Technical Data
CompareDensity
| Measuring Principle | |
| Product Headline | std_productprofile_product_usp_7824. Measuring accurately smallest quantities of liquids and gases for continuous process control. |
| Sensor features | Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +205 °C (+401 °F). |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. |
Density/Concentration
| Measuring Principle | |
| Product headline | std_productprofile_product_usp_7824. Measuring accurately smallest quantities of liquids and gases for continuous process control. |
| Sensor features | Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +205 °C (+401 °F). |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. |
| Nominal diameter range | DN 1 to 4 (¹⁄₂₄ to ¹⁄₈") |
| Wetted materials | Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 450 kg/h (0 to 16.5 lb/min) |
| Max. process pressure | PN 40, Class 300, 20K, 400 bar (5800 psi) |
| Medium temperature range | –50 to +205 °C (–58 to +401 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant |
| Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design |
| Degree of protection | IP66/67, type 4X enclosure IP69 |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available |
| Outputs | 3 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV SÜD attestation) |
| Pressure approvals and certificates | CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A, EHEDG |
Gas
| Measuring Principle | |
| Product headline | std_productprofile_product_usp_7824. Measuring accurately smallest quantities of liquids and gases for continuous process control. |
| Sensor features | Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +205 °C (+401 °F). |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. |
| Nominal diameter range | DN 1 to 4 (¹⁄₂₄ to ¹⁄₈") |
| Wetted materials | Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.10 % Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 450 kg/h (0 to 16.5 lb/min) |
| Max. process pressure | PN 40, Class 300, 20K, 400 bar (5800 psi) |
| Medium temperature range | –50 to +205 °C (–58 to +401 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant |
| Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design |
| Degree of protection | IP66/67, type 4X enclosure IP69 |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available" |
| Outputs | 3 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV SÜD attestation)" |
| Pressure approvals and certificates | CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A, EHEDG |
Liquids
| Measuring Principle | |
| Product headline | std_productprofile_product_usp_7824. Measuring accurately smallest quantities of liquids and gases for continuous process control. |
| Sensor features | Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +205 °C (+401 °F). |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. |
| Nominal diameter range | DN 1 to 4 (¹⁄₂₄ to ¹⁄₈") |
| Wetted materials | Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.10 % Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 450 kg/h (0 to 16.5 lb/min) |
| Max. process pressure | PN 40, Class 300, 20K, 400 bar (5800 psi) |
| Medium temperature range | –50 to +205 °C (–58 to +401 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant |
| Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design |
| Degree of protection | IP66/67, type 4X enclosure IP69 |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available |
| Outputs | 3 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV SÜD attestation) |
| Pressure approvals and certificates | CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A, EHEDG |
Advantages
• Maximum process safety: self-draining measuring tube
• Fewer process measuring points: multivariable measurement (flow, density, temperature)
• Small installation space required: no inlet/outlet straight run requirements
• Complete process and diagnostic information: various user-configurable input/output
combinations and fieldbuses
• Reduced complexity and variability: user-configurable input/output settings
• Integrated verification: Heartbeat Technology
Applications
• Measuring principle unaffected by the physical properties of the fluid (e.g. viscosity or density)
• High-precision measurement of very small liquid and gas flows
in continuous process control
Device performance
• Nominal diameter: DN 1...4 (¹⁄₂₄...¹⁄₈")
• Maximum process pressure: 400 bar (5 800 psi)
• Maximum medium temperature: +205 °C (+401 °F)
• Compact dual-compartment housing with up to 3 inputs/outputs
• Backlit display, touch control, WLAN access
• Remote display unit available
Spare Parts & Accessories 59
59 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| XPD0028- | 300/500 ISEM electronic plug-in moduleUsage: Promass, Cubemass 300/500, HPFmass 500 | Enquire |
| XPD0037- | I/O moduleUsage: Proline 300/500 | Enquire |
| XPD0038- | I/O moduleUsage: Proline 300/500 | Enquire |
| XPD0031- | Display moduleUsage: Proline 300/500, DKX001. | Enquire |
| 71323007 | Power supply assemblyUsage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing, electronic compartment. | Details |
| 71323008 | Power supply assemblyUsage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing, electronic compartment. | Details |
| 71323009 | Power supply assemblyUsage: Promag/Promass/Prosonic Flow/ t-mass/Teqwave MW 300/500 digital, Non-haz, Zone 2, transmitter housing, electronic compartment. | Details |
| 71185788 | T-DAT module | Details |
| 71323010 | Module housing, 300/500, ExUsage: transmitter housing, electronic compartment. Consists of: module cartridge incl. interconnection board. | Details |
| 71323011 | Module box, 300, Non-hazUsage: transmitter housing, electronic compartment. Consists of: module cartridge incl. interconnection board. | Details |
| 71323005 | ribbon cable assemblyUsage: Promag/Promass 300/500, t-mass/Teqwave MW 300, transmitter housing. | Details |
