Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

8G1B Coriolis mass flowmeter

8G1B Coriolis mass flowmeter
Coriolis mass flowmeter
Configurable Models 1 models
Promass G provides safe and accurate measurement of liquids and gases in high pressure applications up to 350 bar (5080 psi). Rupture disc and threaded process connections provide easy and safe integration. Combined with the smallest transmitter housing available today it delivers full performance on the smallest footprint. Designed for applications where space is a premium, Promass G 100 will be the preferred choice for system integrators, skid builders and equipment manufacturers.
Compare

Density/Concentration

Measuring Principle Coriolis
Product headline Most compact high-pressure sensor with an ultra-compact transmitter.
Accurate measurement of liquids and gases in high-pressure applications.
Sensor features Easy and safe process integration – threaded connections. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Internal threads as process connection. Process pressure up to 350 bar (5080 psi). Rupture disc available.
Transmitter features Space-saving transmitter – full functionality on the smallest footprint. Time-saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
Robust, ultra-compact transmitter housing. Pre‐configured plug connector. Local display available.
Nominal diameter range DN 8 to 25 (⅜ to 1")
Wetted materials Measuring tube: 1.4435 (316L)
Connection: 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow,
reference density
Max. measurement error Mass flow (liquid): ±0.15 %
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.75 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 18 000 kg/h (0 to 662 lb/min)
Max. process pressure 350 bar (5080 psi)
Medium temperature range –50 to +150 °C (–58 to +302 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Compact: AlSi10Mg, coated
Compact/ultra‐compact: 1.4301 (304)
Degree of protection IP66/67, type 4X enclosure
Display/Operation 4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible
Outputs 4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs None
Digital communication HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
Power supply DC 20 to 30 V
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC
Product safety CE, C-tick, EAC marking
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates CRN
Material certificates 3.1 material

Gas

Measuring Principle Coriolis
Product headline Most compact high-pressure sensor with an ultra-compact transmitter.
Accurate measurement of liquids and gases in high-pressure applications.
Sensor features Easy and safe process integration – threaded connections. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Internal threads as process connection. Process pressure up to 350 bar (5080 psi). Rupture disc available.
Transmitter features Space-saving transmitter – full functionality on the smallest footprint. Time-saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
Robust, ultra-compact transmitter housing. Pre‐configured plug connector. Local display available.
Nominal diameter range DN 8 to 25 (⅜ to 1")
Wetted materials Measuring tube: 1.4435 (316L)
Connection: 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow,
reference density
Max. measurement error Mass flow (liquid): ±0.15 %
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.75 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 18 000 kg/h (0 to 662 lb/min)
Max. process pressure 350 bar (5080 psi)
Medium temperature range –50 to +150 °C (–58 to +302 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Compact: AlSi10Mg, coated
Compact/ultra‐compact: 1.4301 (304)
Degree of protection IP66/67, type 4X enclosure
Display/Operation 4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible
Outputs 4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs None
Digital communication HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
Power supply DC 20 to 30 V
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI
Product safety CE, C-Tick
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Material certificates 3.1 material

Liquids

Measuring Principle Coriolis
Product headline Most compact high-pressure sensor with an ultra-compact transmitter.
Accurate measurement of liquids and gases in high-pressure applications.
Sensor features Easy and safe process integration – threaded connections. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Internal threads as process connection. Process pressure up to 350 bar (5080 psi). Rupture disc available.
Transmitter features Space-saving transmitter – full functionality on the smallest footprint. Time-saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
Robust, ultra-compact transmitter housing. Pre‐configured plug connector. Local display available.
Nominal diameter range DN 8 to 25 (⅜ to 1")
Wetted materials Measuring tube: 1.4435 (316L)
Connection: 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow,
reference density
Max. measurement error Mass flow (liquid): ±0.15 %
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.75 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 18 000 kg/h (0 to 662 lb/min)
Max. process pressure 350 bar (5080 psi)
Medium temperature range –50 to +150 °C (–58 to +302 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Compact: AlSi10Mg, coated
Compact/ultra‐compact: 1.4301 (304)
Degree of protection IP66/67, type 4X enclosure
Display/Operation 4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible
Outputs 4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs None
Digital communication HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
Power supply DC 20 to 30 V
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC
Product safety CE, C-Tick, EAC marking
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Material certificates 3.1 material

The Promass G enables safe and precise measurement of liquids and gases in high-pressure applications up to 350 bar (5080 psi). Safe diaphragm and threaded process connections enable simple and safe installation. Used with a small transmitter housing, it delivers full performance in a small footprint. Designed for applications with limited space, the Promass G 100 is the ideal choice for system integrators, skid builders and equipment manufacturers.

