmental conditions.

  • Sensors with different sensitivities can be selected to optimize the setting for different applications and measuring ranges

  • Relay: 8/16 mA (passive) or 4~20 mA output for easy system integration

  • Available with aluminum or stainless steel housing, suitable for demanding applications.

  • Simple commissioning and fast on-site operation.

  • Numerous certifications and approvals for a wide range of use.

Field of application
Non-intrusive point level detection of liquids, solids, suspensions and sludge. It can be used for measurement under extreme conditions such as high pressure, high temperature, corrosion, toxicity and abrasion, and is suitable for various process vessels such as reactors, autoclaves, separators, acid tanks, mixers, cyclones and blast furnaces.

Spare Parts & Accessories 27

27 spare parts · click to collapse
Order codeDescription
71186946CoverO-ring EPDM. Usage: housing F27 316L, FTG20.Details
71186947CoverO-ring EPDM. Usage: housing F13 aluminium, FTG20.Details
71186948CoverO-ring EPDM. Usage: housing F13 aluminium, FTG20.Details
71186964Aluminum coverO-ring EPDM/PTFE. Usage: connection compartment sensor, aluminium housing, FTG20.Details
71186965Stainless Steel CoverO-ring EPDM/PTFE. Usage: connection compartment sensor, housing 316L, FTG20.Details
71186966gasketO-ring 75.87x 2.62 EPDM/PTFE. Usage: sensor housing FTG20.Details
52004277Seal kitconsists of: 10x O-ring 70,0x3,0 EPDMDetails
XPF0019-electronic plug-in moduleUsage: FTG20.Enquire
71186950electronic plug-in moduleConsists of: sensor assembly. 1 counter tube. O-ring EPDM/PTFE. Cylinder head screw M4x14, 3 pieces. Set screw M4x6.2 pieces. Usage: FTG20.Details
71186951electronic plug-in moduleConsists of: sensor assembly. 2 counter tube. O-ring EPDM/PTFE. Cylinder head screw M4x14, 3 pieces. Set screw M4x6.2 pieces. Usage: FTG20.Details
71186952electronic plug-in moduleConsists of: sensor assembly. 3 counter tube. O-ring EPDM/PTFE. Cylinder head screw M4x14, 3 pieces. Set screw M4x6.2 pieces. Usage: FTG20.Details
71186953Cable L=5m/200inch, 2x M23, cinkConnection cable sensor >transmitter. Plug both side M23 cink. Standard version. Usage: FTG20.Details
71186954Cable L=10m/400inch, 2x M23, cinkConnection cable sensor >transmitter. Plug both side M23 cink. Standard version. Usage: FTG20.Details
71186955Cable L=20m/800inch, 2x M23, cinkConnection cable sensor >transmitter. Plug both side M23 cink. Standard version. Usage: FTG20.Details
71186956Cable l=5m/200inch, 2x M23, 316LConnection cable sensor >transmitter. Plug both side M23 316L. High temperature version. Usage: FTG20.Details
71186957Cable l=10m/400inch, 2x M23, 316LConnection cable sensor >transmitter. Plug both side M23 316L. High temperature version. Usage: FTG20.Details
71186958Cable l=20m/800inch, 2x M23, 316LConnection cable sensor >transmitter. Plug both side M23 316L. High temperature version. Usage: FTG20.Details
71186959Cable l=5m/200inch, 1x M23, 316LConnection cable sensor > transmitter. Plug M23 316L. 1x unconnected cable end > connection compartment. High temperature version. Usage: FTG20.Details
71186960Cable l=10m/400inch, 1x M23, 316LConnection cable sensor > transmitter. Plug M23 316L. 1x unconnected cable end > connection compartment. High temperature version. Usage: FTG20.Details
71186963Cable L=20m/800inch, 1x M23, 316LConnection cable sensor > transmitter. Plug M23 316L. 1x unconnected cable end > connection compartment. High temperature version. Usage: FTG20.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserpublic information from the website

All documents for this model
3 documents · click to expand
BA

Gammapilot FTG20 操作手册 Chinese

Rev. 0212 52 pages
Preview
BA

Gammapilot FTG20 English

Rev. 0212 52 pages
Preview
TI

Gammapilot FTG20 English

Rev. 0212 32 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · radiant — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was non-contact level measurement in extreme duty using radiometric principles.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means sizing source strength against wall thickness, density and licensing requirements.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around sizing source strength against wall thickness, density and licensing requirements, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — measurable under high temperature, pressure and corrosion without intruding into the vessel, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · radiant — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from radiant, focusing on non-contact level measurement in extreme duty using radiometric principles.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The radiant specification must therefore cover sizing source strength against wall thickness, density and licensing requirements.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on sizing source strength against wall thickness, density and licensing requirements, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — measurable under high temperature, pressure and corrosion without intruding into the vessel, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · radiant — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is radiant; the focus is non-contact level measurement in extreme duty using radiometric principles.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with sizing source strength against wall thickness, density and licensing requirements.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on sizing source strength against wall thickness, density and licensing requirements, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means measurable under high temperature, pressure and corrosion without intruding into the vessel, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · radiant — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on radiant and the core task is non-contact level measurement in extreme duty using radiometric principles.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So radiant cannot be specified generically — it calls for sizing source strength against wall thickness, density and licensing requirements.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves sizing source strength against wall thickness, density and licensing requirements, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is measurable under high temperature, pressure and corrosion without intruding into the vessel.