Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com
83F
Mass flowmeter
Configurable Models 1 models
Promass F has a long standing reputation as a highly accurate device under varying process conditions. It is suited for a broadest range of applications. Combined with the Promass 83 transmitter with touch control, four line display and extended functionality like software options for filling and dosing, concentration measurement or advanced diagnostics, Promass 83F offers premium accuracy in measurement of liquids and gases.
Compare

Density

Measuring Principle Coriolis
Characteristic / Application The universal and multivariable flowmeter for liquids and gases
Ambient temperature -20...65°C
(-4...+140°F)
Process temperature -50...+350°C
(-58...+662°F)
Process pressure PN 16...100
Cl 150...600
JIS 10...63K
Wetted parts 904L/1.4539
Alloy C-22/2.4602
Output 4...20mA
Pulse/Frequency (10KHz, active/passive)
Relays/Status
Certificates / Approvals ATEX
FM
CSA
TIIS

Density/Concentration

Measuring Principle Coriolis
Product headline The flowmeter with premium accuracy, robustness and extended transmitter functionality. Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor features Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi).
Transmitter features Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version.
Nominal diameter range DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3")
Wetted materials Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.1 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
Degree of protection IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs 4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay
Inputs 2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive)
Digital communication HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
Power supply DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals ATEX, IECEx, FM, CSA, NEPSI
Product safety CE, C-tick, EAC marking
Functional safety CE, C-tick
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Marine approvals and certificates Marine approval
Pressure approvals and certificates PED, CRN, AD 2000
Material certificates 3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Hygienic approvals and certificates 3-A, FDA

Gas

Measuring Principle Coriolis
Product headline The flowmeter with premium accuracy, robustness and extended transmitter functionality. Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor features Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi).
Transmitter features Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version.
Nominal diameter range DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3")
Wetted materials Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.1 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
Degree of protection IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs 4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay
Inputs 2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive)
Digital communication HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
Power supply DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals ATEX, IECEx, FM, CSA, NEPSI
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine
PED, CRN, AD 2000
3-A, FDA
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Marine approvals and certificates Marine approval
Pressure approvals and certificates PED, CRN, AD 2000
Material certificates 3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Hygienic approvals and certificates 3-A, FDA

Liquids

Measuring Principle Coriolis
Product headline The flowmeter with premium accuracy, robustness and extended transmitter functionality. Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor features Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi).
Transmitter features Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version.
Nominal diameter range DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3")
Wetted materials Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.1 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
Degree of protection IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs 4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay
Inputs 2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive)
Digital communication HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
Power supply DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals ATEX, IECEx, FM, CSA, NEPSI
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine
PED, CRN, AD 2000
3-A, FDA
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Product safety CE, C-tick, EAC marking
Functional safety CE, C-tick
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Marine approvals and certificates Marine approval
Pressure approvals and certificates PED, CRN, AD 2000
Material certificates 3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Hygienic approvals and certificates 3-A, FDA

Steam

Measuring Principle Coriolis
Product headline The flowmeter with premium accuracy, robustness and extended transmitter functionality. Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor features Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi).
Transmitter features Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version.
Nominal diameter range DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3")
Wetted materials Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.1 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
Degree of protection IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs 4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay
Inputs 2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive)
Digital communication HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
Power supply DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals ATEX, IECEx, FM, CSA, NEPSI
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine
PED, CRN, AD 2000
3-A, FDA
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Marine approvals and certificates Marine approval
Pressure approvals and certificates PED, CRN, AD 2000
Material certificates 3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK
Hygienic approvals and certificates 3-A, FDA

The Promass F series Coriolis flowmeter has a wide range of applications and has earned an excellent reputation for high-accuracy measurement under changing process conditions. In combination with the Promass 83 transmitter with touch control, four-line display and extended functions (such as filling, dosing, concentration measurement or advanced diagnostics), the Promass 83F mass flowmeter performs high-accuracy liquid and gas measurement.

 

Benefits

Modular design and operating concept for greater efficiency

Optional batching and concentration measurement software as extended functions

Diagnostics and data backup functions improve process quality

Integrated multivariable flow measurement

Balanced dual-tube measuring system design for excellent vibration resistance

Robust design, unaffected by external pipe forces

No inlet/outlet runs required, easy installation

 

Application

The Coriolis measuring principle is independent of the physical properties of the fluid, such as viscosity and density.

