Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

8A1B

8A1B
Mass flowmeter
Configurable Models 1 models
Promass A is known for its highly accurate measurement of small quantities of liquids and gases for high pressure and low pressure. Combined with the smallest transmitter housing available today it delivers full performance on the smallest footprint. Promass A 100 is the preferred choice for system integrators, skid builders and equipment manufacturers. Available with an ultra-compact stainless steel hygienic housing it can be placed even into the most compact rigs.
Compare

Density/Concentration

Measuring Principle Coriolis
Product headline The single-tube flowmeter for smallest flow quantities with an ultra-compact transmitter.
Measuring accurately smallest quantities of liquids and gases for continuous process control.
Sensor features Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +205 °C (+401 °F).
Transmitter features Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.
Nominal diameter range DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
Wetted materials Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 450 kg/h (0 to 16.5 lb/min)
Max. process pressure PN 40, Class 300, 20K, 400 bar (5800 psi)
Medium temperature range –50 to +205 °C (–58 to +401 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Compact: AlSi10Mg, coated
Compact/ultra-compact: 1.4301 (304)
Degree of protection Standard: IP66/67, type 4X enclosure
Option: IP69
Display/Operation 4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible
Outputs 4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs None
Digital communication HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
Power supply DC 20 to 30 V
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC
Product safety CE, C-Tick, EAC marking
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, EHEDG, cGMP

Gas

Measuring Principle Coriolis
Product headline The single-tube flowmeter for smallest flow quantities with an ultra-compact transmitter.
Measuring accurately smallest quantities of liquids and gases for continuous process control.
Sensor features Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +205 °C (+401 °F).
Transmitter features Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.
Nominal diameter range DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
Wetted materials Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 450 kg/h (0 to 16.5 lb/min)
Max. process pressure PN 40, Class 300, 20K, 400 bar (5800 psi)
Medium temperature range –50 to +205 °C (–58 to +401 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Compact: AlSi10Mg, coated
Compact/ultra‐compact: 1.4301 (304)
Degree of protection Standard: IP66/67, type 4X enclosure
Option: IP69
Display/Operation 4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible
Outputs 4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs None
Digital communication HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
Power supply DC 20 to 30 V
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC
Other approvals and certificates
Product safety CE, C-Tick, EAC marking
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, EHEDG, cGMP

Liquids

Measuring Principle Coriolis
Product headline The single-tube flowmeter for smallest flow quantities with an ultra-compact transmitter.
Measuring accurately smallest quantities of liquids and gases for continuous process control.
Sensor features Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +205 °C (+401 °F).
Transmitter features Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available.
Nominal diameter range DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
Wetted materials Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 450 kg/h (0 to 16.5 lb/min)
Max. process pressure PN 40, Class 300, 20K, 400 bar (5800 psi)
Medium temperature range –50 to +205 °C (–58 to +401 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Compact: AlSi10Mg, coated
Compact/ultra-compact: 1.4301 (304)
Degree of protection Standard: IP66/67, type 4X enclosure
Option: IP69
Display/Operation 4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible
Outputs 4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs None
Digital communication HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
Power supply DC 20 to 30 V
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC
Product safety CE, C-Tick, EAC marking
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, EHEDG, cGMP

The Promass A mass flowmeter can be used for precise measurement of small liquid and gas flows at high and low pressure. Combined with the smallest available transmitter, the Promass A 100 flowmeter is perfect for minimum flow measurement and is the first choice of system integrators, skid manufacturers and other equipment manufacturers. The Promass A100 has an ultra-compact stainless steel hygienic housing and can be installed in confined spaces.

 

Advantages

Maximum process safety - self-draining measuring tube design

Fewer process measuring points - multivariable measurement (flow, density, temperature)

Space-saving installation - no inlet/outlet straight runs required

Compact transmitter for measuring minimum flows

Time-saving on-site operation without additional software and hardware - integrated web server

Comprehensive verification - Heartbeat technology

 

Application areas

Coriolis measuring principle unaffected by the physical properties of the fluid itself (e.g. viscosity and density).

Precise measurement of very small flows of liquids and gases in continuous processes.

