产品概述
The next standard in the evolution of turbidity
The ISO compliant TU5 Series® platform employs a unique optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability between measurements. For the first time you will be able to remove uncertainty of which measurement to trust between your lab and process instruments, thanks to identical 360° x 90° Detection® Technology in any TU5 Series turbidimeter The TU5300sc Low Range Laser Turbidimeter dramatically reduces the time needed to get a turbidity measurement you can rely on. A stable laser light source eliminates the need for annual lamp replacements. The turbidimeter’s measurement surface area has been reduced by 98%, allowing you to save time cleaning. An automatic cleaning module is available that keeps your instrument clean, reducing the amount of time spent cleaning the instrument ever further. All of this, along with the ability to measure to 2 mNTU, gives you the next standard in the evolution of turbidity. Only the new TU5 Series Lab & Process Turbidimeters with 360° x 90° Detection deliver unprecedented confidence that a change in your reading is a change in your water.
主要特点
- Groundbreaking 360° x 90° Detection Technology:The TU5 Series employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability from test to test.
- Matching lab and online results:For the first time you will be able to remove the uncertainty of which measurement to trust, thanks to identical 360° x 90° Detection Technology in both instruments.
- Everything about turbidity – faster:The TU5 Series dramatically reduces the time needed to get a turbidity measurement you can rely on, with 98% less online sample surface area to clean, sealed vials for calibration, and the elimination of the need for indexing and silicone oil in the lab. Not to mention, a smaller online sample volume means you will detect events almost immediately.
- No surprises:Prognosys™ monitors your TU5 Series online instrument, proactively alerting you to maintenance needs before your measurement becomes questionable. And a Hach Service Agreement protects your investment and helps ensure that you stay in compliance and on budget.
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | ±2% or 0.01 NTU from 0 - 40 NTU ±10% of reading from 40 - 1000 NTU based on Formazin primary standard |
| Cable Length | 1.6 m (5.25 ft), extendable up to 50 m (164 ft) for instrument without accessories |
| Calibration Method | For Formazin and Stablcal®: 20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range Custom calibration for up to 6-point calibrations |
| Certifications | CE compliant US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version Australian ACMA Marking |
| Controller | 2 Channels, 100-240 VAC |
| Dimensions (H x W x D) | 249 mm x 268 mm x 190 mm |
| Enclosure Rating | Electronic compartment IP55; all other functional units IP65 with process head/ACM attached to the TU5300sc/TU5400sc instrument |
| Fitting Type | Sample quick connector: ¼-in. for ¼-in. tubing |
| Instrument | Standard Process Head |
| Light Source | Class 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50) |
| Material | ASA Luran S 777K / RAL7000, TPE RESIN Elastocon® STK40, Thermoplastic Elastomer TPS-SEBS |
| Model | TU5300sc |
| Mounting Configurations | Wall Mount |
| Operating Humidity | Relative humidity: 5 - 95% at different temperatures, non-condensing |
| Operating Temperature Range | 0 - 50 °C (32 - 122 °F) |
| Options | Process Head Only |
