Technical Data
CompareDensity
| Measuring Principle | Coriolis |
| Characteristic / Application | The universal and multivariable flowmeterfor liquids and gases |
| Ambient temperature | -20...+65°C (-4...+140°F) |
| Process temperature | -50...+350°C (-58...+662°F) |
| Process pressure | PN 16...100 Cl 150...600 JIS 10...63K |
| Wetted parts | 904L/1.4539 Alloy C-22 |
| Output | 4...20mA Pulse/Frequency Status |
| Certificates / Approvals | ATEX FM CSA TIIS |
Density/Concentration
| Measuring Principle | Coriolis |
| Product headline | The robust flowmeter for demanding applications with a compact or remote transmitter. Highest measurement performance for liquids and gases under varying, demanding process conditions. |
| Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi). |
| Transmitter features | Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version. |
| Nominal diameter range | DN 8 to 250 (⅜ to 10") High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") |
| Wetted materials | Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density |
| Max. measurement error | Mass flow (liquid): ±0.15 % (standard), 0.1 % (option) Volume flow (liquid): ±0.15 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | Standard: –50 to +200 °C (–58 to +392 °F) High temperature: –50 to +350 °C (–58 to +662 °F) |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant |
| Transmitter housing material | Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast |
| Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
| Display/Operation | 2‐line backlit display with push buttons Configuration via local display and operating tools possible |
| Outputs | 3 outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) |
| Inputs | Status input |
| Digital communication | HART PROFIBUS PA |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Marine approvals and certificates | Marine approval |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Hygienic approvals and certificates | 3-A, EHEDG, FDA |
Gas
| Measuring Principle | Coriolis |
| Product headline | The robust flowmeter for demanding applications with a compact or remote transmitter. Highest measurement performance for liquids and gases under varying, demanding process conditions. |
| Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi). |
| Transmitter features | Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version. |
| Nominal diameter range | DN 8 to 250 (⅜ to 10") High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") |
| Wetted materials | Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density |
| Max. measurement error | Mass flow (liquid): ±0.15 % (standard), 0.1 % (option) Volume flow (liquid): ±0.15 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | Standard: –50 to +200 °C (–58 to +392 °F) High temperature: –50 to +350 °C (–58 to +662 °F) |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant |
| Transmitter housing material | Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast |
| Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
| Display/Operation | 2‐line backlit display with push buttons Configuration via local display and operating tools possible |
| Outputs | 3 outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) |
| Inputs | Status input |
| Digital communication | HART PROFIBUS PA |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI |
| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine PED, CRN, AD 2000 3-A,, FDA NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Marine approvals and certificates | Marine approval |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Hygienic approvals and certificates | 3-A, EHEDG, FDA |
Liquids
| Measuring Principle | Coriolis |
| Product headline | The robust flowmeter for demanding applications with a compact or remote transmitter. Highest measurement performance for liquids and gases under varying, demanding process conditions. |
| Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi). |
| Transmitter features | Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version. |
| Nominal diameter range | DN 8 to 250 (⅜ to 10") High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") |
| Wetted materials | Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density |
| Max. measurement error | Mass flow (liquid): ±0.15 % (standard), 0.1 % (option) Volume flow (liquid): ±0.15 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | Standard: –50 to +200 °C (–58 to +392 °F) High temperature: –50 to +350 °C (–58 to +662 °F) |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant |
| Transmitter housing material | Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast |
| Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
