Product family: TU5300sc Turbidimeter + SC4500 Controller
TU5300sc Low Range Laser Turbidimeter, EPA Version, Automatic Cleaning Module, with SC4500 Controller, 1 Channel
HACH LXV525.97KTO011
The next standard in the evolution of turbidity

产品概述

The next standard in the evolution of turbidity

The EPA approved TU5 Series® platform employs a unique optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability between measurements. For the first time you will be able to remove uncertainty of which measurement to trust between your lab and process instruments, thanks to identical 360° x 90° Detection® Technology in any TU5 Series turbidimeter. The TU5300sc Low Range Laser Turbidimeter dramatically reduces the time needed to get a turbidity measurement you can rely on. A stable laser light source eliminates the need for annual lamp replacements. The turbidimeter’s measurement surface area has been reduced by 98%, allowing you to save time cleaning. An automatic cleaning module is available that keeps your instrument clean, reducing the amount of time spent cleaning the instrument ever further. All of this, along with the ability to measure to 2 mNTU, gives you the next standard in the evolution of turbidity. Only the new TU5 Series Lab & Process Turbidimeters with 360° x 90° Detection deliver unprecedented confidence that a change in your reading is a change in your water.

主要特点

  • Groundbreaking 360° x 90° Detection Technology:The TU5 Series employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability from test to test.
  • Everything about turbidity – faster:The TU5 Series dramatically reduces the time needed to get a turbidity measurement you can rely on, with 98% less online sample surface area to clean, sealed vials for calibration, and the elimination of the need for indexing and silicone oil in the lab. Not to mention, a smaller online sample volume means you will detect events almost immediately.
  • Easy Adoption:The familiar experience of a modern touchscreen, the ability to use your current Hach sensors, and the same footprint as the SC200, make installation and integration of the SC4500 Controller seamless.
  • No Time for Downtime:The SC4500's built-in predictive diagnostic software ensures measurement confidence and reduces the risk of unexpected equipment downtime by enabling proactive maintenance planning via MSM, including step-by-step instructions.

技术参数

参数名称说明
Accuracy±2% or 0.01 NTU from 0 - 40 NTU ±10% of reading from 40 - 1000 NTU based on Formazin primary standard
Cable Length1.6 m (5.25 ft), extendable up to 50 m (164 ft) for instrument without accessories
Calibration MethodFor Formazin and Stablcal®: 20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range Custom calibration for up to 6-point calibrations
CertificationsCE compliant US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version Australian ACMA Marking
Controller1 Channel, 100-240 VAC
Dimensions (H x W x D)249 mm x 268 mm x 190 mm
Enclosure RatingElectronic compartment IP55; all other functional units IP65 with process head/ACM attached to the TU5300sc/TU5400sc instrument
Fitting TypeSample quick connector: ¼-in. for ¼-in. tubing
InstrumentWith Automatic Cleaning Module
Light SourceClass 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
MaterialASA Luran S 777K / RAL7000, TPE RESIN Elastocon® STK40, Thermoplastic Elastomer TPS-SEBS
ModelTU5300sc
Mounting ConfigurationsWall Mount
Operating HumidityRelative humidity: 5 - 95% at different temperatures, non-condensing
Operating Temperature Range0 - 50 °C (32 - 122 °F)
OptionsProcess Head & Automatic Cleaning Module
RangeEPA: 0 - 700 NTU / FNU / TE/F / FTU 0 - 100 mg/L 0 - 175 EBC ISO: 0 - 1000 NTU / FNU / TE/F / FTU 0 - 100 mg/L 0 - 250 EBC
RegulatoryEPA
RepeatabilityBetter than 1% of reading or ±0.002 NTU (TU5300sc) or ±0.0006 NTU (TU5400sc) on Formazin at 25 °C (77 °F), whichever is greater
Resolution0.0001 NTU / FNU / TE/F / FTU / EBC
Response TimeTU5300sc: T90 <45 seconds at 100 mL/min TU5400sc: T90 <30 seconds at 100 mL/min
Sample Flow Rate100 - 1000 mL/min; optimal flow rate: 200 - 500 mL/min
Sample Pressure6 bar (87 psi) maximum, compared to air at sample temperature range from 2 - 40 °C (35.6 - 104 °F)
Sample Temperature2 - 60 °C (35 - 140 °F)
Signal Average TimeTU5300sc: 30 - 90 seconds TU5400sc: 1 - 90 seconds
Storage Conditions-40 - 60 °C (-40 - 140 °F)
Stray Light<10 mNTU
UnitsNTU, FNU, TE/F, FTU, EBC
VerificationLiquid: Stablcal®, Formazin (0.1 - 40 NTU) Dry: Glass Rod at <0.1 NTU
Weight5.95 lbs. (2.7 kg); 11 lbs. (5.0 kg) with all accessories
What's included?Controller, Non-Claros + Embedded Prognosys, without power cord; includes mounting hardware

应用领域

Filtration · Membrane Protection · Regulations · Water Reuse

同系列其他配置

型号
LXV525.97KTO005TU5300sc Low Range Laser Turbidimeter, EPA Version, with SC4500 Contro
LXV525.97KTO006TU5300sc Low Range Laser Turbidimeter, EPA Version, System Check, RFID
LXV525.97KTO007TU5300sc Low Range Laser Turbidimeter, EPA, Automatic Cleaning Module,
LXV525.97KTO008TU5300sc Low Range Laser Turbidimeter, ISO Version, with SC4500 Contr
LXV525.97KTO009TU5300sc Low Range Laser Turbidimeter, ISO Version, System Check, RFID
LXV525.97KTO010TU5300sc Low Range Laser Turbidimeter, ISO, Automatic Cleaning Module,
LXV525.97KTO012TU5300sc Low Range Laser Turbidimeter, EPA Version, Automatic Cleaning
LXV525.97KTO036TU5300sc Low Range Laser Turbidimeter, EPA Version, with SC4500 Contro
LXV525.97KTO037TU5300sc Low Range Laser Turbidimeter, EPA, Automatic Cleaning Module,
LXV525.97KTO040TU5300sc Low Range Laser Turbidimeter, EPA Version, System Check, RFID
LXV525.97KTO041TU5300sc Low Range Laser Turbidimeter, ISO Version, with SC4500 Contro
LXV525.97KTO042TU5300sc Low Range Laser Turbidimeter, ISO, Auto Cleaning, System Chec
LXV525.97KTO043TU5300sc Low Range Laser Turbidimeter, ISO Version, System Check, RFID
LXV525.97KTO045TU5300sc Low Range Laser Turbidimeter, EPA Version, with SC4500 Contro
LXV525.97KTO046TU5300sc Low Range Laser Turbidimeter, EPA, Auto Cleaning, System Chec
LXV525.97KTO047TU5300sc Low Range Laser Turbidimeter, ISO Version, System Check, RFID