Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

8A2B 200 Coriolis flowmeter

8A2B 200 Coriolis flowmeter
200 Coriolis flowmeter
The compact Promass A is ideal for continuous process control in demanding applications. Its unique self-drainable single-tube system enables accurate measurement of liquids and gases at lowest flow rates and high pressure. With its cost-effective genuine loop-powered technology and intrinsically safe design (Ex ia), Promass A 200 offers highest operational safety in hazardous areas. Heartbeat Technology ensures safe processes.
Compare

Density/Concentration

Measuring Principle Coriolis
Product headline Genuine loop-powered flowmeter for accurate measurement of lowest flow rates.
Suitable for applications with smallest flow quantities in the chemical industry.
Sensor features Space-saving installation – compact, lightweight sensor. Highest product quality – self-drainable measuring tube design in all line sizes. Optimum process safety – resistant to corrosive ambient conditions and internal clogging.
Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 430.9 bar (6250 psi). Medium temperature up to +205 °C (+401 °F).
Transmitter features Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
Nominal diameter range DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
Wetted materials Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 450 kg/h (0 to 16.54 lb/min)
Max. process pressure 430.9 bar (6250 psi)
Medium temperature range -50 to 205 °C (-58 to 401 °F)
Ambient temperature range -40 to 60 °C (-40 to +140 °F)
Sensor housing material Stainless steel, 1.4404 (316L)
Transmitter housing material Stainless steel, CF-3M (316L, 1.4404)
AlSi10MG, coated
Degree of protection IP66/67, Type 4X enclosure
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs 4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
Inputs None
Digital communication HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply DC 18 to 35 V (4‐20 mA HART with/without
pulse/frequency/switch)
DC 18 to 30 V (20 mA HART, 4‐20 mA)
DC 9 to 32 V (PROFIBUS PA)
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI, UK Ex, KC
Product safety CE, C-TICK
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, cGMP

Gas

Measuring Principle Coriolis
Product headline Genuine loop-powered flowmeter for accurate measurement of lowest flow rates.
Suitable for applications with smallest flow quantities in the chemical industry.
Sensor features Space-saving installation – compact, lightweight sensor. Highest product quality – self-drainable measuring tube design in all line sizes. Optimum process safety – resistant to corrosive ambient conditions and internal clogging.
Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 430.9 bar (6250 psi). Medium temperature up to +205 °C (+401 °F).
Transmitter features Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
Nominal diameter range DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
Wetted materials Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 450 kg/h (0 to 16.54 lb/min)
Max. process pressure 430.9 bar (6250 psi)
Medium temperature range -50 to 205 °C (-58 to 401 °F)
Ambient temperature range -40 to 60 °C (-40 to +140 °F)
Sensor housing material Stainless steel, 1.4404 (316L)
Transmitter housing material Stainless steel, CF-3M (316L, 1.4404)
AlSi10MG, coated
Degree of protection IP66/67, Type 4X enclosure
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs 4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
Inputs None
Digital communication HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply DC 18 to 35 V (4‐20 mA HART with/without
pulse/frequency/switch)
DC 18 to 30 V (20 mA HART, 4‐20 mA)
DC 9 to 32 V (PROFIBUS PA)
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI, UK Ex, KC
Product safety CE, C-TICK
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, cGMP

Liquids

Measuring Principle Coriolis
Product headline Genuine loop-powered flowmeter for accurate measurement of lowest flow rates.
Suitable for applications with smallest flow quantities in the chemical industry.
Sensor features Space-saving installation – compact, lightweight sensor. Highest product quality – self-drainable measuring tube design in all line sizes. Optimum process safety – resistant to corrosive ambient conditions and internal clogging.
Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 430.9 bar (6250 psi). Medium temperature up to +205 °C (+401 °F).
Transmitter features Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
Nominal diameter range DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
Wetted materials Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 450 kg/h (0 to 16.54 lb/min)
Max. process pressure 430.9 bar (6250 psi)
Medium temperature range -50 to 205 °C (-58 to 401 °F)
Ambient temperature range -40 to 60 °C (-40 to +140 °F)
Sensor housing material Stainless steel, 1.4404 (316L)
Transmitter housing material Stainless steel, CF-3M (316L, 1.4404)
AlSi10MG, coated
Degree of protection IP66/67, Type 4X enclosure
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs 4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
Inputs None
Digital communication HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply DC 18 to 35 V (4‐20 mA HART with/without
pulse/frequency/switch)
DC 18 to 30 V (20 mA HART, 4‐20 mA)
DC 9 to 32 V (PROFIBUS PA)
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI, UK Ex, KC
Product safety CE, C-TICK
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, cGMP

Proline Promass A 200
Coriolis flowmeter
True loop-powered flowmeter for precise measurement of the lowest flow rates
Advantages
Space-saving installation – compact, lightweight sensor

Highest product quality – self-draining measuring tube design for all pipe sizes

Optimum process safety – resistant to corrosive environmental conditions and internal clogging

Convenient device wiring – separate connection compartment

Safe operation – no need to open the device thanks to the display with touch control and background lighting

Integrated verification – Heartbeat Technology
Field of application
The compact Promass A is ideal for continuous process control in demanding applications. Its unique self-draining single-tube system enables accurate measurement of liquids and gases at the lowest flow rates and high pressures. The Promass A 200 uses cost-effective, genuine loop-powered technology and intrinsically safe design (Ex ia), providing the highest operational safety in explosion-protected areas. Heartbeat Technology enables safe processes.