 

Extremely accurate measurement of liquid and gas flow, e.g. oils, lubricants, fuels, liquefied gases, solvents, foods and compressed gases (natural gas)

Fluid temperature up to +350 °C (662 °F)

Process pressure up to 100 bar (1450 psi)

Mass flow measurement up to 2200 t/h (80 850 lb/min)

Hazardous area approvals

 

ATEX, FM, CSA, TIIS

Spare Parts & Accessories 128

128 spare parts · click to collapse
Order codeDescription
50098557Power board220V = 85-260VACDetails
71039431Power boardHE = harsh environment 220V = 85-260VACDetails
50098558Explosion-proof power supply board220V = 85-260VACDetails
71039432Explosion-proof power supply boardHE = harsh environment 220V = 85-260VACDetails
71097758explosion-proof amplifier board220V = 85-260VACDetails
71097760*** Explosion-proof Power Supply Board220V = 85-260VAC HE = harsh environmentDetails
50098565Power board24V = 20-55VAC / 16-62VDCDetails
71039434Power boardHE = harsh environment 24V = 20-55VAC / 16-62VDCDetails
50098566Explosion-proof power supply boardKit P.s.b. 40/8X/65 20-55AC 16-62DC ExDetails
71039436Explosion-proof power supply boardHE = harsh environment 24V = 20-55VAC / 16-62VDCDetails
71097759Explosion-proof power supply board24V = 20-55VAC/16-62VDCDetails
71097761*** Explosion-proof Power Supply Board24V = 20-55VAC/16-62VDC HE = harsh environmentDetails
50094002fuseKit 10 fuses 250 VAC T800 MADetails
50094003fuseKit Bus/connec.b.5X/40/8X/65 field hous.Details
50106097*** Explosion-proof Amplifier BoardKit meas. amplifier PMASS 83 WEA EXDetails
71039409*** Explosion-proof Amplifier BoardLanguage: FR, ES, IT, NL, PT, DE, EN HE = harsh environmentDetails
50106098*** Explosion-proof Amplifier BoardKit meas. amplifier PMASS 83 EES EXDetails
71039410*** Explosion-proof Amplifier BoardLanguage: SV, FI, NO, RU, PL, CS, EN HE = harsh environmentDetails
50106099*** Explosion-proof Amplifier BoardKit meas. amplifier PMASS 83 SEA EXDetails
71039411*** Explosion-proof Amplifier BoardLanguage: JA, ID, EN HE = harsh environmentDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Measuring principle video

Click to play
1 models · click to collapse
All documents for this model
12 documents · click to expand
BA

Proline Promag 83 HART 操作手册 Chinese

HART Rev. 1412 152 pages
Preview
BA

Proline Promass 83 HART Operating Instructions English

HART Rev. 1514 148 pages
Preview
BA

Proline Promass 83 FOUNDATION Fieldbus Operating Instructions English

FOUNDATION-Fieldbus Rev. 1412 152 pages
Preview
BA

Proline Promass 83 Modbus RS485 Operating Instructions English

Modbus Rev. 1412 158 pages
Preview
BA

Proline Promass 83 PROFIBUS DP/PA Operating Instructions English

PROFIBUS-DP Rev. 1412 202 pages
Preview
BA

Proline Promass 83 HART Description of Device Functions English

HART Rev. 1314 206 pages
Preview
BA

Proline Promass 83 MODBUS RS485 Description of Device Functions English

Rev. 1108 192 pages
Preview
BA

Proline Promass 83 FOUNDATION Fieldbus Device Functions English

FOUNDATION-Fieldbus Rev. 1108 202 pages
Preview
BA

Proline Promass 83 PROFIBUS DP/PA Description of Device Functions English

PROFIBUS-DP Rev. 1108 182 pages
Preview
BA

Proline Promass 83 HART Description of Device Functions English

HART Rev. 0908 206 pages
Preview
BA

Proline Promass 83 MODBUS RS485 Operating Instructions English

Rev. 0610 154 pages
Preview
BA

Proline Promass 83 FOUNDATION Fieldbus Operating Instructions English

FOUNDATION-Fieldbus Rev. 0610 146 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Mass Flow Meter — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Mass Flow Meter, focusing on direct mass flow and density measurement.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Mass Flow Meter specification must therefore cover choosing tube geometry by flow range, entrained gas and hygienic needs.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing tube geometry by flow range, entrained gas and hygienic needs, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — no temperature or pressure compensation needed, making custody transfer more credible, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · Mass Flow Meter — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Mass Flow Meter; the focus is direct mass flow and density measurement.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing tube geometry by flow range, entrained gas and hygienic needs.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing tube geometry by flow range, entrained gas and hygienic needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means no temperature or pressure compensation needed, making custody transfer more credible, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Mass Flow Meter — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on Mass Flow Meter and the core task is direct mass flow and density measurement.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Mass Flow Meter cannot be specified generically — it calls for choosing tube geometry by flow range, entrained gas and hygienic needs.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing tube geometry by flow range, entrained gas and hygienic needs, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is no temperature or pressure compensation needed, making custody transfer more credible.

Power & Energy

Power & Energy · Mass Flow Meter — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Mass Flow Meter properly configured on the existing plant, with the aim of direct mass flow and density measurement.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Mass Flow Meter configuration has to involve choosing tube geometry by flow range, entrained gas and hygienic needs.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing tube geometry by flow range, entrained gas and hygienic needs, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is no temperature or pressure compensation needed, making custody transfer more credible, and the readings are now used for process tuning.