产品概述
The next standard in the evolution of turbidity
The EPA approved TU5 Series® platform employs a unique optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability between measurements. For the first time you will be able to remove uncertainty of which measurement to trust between your lab and process instruments, thanks to identical 360° x 90° Detection® Technology in any TU5 Series turbidimeter. The TU5300sc Low Range Laser Turbidimeter dramatically reduces the time needed to get a turbidity measurement you can rely on. A stable laser light source eliminates the need for annual lamp replacements. The turbidimeter’s measurement surface area has been reduced by 98%, allowing you to save time cleaning. An automatic cleaning module is available that keeps your instrument clean, reducing the amount of time spent cleaning the instrument ever further. All of this, along with the ability to measure to 2 mNTU, gives you the next standard in the evolution of turbidity. Only the new TU5 Series Lab & Process Turbidimeters with 360° x 90° Detection deliver unprecedented confidence that a change in your reading is a change in your water.
主要特点
- Groundbreaking 360° x 90° Detection Technology:The TU5 Series employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability from test to test.
- Everything about turbidity – faster:The TU5 Series dramatically reduces the time needed to get a turbidity measurement you can rely on, with 98% less online sample surface area to clean, sealed vials for calibration, and the elimination of the need for indexing and silicone oil in the lab. Not to mention, a smaller online sample volume means you will detect events almost immediately.
- Easy Adoption:The familiar experience of a modern touchscreen, the ability to use your current Hach sensors, and the same footprint as the SC200, make installation and integration of the SC4500 Controller seamless.
- No Time for Downtime:The SC4500's built-in predictive diagnostic software ensures measurement confidence and reduces the risk of unexpected equipment downtime by enabling proactive maintenance planning via MSM, including step-by-step instructions.
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | ±2% or 0.01 NTU from 0 - 40 NTU ±10% of reading from 40 - 1000 NTU based on Formazin primary standard |
| Cable Length | 1.6 m (5.25 ft), extendable up to 50 m (164 ft) for instrument without accessories |
| Calibration Method | For Formazin and Stablcal®: 20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range Custom calibration for up to 6-point calibrations |
| Certifications | CE compliant US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version Australian ACMA Marking |
| Controller | 1 Channel, 100-240 VAC |
| Dimensions (H x W x D) | 249 mm x 268 mm x 190 mm |
| Enclosure Rating | Electronic compartment IP55; all other functional units IP65 with process head/ACM attached to the TU5300sc/TU5400sc instrument |
| Fitting Type | Sample quick connector: ¼-in. for ¼-in. tubing |
| Instrument | Standard Process Head |
| Light Source | Class 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50) |
| Material | ASA Luran S 777K / RAL7000, TPE RESIN Elastocon® STK40, Thermoplastic Elastomer TPS-SEBS |
| Model | TU5300sc |
| Mounting Configurations | Wall Mount |
| Operating Humidity | Relative humidity: 5 - 95% at different temperatures, non-condensing |
| Operating Temperature Range | 0 - 50 °C (32 - 122 °F) |
| Options | Process Head Only |
| Range | EPA: 0 - 700 NTU / FNU / TE/F / FTU 0 - 100 mg/L 0 - 175 EBC ISO: 0 - 1000 NTU / FNU / TE/F / FTU 0 - 100 mg/L 0 - 250 EBC |
| Regulatory | EPA |
| Repeatability | Better than 1% of reading or ±0.002 NTU (TU5300sc) or ±0.0006 NTU (TU5400sc) on Formazin at 25 °C (77 °F), whichever is greater |
| Resolution | 0.0001 NTU / FNU / TE/F / FTU / EBC |
| Response Time | TU5300sc: T90 <45 seconds at 100 mL/min TU5400sc: T90 <30 seconds at 100 mL/min |
| Sample Flow Rate | 100 - 1000 mL/min; optimal flow rate: 200 - 500 mL/min |
| Sample Pressure | 6 bar (87 psi) maximum, compared to air at sample temperature range from 2 - 40 °C (35.6 - 104 °F) |
| Sample Temperature | 2 - 60 °C (35 - 140 °F) |
| Signal Average Time | TU5300sc: 30 - 90 seconds TU5400sc: 1 - 90 seconds |
| Storage Conditions | -40 - 60 °C (-40 - 140 °F) |
| Stray Light | <10 mNTU |
| Units | NTU, FNU, TE/F, FTU, EBC |
| Verification | Liquid: Stablcal®, Formazin (0.1 - 40 NTU) Dry: Glass Rod at <0.1 NTU |
| Weight | 5.95 lbs. (2.7 kg); 11 lbs. (5.0 kg) with all accessories |
| What's included? | Controller, Non-Claros + Embedded Prognosys, without power cord; includes mounting hardware |
应用领域
Filtration · Membrane Protection · Regulations · Water Reuse
同系列其他配置
| 型号 | |
|---|---|
| LXV525.97KTO006 | TU5300sc Low Range Laser Turbidimeter, EPA Version, System Check, RFID |
| LXV525.97KTO007 | TU5300sc Low Range Laser Turbidimeter, EPA, Automatic Cleaning Module, |
| LXV525.97KTO008 | TU5300sc Low Range Laser Turbidimeter, ISO Version, with SC4500 Contr |
| LXV525.97KTO009 | TU5300sc Low Range Laser Turbidimeter, ISO Version, System Check, RFID |
| LXV525.97KTO010 | TU5300sc Low Range Laser Turbidimeter, ISO, Automatic Cleaning Module, |