The measuring principle is unaffected by fluid properties such as viscosity or density

Suitable for applications with the lowest flow rates in the chemical industry.

Device properties

Nominal diameter: DN 1 to 4 (1/24 to 1/8”)

Process pressure up to 430.9 bar (6250 psi)

Medium temperature up to +205 °C (+401 °F)

Loop-powered technology

Robust two-compartment housing

Plant safety: global certifications (SIL, hazardous area)

Spare Parts & Accessories 45

45 spare parts · click to collapse
Order codeDescription
XPD0001-Mass flowmeter electronic insert 200Main electronic moduleEnquire
71108602I/O moduleNon-Ex, Ex. Current output, 4-20mA HART + 4-20mA analog. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.Details
XPD0015-I/O module, 2-wire, 4-20mA, HART, ExNon-Ex, Ex. 1x current output HART.Enquire
XPD0016-I/O module, 2-wire, 4-20mA, HART, PFS, ExNon-Ex, Ex. 1x current output HART. 1x PFS= pulse/freq./switch output.Enquire
71164940I/O moduleNon-Ex, Ex. PROFIBUS PA, FOUNDATION Fieldbus. PFS=switch output. Version 2. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass 200, Prowirl 200, Promag 200.Details
71128617Overvoltage protector4-20mA HART. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.Details
71128619Overvoltage protector4-20mA HART, PROFIBUS PA, FOUNDATION Fieldbus, Imp./Freq./Switch output. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/ FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.Details
XPD0024-Display moduleFor housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, t-mass 150, Promag 200, Prowirl 200. Consists of: Display SD02, helix cable, ribbon cable, connector cover.Enquire
XPD0025-Display moduleFor housing: GT18, GT19, GT20. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57, FMR60/62/67, FHX50. Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. Consists of: Display SD03 illuminated, ribbon cable, connector cover.Enquire
71197334Transmitter FHX50Consists of: electronics, ribbon cable. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. Usage: Promass200, Prowirl 200, Promag 200, Prosonic Flow 200.Details
71296840Plug connector M12, VATo connect FHX50. Usage: FMP50/51/52/53/54/55/56/57, FMR50/51/52/53/54/56/57. Not for dust Ex. Usage: Prowirl 200, Promass 200, Promag 200, Prosonic Flow 200.Details
71206552CableConnection cable, shielded. Usage: FHX50, FHX50B.Details
71206554CableConnection cable, shielded. Usage: FHX50, FHX50B.Details
71206555CableConnection cable, shielded. Usage: FHX50, FHX50B.Details
71206556CableConnection cable, shielded. Usage: FHX50, FHX50B.Details
71110280Terminal kit 2-wire, I/O moduleConsists of: 4x terminal 2-pole, green. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.Details
71110281Aluminum coverMaterial: 316L. O-ring, EPDM, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.Details
71110282Aluminum coverMaterial: 316L. O-ring NBR, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67, FHX50. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.Details
71110291Aluminum coverMaterial: 316L. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP51/FMP52/FMP54/FMP55/FMP56/FMP57, FMR51/FMR52/FMR53/FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.Details
71110284Aluminum coverMaterial: 316L. O-ring EPDM /PTFE coated. Usage: terminal compartment Ex d/XP, FMP51/FMP52/FMP54/FMP55/FMP56/FMP57, FMR51/FMR52/FMR53/FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Mass Flow Meter — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Mass Flow Meter, focusing on direct mass flow and density measurement.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Mass Flow Meter specification must therefore cover choosing tube geometry by flow range, entrained gas and hygienic needs.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing tube geometry by flow range, entrained gas and hygienic needs, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — no temperature or pressure compensation needed, making custody transfer more credible, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · Mass Flow Meter — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Mass Flow Meter; the focus is direct mass flow and density measurement.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing tube geometry by flow range, entrained gas and hygienic needs.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing tube geometry by flow range, entrained gas and hygienic needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means no temperature or pressure compensation needed, making custody transfer more credible, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Mass Flow Meter — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on Mass Flow Meter and the core task is direct mass flow and density measurement.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Mass Flow Meter cannot be specified generically — it calls for choosing tube geometry by flow range, entrained gas and hygienic needs.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing tube geometry by flow range, entrained gas and hygienic needs, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is no temperature or pressure compensation needed, making custody transfer more credible.

Power & Energy

Power & Energy · Mass Flow Meter — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Mass Flow Meter properly configured on the existing plant, with the aim of direct mass flow and density measurement.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Mass Flow Meter configuration has to involve choosing tube geometry by flow range, entrained gas and hygienic needs.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing tube geometry by flow range, entrained gas and hygienic needs, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is no temperature or pressure compensation needed, making custody transfer more credible, and the readings are now used for process tuning.