| Range | EPA: 0 - 700 NTU / FNU / TE/F / FTU 0 - 100 mg/L 0 - 175 EBC ISO: 0 - 1000 NTU / FNU / TE/F / FTU 0 - 100 mg/L 0 - 250 EBC |
| Regulatory | ISO |
| Repeatability | Better than 1% of reading or ±0.002 NTU (TU5300sc) or ±0.0006 NTU (TU5400sc) on Formazin at 25 °C (77 °F), whichever is greater |
| Resolution | 0.0001 NTU / FNU / TE/F / FTU / EBC |
| Response Time | TU5300sc: T90 <45 seconds at 100 mL/min TU5400sc: T90 <30 seconds at 100 mL/min |
| Sample Flow Rate | 100 - 1000 mL/min; optimal flow rate: 200 - 500 mL/min |
| Sample Pressure | 6 bar (87 psi) maximum, compared to air at sample temperature range from 2 - 40 °C (35.6 - 104 °F) |
| Sample Temperature | 2 - 60 °C (35 - 140 °F) |
| Signal Average Time | TU5300sc: 30 - 90 seconds TU5400sc: 1 - 90 seconds |
| Storage Conditions | -40 - 60 °C (-40 - 140 °F) |
| Stray Light | <10 mNTU |
| Units | NTU, FNU, TE/F, FTU, EBC |
| Verification | Liquid: Stablcal®, Formazin (0.1 - 40 NTU) Dry: Glass Rod at <0.1 NTU |
| Weight | 5.95 lbs. (2.7 kg); 11 lbs. (5.0 kg) with all accessories |
| What's included? | Controller, Non-Claros + Embedded Prognosys, without power cord; includes mounting hardware |
应用领域
Filtration · Membrane Protection · Regulations · Water Reuse
同系列其他配置
| 型号 | |
|---|---|
| LXV525.97KTO005 | TU5300sc Low Range Laser Turbidimeter, EPA Version, with SC4500 Contro |
| LXV525.97KTO006 | TU5300sc Low Range Laser Turbidimeter, EPA Version, System Check, RFID |
| LXV525.97KTO007 | TU5300sc Low Range Laser Turbidimeter, EPA, Automatic Cleaning Module, |
| LXV525.97KTO008 | TU5300sc Low Range Laser Turbidimeter, ISO Version, with SC4500 Contr |
| LXV525.97KTO009 | TU5300sc Low Range Laser Turbidimeter, ISO Version, System Check, RFID |
| LXV525.97KTO010 | TU5300sc Low Range Laser Turbidimeter, ISO, Automatic Cleaning Module, |
| LXV525.97KTO011 | TU5300sc Low Range Laser Turbidimeter, EPA Version, Automatic Cleaning |
| LXV525.97KTO012 | TU5300sc Low Range Laser Turbidimeter, EPA Version, Automatic Cleaning |
| LXV525.97KTO036 | TU5300sc Low Range Laser Turbidimeter, EPA Version, with SC4500 Contro |
| LXV525.97KTO037 | TU5300sc Low Range Laser Turbidimeter, EPA, Automatic Cleaning Module, |
| LXV525.97KTO040 | TU5300sc Low Range Laser Turbidimeter, EPA Version, System Check, RFID |
| LXV525.97KTO042 | TU5300sc Low Range Laser Turbidimeter, ISO, Auto Cleaning, System Chec |
| LXV525.97KTO043 | TU5300sc Low Range Laser Turbidimeter, ISO Version, System Check, RFID |
| LXV525.97KTO045 | TU5300sc Low Range Laser Turbidimeter, EPA Version, with SC4500 Contro |
| LXV525.97KTO046 | TU5300sc Low Range Laser Turbidimeter, EPA, Auto Cleaning, System Chec |
| LXV525.97KTO047 | TU5300sc Low Range Laser Turbidimeter, ISO Version, System Check, RFID |
资料下载
- Nova tecnologia de medição de turbidez em água – a Experiência para UE
- New Water Turbidity Measurement Technology - the US Experience
- Measuring Turbidity and Suspended Solids in Power Plants
- New TU5 Series Process Turbidimeter For Raw Water Monitoring
- Nouveaux turbidimètres de traitement série TU5 pour la surveillance de l’eau brute
- Lab Standards : Stay compliant with your turbidity reading using Stablcal Sealed Vials
- The NEW SC4500 Controller : SC4500 Controller vs SC200 Controller vs SC9500 Controller
- Introduction to Hach Services
Related Products
HACHUniversal controller
HACHsc online nitrate analyzer
HACHpH/ORP/conductivity controller
HACHSludge blanket monitor (ultrasonic)
HACHPAH (polycyclic aromatic hydrocarbons) analyzer
HACH9582 dissolved oxygen meter
HACHsc oil-in-water analyzer
HACH