Technical Data
CompareDensity/Concentration
| Measuring Principle | Coriolis |
| Product headline | Robust high-pressure flowmeter with an ultra-compact transmitter. For premium accuracy at highest process pressures, fully suitable for offshore conditions. |
| Sensor features | Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 250 (3 to 10"). |
| Transmitter features | Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available. |
| Nominal diameter range | DN 80 to 150 (3 to 6") |
| Wetted materials | Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750) Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.1 (standard), 0.05 % (option) Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 800 000 kg/h (0 to 29 400 lb/min) |
| Max. process pressure | PN 250, Class 1500 |
| Medium temperature range | –40 to +205 °C (–40 to +401 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4404 (316L), highest corrosion resistance |
| Transmitter housing material | Compact: AlSi10Mg, coated Compact/ultra‐compact: 1.4404 (316L) |
| Degree of protection | Standard: IP66/67, type 4X enclosure Option: IP69 |
| Display/Operation | 4‐line backlit display available (no local operation) Configuration via web browser and operating tools possible |
| Outputs | 4‐20 mA HART (active) Pulse/frequency/switch output (passive) |
| Inputs | None |
| Digital communication | HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET |
| Power supply | DC 20 to 30 V |
| Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC |
| Product safety | CE, C-Tick |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |
Gas
| Measuring Principle | Coriolis |
| Product headline | Robust high-pressure flowmeter with an ultra-compact transmitter. For premium accuracy at highest process pressures, fully suitable for offshore conditions. |
| Sensor features | Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 250 (3 to 10"). |
| Transmitter features | Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available. |
| Nominal diameter range | DN 80 to 150 (3 to 6") |
| Wetted materials | Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750) Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) Measuring tube: 1.4539 (904L) Connection |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.1 (standard), 0.05 % (option) Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 800 000 kg/h (0 to 29 400 lb/min) |
| Max. process pressure | PN 250, Class 1500 |
| Medium temperature range | –40 to +205 °C (–40 to +401 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4404 (316L), highest corrosion resistance |
| Transmitter housing material | Compact: AlSi10Mg, coated Compact/ultra‐compact: 1.4404 (316L) |
| Degree of protection | Standard: IP66/67, type 4X enclosure Option: IP69 |
| Display/Operation | 4‐line backlit display available (no local operation) Configuration via web browser and operating tools possible |
| Outputs | 4‐20 mA HART (active) Pulse/frequency/switch output (passive) |
| Inputs | None |
| Digital communication | HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET |
| Power supply | DC 20 to 30 V |
| Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |
Liquids
| Measuring Principle | Coriolis |
| Product headline | Robust high-pressure flowmeter with an ultra-compact transmitter. For premium accuracy at highest process pressures, fully suitable for offshore conditions. |
| Sensor features | Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 150 (3 to 6"). |
| Transmitter features | Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available. |
| Nominal diameter range | DN 80 to 150 (3 to 6") |
| Wetted materials | Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750) Connection: 25Cr duplex (Super Duplex), 1.4410 (F53) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.1 (standard), 0.05 % (option) Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 800 000 kg/h (0 to 29 400 lb/min) |
| Max. process pressure | PN 250, Class 1500 |
| Medium temperature range | –40 to +205 °C (–40 to +401 °F) |
| Ambient temperature range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
| Sensor housing material | 1.4404 (316L), highest corrosion resistance |
| Transmitter housing material | Compact: AlSi10Mg, coated Compact/ultra‐compact: 1.4404 (316L) |
| Degree of protection | Standard: IP66/67, type 4X enclosure Option: IP69 |
| Display/Operation | 4‐line backlit display available (no local operation) Configuration via web browser and operating tools possible |
| Outputs | 4‐20 mA HART (active) Pulse/frequency/switch output (passive) |
| Inputs | None |
| Digital communication | HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET |
| Power supply | DC 20 to 30 V |
| Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC |
| Product safety | CE, C-Tick, EAC marking |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval, CCS approval |
| Pressure approvals and certificates | PED, CRN, AD 2000 |
| Material certificates | 3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK |
Proline Promass O 100
Coriolis flowmeter
Robust high-pressure flowmeter with ultra-compact transmitter
Advantages
Highest safety – maximum resistance to stress corrosion cracking
Fewer process measuring points – multivariable measurement (flow, density, temperature)
Space-saving installation – no inlet/outlet piping required
Space-saving transmitter – full functionality with minimal footprint
Local operation without additional software and hardware – integrated web server
Integrated verification – Heartbeat Technology
Field of application
Promass O is designed for high-precision analysis of liquids and gases under the highest process pressures in the oil and gas industry. The sensor is fully suitable for offshore conditions and resistant to stress corrosion cracking. The Promass O 100 features an ultra-compact transmitter with a small footprint and full performance for seamless system integration. Heartbeat Technology always ensures process safety.