| Display/Operation | 2‐line backlit display with push buttons Configuration via local display and operating tools possible |
| Outputs | 3 outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) |
| Inputs | Status input |
| Digital communication | HART PROFIBUS PA |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI |
| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine PED, CRN, AD 2000 3-A, FDA NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Marine approvals and certificates | Marine approval |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Hygienic approvals and certificates | 3-A, EHEDG, FDA |
Steam
| Measuring Principle | Coriolis |
| Product headline | The robust flowmeter for demanding applications with a compact or remote transmitter. Highest measurement performance for liquids and gases under varying, demanding process conditions. |
| Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi). |
| Transmitter features | Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version. |
| Nominal diameter range | DN 8 to 250 (⅜ to 10") High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") |
| Wetted materials | Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density |
| Max. measurement error | Mass flow (liquid): ±0.15 % (standard), 0.1 % (option) Volume flow (liquid): ±0.15 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min) |
| Max. process pressure | PN 100, Class 600, 63K |
| Medium temperature range | Standard: –50 to +200 °C (–58 to +392 °F) High temperature: –50 to +350 °C (–58 to +662 °F) |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant |
| Transmitter housing material | Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast |
| Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
| Display/Operation | 2‐line backlit display with push buttons Configuration via local display and operating tools possible |
| Outputs | 3 outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) |
| Inputs | Status input |
| Digital communication | HART PROFIBUS PA |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI |
| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine PED, CRN, AD 2000 3-A, FDA NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Marine approvals and certificates | Marine approval |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |
| Hygienic approvals and certificates | 3-A, EHEDG, FDA |
The Promass F series has earned an excellent reputation for its high-precision measurement and equipment robustness, with a wide range of applications. With the Promass 80 transmitter, it provides precise flow measurement of liquids and gases under changing, demanding process conditions.
Benefits
-
Modular device and operating concept for greater efficiency
-
Data backup improves process quality
-
Compact multivariable flow measuring instrument
-
Balanced two-tube measuring system design with good vibration resistance
-
Rugged construction, unaffected by external pipe forces
-
No inlet/outlet straight pipe runs required, easy installation
Application areas
The Coriolis mass flow measuring principle is independent of the physical properties of the fluid, such as viscosity and density.
-
Extremely precise measurement of liquids and gases such as oils, lubricants, fuels, liquefied gases, solvents, food products and compressed gases (natural gas)
-
Fluid temperature up to +350 °C (+662 °F)
-
Process pressure up to 100 bar (1450 psi)
-
Mass flow measurement up to 2200 t/h (80 850 lb/min)
Hazardous area approval
-
ATEX, FM, CSA, TIIS
-
Spare Parts & Accessories 94
94 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 50098557 | Power board220V = 85-260VAC | Details |
| 71039431 | Power boardHE = harsh environment 220V = 85-260VAC | Details |
| 50098558 | Explosion-proof power supply board220V = 85-260VAC | Details |
| 71039432 | Explosion-proof power supply boardHE = harsh environment 220V = 85-260VAC | Details |
| 71097758 | explosion-proof amplifier board220V = 85-260VAC | Details |
| 71097760 | *** Explosion-proof Power Supply Board220V = 85-260VAC HE = harsh environment | Details |
| 50098565 | Power board24V = 20-55VAC / 16-62VDC | Details |
| 71039434 | Power boardHE = harsh environment 24V = 20-55VAC / 16-62VDC | Details |
| 50098566 | Explosion-proof power supply boardKit P.s.b. 40/8X/65 20-55AC 16-62DC Ex | Details |
| 71039436 | Explosion-proof power supply boardHE = harsh environment 24V = 20-55VAC / 16-62VDC | Details |
| 71097759 | Explosion-proof power supply board24V = 20-55VAC/16-62VDC | Details |
| 71097761 | *** Explosion-proof Power Supply Board24V = 20-55VAC/16-62VDC HE = harsh environment | Details |
| 50094002 | fuseKit 10 fuses 250 VAC T800 MA | Details |
| 50094003 | fuseKit Bus/connec.b.5X/40/8X/65 field hous. | Details |
| 50106094 | *** Explosion-proof Amplifier BoardLanguage: FR, ES, IT, NL, PT, DE, EN | Details |