| 71323073 | Terminal Block AssemblyUsage: transmitter housing Alu/hygienic, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol. | Details |
| 71323074 | Terminal Block AssemblyUsage: transmitter housing Alu/hygienic, connection compartment. Option B = EtherNet, PROFINET. Consists of: 1x connection terminal 3-Pol., 1x connection terminal 4-Pol. | Details |
| 71327818 | Terminal Block AssemblyUsage: transmitter housing Alu/hygienic, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol. | Details |
| 71323075 | Terminal Block AssemblyUsage: transmitter housing Alu/cast, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus, Profinet APL, Modbus TCP APL. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol. | Details |
| 71323076 | Terminal Block AssemblyUsage: transmitter housing Alu/cast, connection compartment. Option B = EtherNet, PROFINET. Consists of: 2x connection terminal 2-Pol. | Details |
| 71327819 | Terminal Block AssemblyUsage: transmitter housing Alu/cast, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol. | Details |
| 71323079 | Terminal Block AssemblyUsage: transmitter housing Alu/cast, connection compartment with remote display DKX001. Consists of: 1x connection terminal 4-Pol. | Details |
| 71323016 | Cover AssemblyUsage: Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 300, Prosonic Flow 500, transmitter housing Alu, Non-haz. Promag/Promass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu, Ex. Consists of: cover sight glass, Alu, O-Ring 110.7x3.53 HNBR. | Details |
| 71323017 | Cover AssemblyUsage: Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Promass 300, Promag/Promass/Prosonic Flow 500, transmitter housing Alu, Ex. Consists of: cover sight glass, Alu, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF. | Details |
Configurator / Comparison
Accessories / Spare parts
Measuring principle video
Click to play12 documents · click to expand
Proline Promass A 300 FOUNDATION Fieldbus 操作手册 Chinese
Proline Promass A 300 HART 操作手册 Chinese
Proline Promass A 300 Modbus RS485 操作手册 Chinese
Proline Promass A 300 PROFIBUS PA 操作手册 Chinese
Proline Promass A 300 HART Operating Instructions English
Proline Promass A 300 Modbus RS485 Operating Instructions English
Proline Promass A 300 PROFINET Operating Instructions English
Proline Promass A 300 EtherNet/IP Operating Instructions English
Proline Promass A 300 FOUNDATION Fieldbus Operating Instructions English
Proline Promass A 300 PROFIBUS PA Operating Instructions English
Proline Promass A 300 技术资料 Chinese
Proline Promass A 300 Technical Information English
Case Studies
Municipal Wastewater Treatment · Mass Flow Meter — Application Case
Application Context
the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Mass Flow Meter, focusing on direct mass flow and density measurement.
Process Constraints
effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Mass Flow Meter specification must therefore cover choosing tube geometry by flow range, entrained gas and hygienic needs.
Delivery Approach
Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing tube geometry by flow range, entrained gas and hygienic needs, together with stable compliance with Grade 1A discharge limits and online data reporting.
Field Results
Operation shows the benefit clearly — no temperature or pressure compensation needed, making custody transfer more credible, with confidence in this measuring point improving markedly.
Food & Beverage · Mass Flow Meter — Application Case
Customer Profile
The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Mass Flow Meter; the focus is direct mass flow and density measurement.
Key Difficulties
Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing tube geometry by flow range, entrained gas and hygienic needs.
Implementation
The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing tube geometry by flow range, entrained gas and hygienic needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.
Customer Benefit
In practice this means no temperature or pressure compensation needed, making custody transfer more credible, which cut the workload on the site maintenance team.
Chemical & Pharmaceutical · Mass Flow Meter — Application Case
Project Background
The project covers reactors, metering vessels and finished-product tanks. The work centres on Mass Flow Meter and the core task is direct mass flow and density measurement.
Operating Challenges
The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Mass Flow Meter cannot be specified generically — it calls for choosing tube geometry by flow range, entrained gas and hygienic needs.
Solution
The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing tube geometry by flow range, entrained gas and hygienic needs, with these requirements in view: Ex certification and GMP traceability of records.
Results
Since start-up the system has run steadily; the practical result is no temperature or pressure compensation needed, making custody transfer more credible.
Power & Energy · Mass Flow Meter — Application Case
Project Overview
The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Mass Flow Meter properly configured on the existing plant, with the aim of direct mass flow and density measurement.
Technical Challenges
What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Mass Flow Meter configuration has to involve choosing tube geometry by flow range, entrained gas and hygienic needs.
Configuration
Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing tube geometry by flow range, entrained gas and hygienic needs, checked line by line against: compliance with power-industry codes and unit availability targets.
Performance
After commissioning the outcome is no temperature or pressure compensation needed, making custody transfer more credible, and the readings are now used for process tuning.
Related Products
Endress+HauserMass flowmeter 8E3B
Endress+HauserCompact mass flowmeter
Endress+HauserMass flowmeter Promass K 10
Endress+HauserMass flowmeter
Endress+HauserMass flowmeter
Endress+HauserMass flowmeter
Endress+HauserMass flowmeter
Endress+Hauser