The measuring principle is unaffected by fluid properties such as viscosity or density
High precision at the highest process pressures, fully suitable for offshore conditions
Device properties
25Cr duplex steel measuring tube, 1.4410 (UNS S32750)
Process pressure up to PN 250 (Class 1500)
Nominal diameter: DN 80 to 150 (3 to 6”)
Robust, ultra-compact transmitter housing
High degree of protection: IP69K
Local display available
Spare Parts & Accessories 23
23 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| XPD0005- | Electronic plug-in module 100 qualityMain electronic module | Enquire |
| XPD0023- | Display moduleUsage: Promag 100, Promass 100, Prosonic Flow E 100. | Enquire |
| 71185785 | Intrinsically Safe BarrierUsage: Promass 100, CNGmass, LPGmass, LNGmass. | Details |
| 71185787 | Safety barrier connection assemblyUsage: Promass 100, CNGmass, LPGmass, LNGmass. Consists of: 2x Connection terminal 4-Pol. | Details |
| 71185788 | T-DAT module | Details |
| 71185789 | Aluminum meter coverUsage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Consists of: Cover Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover. | Details |
| 71185792 | Stainless Steel CoverUsage: Promass 100. Consists of: Cover stainless 1.4404. Gasket EPDM for cover. | Details |
| 71185794 | Stainless Steel CoverUsage: Promass 100, Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4404, gasket EPDM for cover. | Details |
| 71266334 | Aluminum Cover Assembly, Glass Window, IntegratedUsage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat. Consists of: Cover with sight glass Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover. | Details |
| 71266336 | cover with glass windowUsage: Promass 100. Consists of: Cover with sight glass stainless 1.4404. Gasket EPDM for cover. | Details |
| 71266338 | cover with glass windowUsage: Promass 100. Consists of: Cover with sight glass stainless 1.4404. Gasket EPDM for cover. | Details |
| 71185795 | aluminum housing seal ringUsage: Promass 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Consists of: O-Ring 113,90 x 3,53 NBR for cover. Gasket HNBR for housing/sensor. | Details |
| 71185797 | Stainless steel housing seal ringUsage: Promass 100, Prosonic Flow 100. Consists of: Gasket EPDM for cover. Gasket HNBR for housing/sensor. | Details |
| 71185799 | Housing seal ringUsage: Promass 100, Promass 500 digital, sensor connection housing. Consists of: gasket EPDM for cover, gasket HNBR for housing/sensor. | Details |
| 50098036 | Explosion-proof cable glandKit 10 cable glands M20x1.5 Ex | Details |
| 71069285 | cable gland assembly | Details |
| 50098041 | adapterKit 10 extension M20x1.5/G 1/2" | Details |
| 71185802 | cable gland assemblyConsists of: 2 x Extension M20x1,5/G1/2" 1.4404. 2 x O-Ring. 2 x Sealing plug G1/2". | Details |
| 50098042 | adapterKit 10 extension M20x1.5/NPT 1/2" | Details |
| 71185800 | cable gland assemblyConsists of: 2 x Extension M20x1,5/NPT1/2" 1.4404. 2 x O-Ring. 2 x Sealing plug NPT1/2". | Details |
Configurator / Comparison
Source:Endress+Hauserpublic information from the website
Measuring principle video
Click to playCase Studies
Municipal Wastewater Treatment · Mass Flow Meter — Application Case
Application Context
the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Mass Flow Meter, focusing on direct mass flow and density measurement.
Process Constraints
effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Mass Flow Meter specification must therefore cover choosing tube geometry by flow range, entrained gas and hygienic needs.
Delivery Approach
Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing tube geometry by flow range, entrained gas and hygienic needs, together with stable compliance with Grade 1A discharge limits and online data reporting.
Field Results
Operation shows the benefit clearly — no temperature or pressure compensation needed, making custody transfer more credible, with confidence in this measuring point improving markedly.
Food & Beverage · Mass Flow Meter — Application Case
Customer Profile
The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Mass Flow Meter; the focus is direct mass flow and density measurement.
Key Difficulties
Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing tube geometry by flow range, entrained gas and hygienic needs.
Implementation
The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing tube geometry by flow range, entrained gas and hygienic needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.
Customer Benefit
In practice this means no temperature or pressure compensation needed, making custody transfer more credible, which cut the workload on the site maintenance team.
Chemical & Pharmaceutical · Mass Flow Meter — Application Case
Project Background
The project covers reactors, metering vessels and finished-product tanks. The work centres on Mass Flow Meter and the core task is direct mass flow and density measurement.
Operating Challenges
The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Mass Flow Meter cannot be specified generically — it calls for choosing tube geometry by flow range, entrained gas and hygienic needs.
Solution
The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing tube geometry by flow range, entrained gas and hygienic needs, with these requirements in view: Ex certification and GMP traceability of records.
Results
Since start-up the system has run steadily; the practical result is no temperature or pressure compensation needed, making custody transfer more credible.
Power & Energy · Mass Flow Meter — Application Case
Project Overview
The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Mass Flow Meter properly configured on the existing plant, with the aim of direct mass flow and density measurement.
Technical Challenges
What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Mass Flow Meter configuration has to involve choosing tube geometry by flow range, entrained gas and hygienic needs.
Configuration
Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing tube geometry by flow range, entrained gas and hygienic needs, checked line by line against: compliance with power-industry codes and unit availability targets.
Performance
After commissioning the outcome is no temperature or pressure compensation needed, making custody transfer more credible, and the readings are now used for process tuning.
Related Products
Endress+HauserMass flowmeter 8E3B
Endress+HauserCompact mass flowmeter
Endress+HauserMass flowmeter Promass K 10
Endress+HauserMass flowmeter
Endress+HauserMass flowmeter
Endress+HauserMass flowmeter
Endress+HauserMass flowmeter
Endress+Hauser