Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

5W4C7H-GRKLHA0AHD2KHA+AIDA

5W4C7H-GRKLHA0AHD2KHA+AIDA
Product family: Electromagnetic flowmeter
Electromagnetic flowmeterIn Stock (2)
Endress+Hauser 5W4C7H-GRKLHA0AHD2KHA+AIDA
Promag W 400, 5W4C7H, DN700 28";Approval Non-hazardous area + EAC marking;Design Fixed flange, long face-to-face length, 0 x DN inlet/outlet runs;Power Supply AC 100...240V, AC/DC 24V;Output/Input 4-2

Order Code:5W4C7H-GRKLHA0AHD2KHA+AIDA

Name:Promag W 400, 5W4C7H, DN700 28"

Configuration

CodeNameOrderSpecification
010ApprovalGRNon-hazardous area + EAC marking
011DesignKFixed flange, long face-to-face length, 0 x DN inlet/outlet runs
015Power SupplyLAC 100...240V, AC/DC 24V
020Output; InputH4-20mA HART, pulse/freq., switch output
040HousingACompact, alu, coated
045Cable, Remote Version0Not used
050Electrical ConnectionAGland M20
060LinerHHard rubber
070Process ConnectionD2KPN10, carbon steel, flange EN1092-1
075ElectrodesHAlloy C22, bullet nose
080Flow CalibrationA0.5%
500Operation Language DisplayAIRussian
530Customized ParameterizationDAOutput 1

Configuration Explained

This is a 5W4C electromagnetic flowmeter for the water and wastewater industry, it replaces the 50W, 53W and 5L4C, with EAC marking, welded flange long face-to-face version with no straight pipe requirement upstream or downstream, a direct replacement in old pipelines, 100-240V AC or 24V DC supply, 4-20mA HART plus pulse, frequency and switch, hard rubber liner, PN10 carbon steel flange, Alloy C22 bullet-nose electrodes, wear and erosion resistant, suitable for inlet and outlet metering in wastewater plants.