Order Code:5W4C1H-AAELHP8DHD3K0A+CC
Name:Electromagnetic flowmeter
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | AA | Non-hazardous area |
| 011 | Design | E | Fixed flange |
| 015 | Power Supply | L | AC 100...240V, AC/DC 24V |
| 020 | Output; Input | H | 4-20mA HART, pulse/freq., switch output |
| 040 | Housing | P | Remote, alu, coated |
| 045 | Cable, Remote Version | 8 | 30m/90ft coil and signal cable |
| 050 | Electrical Connection | D | Thread NPT1/2 |
| 060 | Liner | H | Hard rubber |
| 070 | Process Connection | D3K | PN16, carbon steel, flange EN1092-1 |
| 075 | Electrodes | 0 | 1.4435/316L |
| 080 | Flow Calibration | A | 0.5% |
| 520 | Sensor Option | CC | IP68, Type 6P, customer potted, corrosion protection EN ISO 12944 C5-M/Im1 |
Configuration Explained
This is a 5W4C electromagnetic flowmeter with an EN ISO 12944 corrosion-protected sensor, for the water industry, it replaces the 50W, 53W and 5L4C, non-hazardous area, welded flange, 100-240V AC or 24V DC supply, 4-20mA HART plus pulse, frequency and switch, remote coated aluminium housing with a 30m signal cable so the head can be mounted near the control room, NPT1/2 entry, hard rubber liner, PN16 carbon steel flange, suitable for wastewater metering with remote display.