Device features

 

Nominal diameter: DN 1 to 4 (1/24 to 1/8")

Process pressure up to 400 bar (5800 psi)

Medium temperature up to +205 °C (+401 °F)

Robust ultra-compact transmitter housing

High degree of protection: IP69K

With field display

Spare Parts & Accessories 26

26 spare parts · click to collapse
Order codeDescription
XPD0005-Electronic plug-in module 100 qualityMain electronic moduleEnquire
XPD0023-Display moduleUsage: Promag 100, Promass 100, Prosonic Flow E 100.Enquire
71185785Intrinsically Safe BarrierUsage: Promass 100, CNGmass, LPGmass, LNGmass.Details
71185787Safety barrier connection assemblyUsage: Promass 100, CNGmass, LPGmass, LNGmass. Consists of: 2x Connection terminal 4-Pol.Details
71185788T-DAT moduleDetails
71185789Aluminum meter coverUsage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Consists of: Cover Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover.Details
71185790Stainless Steel CoverUsage: Promass 100, Promag 100, Prosonic Flow 100. Consists of: Cover stainless 1.4301. Gasket EPDM for cover.Details
71185793Stainless Steel CoverUsage: Promag/Promass 100, Promag/Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4301, gasket EPDM for cover.Details
71266334Aluminum Cover Assembly, Glass Window, IntegratedUsage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat. Consists of: Cover with sight glass Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover.Details
71266335Aluminum Cover Assembly, Glass Window, IntegratedUsage: Promass 100, Promag 100, Prosonic Flow 100. Consists of: Cover with sight glass stainless 1.4301. Gasket EPDM for cover.Details
71266337Aluminum cover assembly, glass window, ultra-compactUsage: Promass 100, Promag 100. Consists of: Cover with sight glass stainless 1.4301. Gasket EPDM for cover.Details
71185795aluminum housing seal ringUsage: Promass 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Consists of: O-Ring 113,90 x 3,53 NBR for cover. Gasket HNBR for housing/sensor.Details
71185797Stainless steel housing seal ringUsage: Promass 100, Prosonic Flow 100. Consists of: Gasket EPDM for cover. Gasket HNBR for housing/sensor.Details
71185799Housing seal ringUsage: Promass 100, Promass 500 digital, sensor connection housing. Consists of: gasket EPDM for cover, gasket HNBR for housing/sensor.Details
50098036Explosion-proof cable glandKit 10 cable glands M20x1.5 ExDetails
71069285cable gland assemblyDetails
50098041adapterKit 10 extension M20x1.5/G 1/2"Details
71185802cable gland assemblyConsists of: 2 x Extension M20x1,5/G1/2" 1.4404. 2 x O-Ring. 2 x Sealing plug G1/2".Details
50098042adapterKit 10 extension M20x1.5/NPT 1/2"Details
71185800cable gland assemblyConsists of: 2 x Extension M20x1,5/NPT1/2" 1.4404. 2 x O-Ring. 2 x Sealing plug NPT1/2".Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories / Spare parts

 

Measuring principle video

Click to play
1 models · click to collapse
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Mass Flow Meter — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Mass Flow Meter, focusing on direct mass flow and density measurement.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Mass Flow Meter specification must therefore cover choosing tube geometry by flow range, entrained gas and hygienic needs.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing tube geometry by flow range, entrained gas and hygienic needs, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — no temperature or pressure compensation needed, making custody transfer more credible, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · Mass Flow Meter — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Mass Flow Meter; the focus is direct mass flow and density measurement.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing tube geometry by flow range, entrained gas and hygienic needs.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing tube geometry by flow range, entrained gas and hygienic needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means no temperature or pressure compensation needed, making custody transfer more credible, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Mass Flow Meter — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on Mass Flow Meter and the core task is direct mass flow and density measurement.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Mass Flow Meter cannot be specified generically — it calls for choosing tube geometry by flow range, entrained gas and hygienic needs.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing tube geometry by flow range, entrained gas and hygienic needs, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is no temperature or pressure compensation needed, making custody transfer more credible.

Power & Energy

Power & Energy · Mass Flow Meter — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Mass Flow Meter properly configured on the existing plant, with the aim of direct mass flow and density measurement.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Mass Flow Meter configuration has to involve choosing tube geometry by flow range, entrained gas and hygienic needs.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing tube geometry by flow range, entrained gas and hygienic needs, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is no temperature or pressure compensation needed, making custody transfer more credible, and the readings are now used for process tuning.