Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

NXA86B Tankvision LMS

NXA86B Tankvision LMS
Tankvision LMS NXA86B
Tankvision LMS NXA86B LNG tank gauging system AdvantagesStandalone or redundant system architectureIntuitive, user-friendly graphical user interface (GUI) supporting typical LNG tank instrumentation: …
Compare

Software

Measuring Principle Inventory Management Solutions
Application Task Data acquisition
Data management
Process monitoring & visualization
Field of Application Tankvision LMS NXA86B is a on-premise software for installation on a single station or server client system for monitoring of level, volumes, mass and energy content specifically for LNG tanks in storage facilities.
Operating systems Single Station or Client System:
Windows 10
Windows 11
Server System:
Windows Server 2025
Processor type Single Station or Client System:
Multi-core processor (e.g. Intel Core i7 or equivalent)
Server System:
Multi-core (4, 6, or 8) processor (e.g. Intel E5 Xeon)
Main memory Single Station or Client System:
8 GB
Server System:
16 GB (32+ GB if used as a virtual host)
Hard-disk capacity Single Station or Client System:
500+ GB
Server System:
Dual 500+ GB minimum, RAID recommended
Monitor resolution, display 1920 x 1080 (or better)
Interfaces OPC classic
OPC UA
Modbus

Tankvision LMS NXA86B LNG tank gauging system
Advantages
Standalone or redundant system architecture
Intuitive, user-friendly graphical user interface (GUI) supporting typical LNG tank instrumentation: servo, radar, LTD, skin temperature, etc.
Stratification and rollover prediction
Automatic composition analysis
Field of application
Tankvision LMS is an LNG tank storage and management solution for peak-shaving plants, receiving terminals and LNG production facilities. It is designed to interface with all instrumentation and to collect and present instrument data via a series of intuitive graphical user interfaces. A typical LNG tank has a wide range of measuring instruments for measuring level, liquid density, liquid and vapor temperature, liquid and vapor pressure, skin temperature, etc.
Tankvision LMS NXA86B is an LNG tank gauging system for peak-shaving plants, receiving terminals and LNG production facilities.
Seamless integration of all major types of tank level, temperature and density/mass measuring instruments
Continuous calculation and display of parameters such as level, temperature, pressure, density, mass, flow, total volume and standard volume
”Stratification and rollover prediction
Automatic composition analysis

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

Technical documentation

  

 

 

Accessories/Spare parts

 

Source:Endress+Hauserpublic information from the website

All documents for this model
12 documents · click to expand
BA

BA Tankvision LMS NXA86B Chinese

Rev. 0424 68 pages
Preview
BA

BA Tankvision LMS NXA86B Chinese

Rev. 0424 44 pages
Preview
BA

BA Tankvision LMS NXA86B Chinese

Rev. 0324 32 pages
Preview
BA

BA Tankvision LMS NXA86B Chinese

Rev. 0324 16 pages
Preview
BA

BA Tankvision Professional NXA85 Tankvision LMS NXA86B English

Rev. 2225 146 pages
Preview
BA

BA Tankvision Professional NXA85 Tankvision LMS NXA86B English

Rev. 2225 116 pages
Preview
BA

BA Tankvision NXA85, NXA86B Terminalvision NXS85 English

Rev. 2225 32 pages
Preview
BA

Tankvision Professional NXA85 / Tankvision LMS NXA86 English

Rev. 0720 50 pages
Preview
BA

BA Tankvision Professional NXA85 Tankvision LMS NXA86B Terminalvision NXS85 English

Rev. 0526 36 pages
Preview
BA

BA Tankvision LMS NXA86B English

Rev. 0526 44 pages
Preview
BA

BA Tankvision Professional NXA85 Tankvision LMS NXA86B English

Rev. 0525 24 pages
Preview
BA

Tankvision Professional NXA85 / Tankvision LMS NXA86 English

Rev. 0518 32 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · data manager — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was centralised data acquisition, storage and forwarding to management platforms.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means selected by channel count, storage depth and forwarding protocol.

What We Did

We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around selected by channel count, storage depth and forwarding protocol, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — automatic backfill after outages, greatly improving data completeness, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · data manager — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from data manager, focusing on centralised data acquisition, storage and forwarding to management platforms.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The data manager specification must therefore cover selected by channel count, storage depth and forwarding protocol.

Delivery Approach

Delivery was handled as the system components range — supplying as a full cabinet and signal-chain configuration. Execution centred on selected by channel count, storage depth and forwarding protocol, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — automatic backfill after outages, greatly improving data completeness, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · data manager — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is data manager; the focus is centralised data acquisition, storage and forwarding to management platforms.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with selected by channel count, storage depth and forwarding protocol.

Implementation

The scope ran through the system components range: supplying as a full cabinet and signal-chain configuration. Technically it hinges on selected by channel count, storage depth and forwarding protocol, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means automatic backfill after outages, greatly improving data completeness, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · data manager — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on data manager and the core task is centralised data acquisition, storage and forwarding to management platforms.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So data manager cannot be specified generically — it calls for selected by channel count, storage depth and forwarding protocol.

Solution

The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves selected by channel count, storage depth and forwarding protocol, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is automatic backfill after outages, greatly improving data completeness.