| 71039405 | *** Explosion-proof Amplifier BoardLanguage: FR, ES, IT, NL, PT, DE, EN HE = harsh environment | Details |
| 50106095 | *** Explosion-proof Amplifier BoardKit meas. amplifier PMASS 80 EES EX | Details |
| 71039406 | *** Explosion-proof Amplifier BoardLanguage: SV, FI, NO, RU, PL, CS, EN HE = harsh environment | Details |
| 50106096 | *** Explosion-proof Amplifier BoardKit meas. amplifier PMASS 80 SEA EX | Details |
| 71039407 | *** Explosion-proof Amplifier BoardLanguage: JA, ID, EN HE = harsh environment | Details |
Configurator / Comparison
Measuring principle video
Click to playManuals & Documents 12
All documents for this model12 documents · click to expand
Proline Promass 80 HART Operating Instructions Chinese
Proline Promass 80 HART Operating Instructions English
Proline Promass 80 PROFIBUS PA Operating Instructions English
Proline Promass 80 English
Proline Promass 80 PROFIBUS PA Description of Device Functions English
Proline Promass 80 PROFIBUS PA Operating Instructions English
Proline Promass 80 HART Operating Instructions English
Promass 80 Device Functions English
80F English
Promass 80 PROFIBUS-PA Device Functions English
Proline Promass 80F, ,83F 科氏力质量流量测量系统 Chinese
科氏力质量流量测量系统 Chinese
Product Videos
Case Studies
Municipal Wastewater Treatment · Mass Flow Meter — Application Case
Application Context
the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Mass Flow Meter, focusing on direct mass flow and density measurement.
Process Constraints
effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Mass Flow Meter specification must therefore cover choosing tube geometry by flow range, entrained gas and hygienic needs.
Delivery Approach
Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing tube geometry by flow range, entrained gas and hygienic needs, together with stable compliance with Grade 1A discharge limits and online data reporting.
Field Results
Operation shows the benefit clearly — no temperature or pressure compensation needed, making custody transfer more credible, with confidence in this measuring point improving markedly.
Food & Beverage · Mass Flow Meter — Application Case
Customer Profile
The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Mass Flow Meter; the focus is direct mass flow and density measurement.
Key Difficulties
Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing tube geometry by flow range, entrained gas and hygienic needs.
Implementation
The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing tube geometry by flow range, entrained gas and hygienic needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.
Customer Benefit
In practice this means no temperature or pressure compensation needed, making custody transfer more credible, which cut the workload on the site maintenance team.
Chemical & Pharmaceutical · Mass Flow Meter — Application Case
Project Background
The project covers reactors, metering vessels and finished-product tanks. The work centres on Mass Flow Meter and the core task is direct mass flow and density measurement.
Operating Challenges
The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Mass Flow Meter cannot be specified generically — it calls for choosing tube geometry by flow range, entrained gas and hygienic needs.
Solution
The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing tube geometry by flow range, entrained gas and hygienic needs, with these requirements in view: Ex certification and GMP traceability of records.
Results
Since start-up the system has run steadily; the practical result is no temperature or pressure compensation needed, making custody transfer more credible.
Power & Energy · Mass Flow Meter — Application Case
Project Overview
The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Mass Flow Meter properly configured on the existing plant, with the aim of direct mass flow and density measurement.
Technical Challenges
What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Mass Flow Meter configuration has to involve choosing tube geometry by flow range, entrained gas and hygienic needs.
Configuration
Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing tube geometry by flow range, entrained gas and hygienic needs, checked line by line against: compliance with power-industry codes and unit availability targets.
Performance
After commissioning the outcome is no temperature or pressure compensation needed, making custody transfer more credible, and the readings are now used for process tuning.
Related Products
Endress+HauserMass flowmeter 8E3B
Endress+HauserCompact mass flowmeter
Endress+HauserMass flowmeter Promass K 10
Endress+HauserMass flowmeter
Endress+HauserMass flowmeter
Endress+HauserMass flowmeter
Endress+HauserFilling mass flowmeter
Endress+Hauser