Order Code:5W4C50-AADLHA0AQD320A+AK
Name:Promag W 400, 5W4C50, DN50 2"
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | AA | Non-hazardous area |
| 011 | Design | D | Lap joint flange |
| 015 | Power Supply | L | AC 100...240V, AC/DC 24V |
| 020 | Output; Input | H | 4-20mA HART, pulse/freq., switch output |
| 040 | Housing | A | Compact, alu, coated |
| 045 | Cable, Remote Version | 0 | Not used |
| 050 | Electrical Connection | A | Gland M20 |
| 060 | Liner | Q | PTFE 90oC |
| 070 | Process Connection | D32 | PN16, carbon steel, lap joint flange EN1092-1 |
| 075 | Electrodes | 0 | 1.4435/316L |
| 080 | Flow Calibration | A | 0.5% |
| 500 | Operation Language Display | AK | Chinese simplified |
Configuration Explained
This is a 5W4C electromagnetic flowmeter for the water industry, it replaces the 50W, 53W and 5L4C, non-hazardous area, loose flange design so installation needs no pipe cutting, 100-240V AC or 24V DC supply, 4-20mA HART plus pulse, frequency and switch, compact coated aluminium housing, PTFE liner rated to 90 °C, PN16 carbon steel loose flange, 316L electrodes, 0.5% calibration, display in simplified Chinese, suitable for metering in wastewater and water supply networks.