Advantages
Simple and safe process integration – threaded connection

  • Few process measuring points: multivariable measurement (flow, density, temperature)

  • Small installation space required: no upstream/downstream straight pipe length requirements

  • Small installation space required for the transmitter: full functionality in a small space

  • Time-saving on-site operation without additional software and hardware – built-in web server

  • Integrated verification – Heartbeat Technology

Field of application
The Coriolis measuring principle is unaffected by fluid properties (e.g. viscosity and density)

Precise measurement of liquids and gases in high-pressure applications

Device features

  • Internal threaded process connection

  • Process pressure: max. 350 bar (5080 psi)

  • Burst disc optional

  • Robust, ultra-compact one-piece transmitter housing

  • Pre-configured cable glands

  • Optional local display

 

Spare Parts & Accessories 23

23 spare parts · click to collapse
Order codeDescription
XPD0005-Electronic plug-in module 100 qualityMain electronic moduleEnquire
XPD0023-Display moduleUsage: Promag 100, Promass 100, Prosonic Flow E 100.Enquire
71185785Intrinsically Safe BarrierUsage: Promass 100, CNGmass, LPGmass, LNGmass.Details
71185787Safety barrier connection assemblyUsage: Promass 100, CNGmass, LPGmass, LNGmass. Consists of: 2x Connection terminal 4-Pol.Details
71185788T-DAT moduleDetails
71185789Aluminum meter coverUsage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Consists of: Cover Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover.Details
71185790Stainless Steel CoverUsage: Promass 100, Promag 100, Prosonic Flow 100. Consists of: Cover stainless 1.4301. Gasket EPDM for cover.Details
71185793Stainless Steel CoverUsage: Promag/Promass 100, Promag/Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4301, gasket EPDM for cover.Details
71266334Aluminum Cover Assembly, Glass Window, IntegratedUsage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat. Consists of: Cover with sight glass Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover.Details
71266335Aluminum Cover Assembly, Glass Window, IntegratedUsage: Promass 100, Promag 100, Prosonic Flow 100. Consists of: Cover with sight glass stainless 1.4301. Gasket EPDM for cover.Details
71266337Aluminum cover assembly, glass window, ultra-compactUsage: Promass 100, Promag 100. Consists of: Cover with sight glass stainless 1.4301. Gasket EPDM for cover.Details
71185795aluminum housing seal ringUsage: Promass 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Consists of: O-Ring 113,90 x 3,53 NBR for cover. Gasket HNBR for housing/sensor.Details
71185797Stainless steel housing seal ringUsage: Promass 100, Prosonic Flow 100. Consists of: Gasket EPDM for cover. Gasket HNBR for housing/sensor.Details
71185799Housing seal ringUsage: Promass 100, Promass 500 digital, sensor connection housing. Consists of: gasket EPDM for cover, gasket HNBR for housing/sensor.Details
50098036Explosion-proof cable glandKit 10 cable glands M20x1.5 ExDetails
71069285cable gland assemblyDetails
50098041adapterKit 10 extension M20x1.5/G 1/2"Details
71185802cable gland assemblyConsists of: 2 x Extension M20x1,5/G1/2" 1.4404. 2 x O-Ring. 2 x Sealing plug G1/2".Details
50098042adapterKit 10 extension M20x1.5/NPT 1/2"Details
71185800cable gland assemblyConsists of: 2 x Extension M20x1,5/NPT1/2" 1.4404. 2 x O-Ring. 2 x Sealing plug NPT1/2".Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
1 models · click to collapse
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Mass Flow Meter — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Mass Flow Meter, focusing on direct mass flow and density measurement.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Mass Flow Meter specification must therefore cover choosing tube geometry by flow range, entrained gas and hygienic needs.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing tube geometry by flow range, entrained gas and hygienic needs, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — no temperature or pressure compensation needed, making custody transfer more credible, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · Mass Flow Meter — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Mass Flow Meter; the focus is direct mass flow and density measurement.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing tube geometry by flow range, entrained gas and hygienic needs.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing tube geometry by flow range, entrained gas and hygienic needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means no temperature or pressure compensation needed, making custody transfer more credible, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Mass Flow Meter — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on Mass Flow Meter and the core task is direct mass flow and density measurement.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Mass Flow Meter cannot be specified generically — it calls for choosing tube geometry by flow range, entrained gas and hygienic needs.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing tube geometry by flow range, entrained gas and hygienic needs, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is no temperature or pressure compensation needed, making custody transfer more credible.

Power & Energy

Power & Energy · Mass Flow Meter — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Mass Flow Meter properly configured on the existing plant, with the aim of direct mass flow and density measurement.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Mass Flow Meter configuration has to involve choosing tube geometry by flow range, entrained gas and hygienic needs.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing tube geometry by flow range, entrained gas and hygienic needs, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is no temperature or pressure compensation needed, making custody transfer more credible, and the readings are now used for process tuning.