Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

8E5B50-AAIBAEAAFAAALASAD2SHA1+AK

8E5B50-AAIBAEAAFAAALASAD2SHA1+AK
Product family: Mass flowmeter 8E5B
Mass flowmeter 8E5B
Endress+Hauser 8E5B50-AAIBAEAAFAAALASAD2SHA1+AK
Promass E 500, 8E5B50, DN50 2";Approval/Transmitter/Sensor Non-hazardous area;Power Supply AC 100...240V/DC 24V;Output/Input 1 4-20mA HART;Output/Input 2 Pulse/freq./switch output;Output/Input 3 W/o;;

Order Code:8E5B50-AAIBAEAAFAAALASAD2SHA1+AK

Name:Promass E 500, 8E5B50, DN50 2"

Configuration

CodeNameOrderSpecification
010Approval; Transmitter; SensorAANon-hazardous area
015Power SupplyIAC 100...240V/DC 24V
020Output; Input 1BA4-20mA HART
021Output; Input 2EPulse/freq./switch output
022Output; Input 3AW/o;
023Output; Input 4AW/o;
030Display; OperationF4-line illum.; touch control
035Integrated ISEM ElectronicASensor
041Transmitter HousingAAlu, coated
042Sensor Junction HousingAAlu, coated
045Cable, Sensor ConnectionL10m/30ft digital
050Electrical ConnectionAGland M20
060Meas. Tube Mat., Wetted Parts SurfaceSAStainl. steel, not polished
070Process ConnectionD2SPN40, 1.4404/316/316L, flange EN1092-1-B1
080Flow CalibrationH0.15% Mass
480Device ModelA11
500Operation Language DisplayAKChinese simplified

Configuration Explained

This is the 8E5B mass flowmeter, non-hazardous area, 100 to 230 V AC or 24 V DC supply, 4-20mA HART plus pulse, frequency and switch, 4-line backlit touch keys, coated aluminium housing, easy on-site wiring, 316L measuring tube, unpolished, size DN50, good versatility, easy to source spares, one instrument replaces several, saving investment, suitable for medium and high flow metering in chemicals and food.