| LXV525.97KTO011 | TU5300sc Low Range Laser Turbidimeter, EPA Version, Automatic Cleaning |
| LXV525.97KTO012 | TU5300sc Low Range Laser Turbidimeter, EPA Version, Automatic Cleaning |
| LXV525.97KTO036 | TU5300sc Low Range Laser Turbidimeter, EPA Version, with SC4500 Contro |
| LXV525.97KTO037 | TU5300sc Low Range Laser Turbidimeter, EPA, Automatic Cleaning Module, |
| LXV525.97KTO040 | TU5300sc Low Range Laser Turbidimeter, EPA Version, System Check, RFID |
| LXV525.97KTO041 | TU5300sc Low Range Laser Turbidimeter, ISO Version, with SC4500 Contro |
| LXV525.97KTO042 | TU5300sc Low Range Laser Turbidimeter, ISO, Auto Cleaning, System Chec |
| LXV525.97KTO043 | TU5300sc Low Range Laser Turbidimeter, ISO Version, System Check, RFID |
| LXV525.97KTO045 | TU5300sc Low Range Laser Turbidimeter, EPA Version, with SC4500 Contro |
| LXV525.97KTO046 | TU5300sc Low Range Laser Turbidimeter, EPA, Auto Cleaning, System Chec |
| LXV525.97KTO047 | TU5300sc Low Range Laser Turbidimeter, ISO Version, System Check, RFID |
资料下载
- Nova tecnologia de medição de turbidez em água – a Experiência para UE
- New Water Turbidity Measurement Technology - the US Experience
- Measuring Turbidity and Suspended Solids in Power Plants
- New TU5 Series Process Turbidimeter For Raw Water Monitoring
- Nouveaux turbidimètres de traitement série TU5 pour la surveillance de l’eau brute
- Lab Standards : Stay compliant with your turbidity reading using Stablcal Sealed Vials
- The NEW SC4500 Controller : SC4500 Controller vs SC200 Controller vs SC9500 Controller
- Introduction to Hach Services
Case Studies
Municipal Wastewater Treatment · Controllers and Sensors — Application Case
Site Conditions
This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was online water monitoring with a controller and sensor combination.
The Problem
The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means matching each controller channel to its sensor type.
What We Did
We took a Hach channel approach — supplying against the Hach original part numbers. Delivery was built around matching each controller channel to its sensor type, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.
Operating Outcome
In service the system performs as intended — factory-matched combinations that make faults easier to locate, with routine maintenance falling noticeably.
Food & Beverage · Controllers and Sensors — Application Case
Application Context
dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from Controllers and Sensors, focusing on online water monitoring with a controller and sensor combination.
Process Constraints
frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The Controllers and Sensors specification must therefore cover matching each controller channel to its sensor type.
Delivery Approach
Delivery was handled as the Hach channel — supplying against the Hach original part numbers. Execution centred on matching each controller channel to its sensor type, together with food-safety and hygienic design per 3-A / EHEDG.
Field Results
Operation shows the benefit clearly — factory-matched combinations that make faults easier to locate, with confidence in this measuring point improving markedly.
Chemical & Pharmaceutical · Controllers and Sensors — Application Case
Customer Profile
The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is Controllers and Sensors; the focus is online water monitoring with a controller and sensor combination.
Key Difficulties
Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with matching each controller channel to its sensor type.
Implementation
The scope ran through the Hach channel: supplying against the Hach original part numbers. Technically it hinges on matching each controller channel to its sensor type, and on these requirements: Ex certification and GMP traceability of records.
Customer Benefit
In practice this means factory-matched combinations that make faults easier to locate, which cut the workload on the site maintenance team.
Power & Energy · Controllers and Sensors — Application Case
Project Background
The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on Controllers and Sensors and the core task is online water monitoring with a controller and sensor combination.
Operating Challenges
The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So Controllers and Sensors cannot be specified generically — it calls for matching each controller channel to its sensor type.
Solution
The Ainstru engineering team worked through the Hach channel: supplying against the Hach original part numbers. The configuration involves matching each controller channel to its sensor type, with these requirements in view: compliance with power-industry codes and unit availability targets.
Results
Since start-up the system has run steadily; the practical result is factory-matched combinations that make faults easier to locate.
Related Products
HACHUniversal controller
HACHsc online nitrate analyzer
HACHpH/ORP/conductivity controller
HACHSludge blanket monitor (ultrasonic)
HACHPAH (polycyclic aromatic hydrocarbons) analyzer
HACH9582 dissolved oxygen meter
HACHsc oil-in-water analyzer
HACH