Technical Data
CompareSoftware
| Measuring Principle | Inventory Management Solutions |
| Application Task | Data acquisition Data management Process monitoring & visualization |
| Field of Application | Tankvision LMS NXA86B is a on-premise software for installation on a single station or server client system for monitoring of level, volumes, mass and energy content specifically for LNG tanks in storage facilities. |
| Operating systems | Single Station or Client System: Windows 10 Windows 11 Server System: Windows Server 2025 |
| Processor type | Single Station or Client System: Multi-core processor (e.g. Intel Core i7 or equivalent) Server System: Multi-core (4, 6, or 8) processor (e.g. Intel E5 Xeon) |
| Main memory | Single Station or Client System: 8 GB Server System: 16 GB (32+ GB if used as a virtual host) |
| Hard-disk capacity | Single Station or Client System: 500+ GB Server System: Dual 500+ GB minimum, RAID recommended |
| Monitor resolution, display | 1920 x 1080 (or better) |
| Interfaces | OPC classic OPC UA Modbus |
Tankvision LMS NXA86B LNG tank gauging system
Advantages
Standalone or redundant system architecture
Intuitive, user-friendly graphical user interface (GUI) supporting typical LNG tank instrumentation: servo, radar, LTD, skin temperature, etc.
Stratification and rollover prediction
Automatic composition analysis
Field of application
Tankvision LMS is an LNG tank storage and management solution for peak-shaving plants, receiving terminals and LNG production facilities. It is designed to interface with all instrumentation and to collect and present instrument data via a series of intuitive graphical user interfaces. A typical LNG tank has a wide range of measuring instruments for measuring level, liquid density, liquid and vapor temperature, liquid and vapor pressure, skin temperature, etc.
Tankvision LMS NXA86B is an LNG tank gauging system for peak-shaving plants, receiving terminals and LNG production facilities.
Seamless integration of all major types of tank level, temperature and density/mass measuring instruments
Continuous calculation and display of parameters such as level, temperature, pressure, density, mass, flow, total volume and standard volume
”Stratification and rollover prediction
Automatic composition analysis
Configurator / Comparison
Technical documentation
Accessories/Spare parts
Source:Endress+Hauserpublic information from the website
Manuals & Documents 12
All documents for this model12 documents · click to expand
BA Tankvision LMS NXA86B Chinese
BA Tankvision LMS NXA86B Chinese
BA Tankvision LMS NXA86B Chinese
BA Tankvision LMS NXA86B Chinese
BA Tankvision Professional NXA85 Tankvision LMS NXA86B English
BA Tankvision Professional NXA85 Tankvision LMS NXA86B English
BA Tankvision NXA85, NXA86B Terminalvision NXS85 English
Tankvision Professional NXA85 / Tankvision LMS NXA86 English
BA Tankvision Professional NXA85 Tankvision LMS NXA86B Terminalvision NXS85 English
BA Tankvision LMS NXA86B English
BA Tankvision Professional NXA85 Tankvision LMS NXA86B English
Tankvision Professional NXA85 / Tankvision LMS NXA86 English
Case Studies
Municipal Wastewater Treatment · data manager — Application Case
Site Conditions
This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was centralised data acquisition, storage and forwarding to management platforms.
The Problem
The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means selected by channel count, storage depth and forwarding protocol.
What We Did
We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around selected by channel count, storage depth and forwarding protocol, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.
Operating Outcome
In service the system performs as intended — automatic backfill after outages, greatly improving data completeness, with routine maintenance falling noticeably.
Food & Beverage · data manager — Application Case
Application Context
dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from data manager, focusing on centralised data acquisition, storage and forwarding to management platforms.
Process Constraints
frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The data manager specification must therefore cover selected by channel count, storage depth and forwarding protocol.
Delivery Approach
Delivery was handled as the system components range — supplying as a full cabinet and signal-chain configuration. Execution centred on selected by channel count, storage depth and forwarding protocol, together with food-safety and hygienic design per 3-A / EHEDG.
Field Results
Operation shows the benefit clearly — automatic backfill after outages, greatly improving data completeness, with confidence in this measuring point improving markedly.
Chemical & Pharmaceutical · data manager — Application Case
Customer Profile
The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is data manager; the focus is centralised data acquisition, storage and forwarding to management platforms.
Key Difficulties
Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with selected by channel count, storage depth and forwarding protocol.
Implementation
The scope ran through the system components range: supplying as a full cabinet and signal-chain configuration. Technically it hinges on selected by channel count, storage depth and forwarding protocol, and on these requirements: Ex certification and GMP traceability of records.
Customer Benefit
In practice this means automatic backfill after outages, greatly improving data completeness, which cut the workload on the site maintenance team.
Power & Energy · data manager — Application Case
Project Background
The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on data manager and the core task is centralised data acquisition, storage and forwarding to management platforms.
Operating Challenges
The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So data manager cannot be specified generically — it calls for selected by channel count, storage depth and forwarding protocol.
Solution
The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves selected by channel count, storage depth and forwarding protocol, with these requirements in view: compliance with power-industry codes and unit availability targets.
Results
Since start-up the system has run steadily; the practical result is automatic backfill after outages, greatly improving data completeness.
Related Products
Endress+HauserEngyCal RH33
Endress+HauserAdvanced Graphic Data Manager RSG45
Endress+HauserEnergy Manager RMC621
Endress+HauserSteam- and Heat computer RMS621
Endress+HauserEcograph T RSG35
Endress+HauserBatch Controller RA33
Endress+HauserField Data Manager Software MS21
Endress+Hauser