Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TM131-4C9F9/0

TM131-4C9F9/0
Product family: iTHERM ModuLine TM131
iTHERM ModuLine TM131
Endress+Hauser TM131-4C9F9/0
iTHERM ModuLine TM131;Approval Non-hazardous area;Thermowell Thermometer with thermowell, continuous, similar DIN43772 Form 2 G/F , 3 G/F;Thermometer Design Lagging, DIN43772 form 2G, 2F, 3G, 3F;Process/Thermowell Connection/Material G1/2 male thread; 316L/316Ti;Thermowell Diameter/Material 9x1.25mm; 316Ti;Tip Shape Straight (DIN 43772 form 2/2G/2F);Immersion Length U 100 mm;Removable Neck Length E 0mm, w/o neck;Lagging Length T 80 mm;Sensor Type/Measuring Range/Material 1x P

Order Code:TM131-4C9F9/0

Corresponding ext. order code:TM131-AABBCCC1BA4AGAC0AA1AA1+NQ

Name:iTHERM ModuLine TM131

Configuration

CodeNameOrderSpecification
010ApprovalAANon-hazardous area
020ThermowellBThermometer with thermowell, continuous, similar DIN43772 Form 2 G/F , 3 G/F
030Thermometer DesignBLagging, DIN43772 form 2G, 2F, 3G, 3F
050Process/Thermowell Connection; MaterialCCG1/2 male thread; 316L/316Ti
060Thermowell Diameter; MaterialC19x1.25mm; 316Ti
070Tip ShapeBStraight (DIN 43772 form 2/2G/2F)
080Immersion Length UA4100 mm
090Removable Neck Length EA0mm, w/o neck
100Lagging Length TG80 mm
110Sensor Type; Measuring Range; MaterialA1x Pt100 TF; -50...+400oC; 316L
130Sensor Standard; ClassificationCIEC60751; class A, 4-wire
140Electrical Connection0AFlying leads
150Terminal Head;Material;Protection ClassA1TA30A comfort flip cover; Alu; IP66/68
170Cable Entry Terminal HeadA1x M20x1.5 female thread
480Device ModelA11
610Accessory MountedNQ1x cable gland Polyamide
36 models · click to collapse