| Measuring Principle | Coriolis |
| Product headline | The refueling and distribution application flowmeter with easy sytem integration. Accurate measurement of liquefied petroleum gas in refueling and distribution applications. |
| Sensor features | Excellent operational safety – reliable under extreme ambient conditions. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space-saving installation – no in/outlet run needs. Flow rates up to 70 000 kg/h (2570 lb/min). Volume flow calculation according to API table 53. |
| Transmitter features | Space-saving transmitter – full functionality on the smallest footprint. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing. Robust, compact transmitter housing. Modbus RS485. |
| Nominal diameter range | DN 8 to 50 (³⁄₈ to 2") |
| Wetted materials | Measuring tube: 1.4539 (904L) Connection: 1.4404 (316/316L) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density |
| Max. measurement error | Mass flow (liquid): ±0.20 % Volume flow (liquid): ±0.30 % |
| Measuring range | 0 to 70 000 kg/h (0 to 2570 lb/min) |
| Max. process pressure | PN 40, Class 300 |
| Medium temperature range | –50 to +125 °C (–58 to +257 °F) |
| Ambient temperature range | –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant |
| Transmitter housing material | AlSi10Mg, coated |
| Degree of protection | IP66/67, type 4X enclosure |
| Display/Operation | No local operation Configuration via operating tools possible |
| Outputs | None |
| Inputs | None |
| Digital communication | Modbus RS485 |
| Power supply | DC 20 to 30 V |
| Hazardous area approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO |
| Product safety | CE, C-Tick |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1‐Material |
LPGmass is specially designed for LPG flow measurement in dispensing and truck loading. With its intelligent conversion function, it can measure temperature simultaneously and perform volume correction directly on site. LPGmass is the best choice for system integrators, skid manufacturers and equipment manufacturers.
Advantages
Highest operational safety: reliable measurement even under demanding conditions
Fewer process measuring points: multivariable measurement (flow, density, temperature)
Saves installation space: no upstream/downstream straight run requirements
Small transmitter footprint: all functions in the smallest space
Fast commissioning: preconfigured device
Automatic data recovery for service
Application
The measuring principle is not affected by the physical properties of the fluid (e.g. viscosity and density).
High-precision liquefied petroleum gas measurement in refueling and distribution applications.
Device characteristics
Maximum flow rate of 70 000 kg/h (2570 lb/min)
Volume flow calculation in accordance with API table 53
Robust one-piece transmitter housing
Modbus RS485
Design meets application requirements
Spare Parts & Accessories 11
11 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| XPD0019- | Electronic plug-in module CNG/LNG/LPG mass ExiMain electronic module | Enquire |
| 71185785 | Intrinsically Safe BarrierUsage: Promass 100, CNGmass, LPGmass, LNGmass. | Details |
| 71185787 | Safety barrier connection assemblyUsage: Promass 100, CNGmass, LPGmass, LNGmass. Consists of: 2x Connection terminal 4-Pol. | Details |
| 71185789 | Aluminum meter coverUsage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Consists of: Cover Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover. | Details |
| 71185795 | aluminum housing seal ringUsage: Promass 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Consists of: O-Ring 113,90 x 3,53 NBR for cover. Gasket HNBR for housing/sensor. | Details |
| 50098036 | Explosion-proof cable glandKit 10 cable glands M20x1.5 Ex | Details |
| 50098041 | adapterKit 10 extension M20x1.5/G 1/2" | Details |
| 50098042 | adapterKit 10 extension M20x1.5/NPT 1/2" | Details |
| 71276494 | Clamp fastening, screwsUsage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass, Promag/Promass 500, Promag 10, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover clamp, screw M4x16. | Details |
| 71276495 | sealing screwUsage: Transmitter housing: CNGmass, LPGmass, LNGmass, Prosonic Flow E Heat, Sensor housing: Promag 400(C), (C) = generation index C. Consists of: cover clamp, screw sealing M4x16. | Details |
| XPRFID- | Spare RFID TAGConsists of: RFID TAG, fixing wire, crimp sleeve. | Enquire |
Configurator / Comparison
Source:Endress+Hauserwebsite public information
Measuring principle video
Click to playCase Studies
Municipal Wastewater Treatment · Mass Flow Meter — Application Case
Application Context
the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Mass Flow Meter, focusing on direct mass flow and density measurement.
Process Constraints
effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Mass Flow Meter specification must therefore cover choosing tube geometry by flow range, entrained gas and hygienic needs.
Delivery Approach
Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing tube geometry by flow range, entrained gas and hygienic needs, together with stable compliance with Grade 1A discharge limits and online data reporting.
Field Results
Operation shows the benefit clearly — no temperature or pressure compensation needed, making custody transfer more credible, with confidence in this measuring point improving markedly.
Food & Beverage · Mass Flow Meter — Application Case
Customer Profile
The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Mass Flow Meter; the focus is direct mass flow and density measurement.
Key Difficulties
Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing tube geometry by flow range, entrained gas and hygienic needs.
Implementation
The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing tube geometry by flow range, entrained gas and hygienic needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.
Customer Benefit
In practice this means no temperature or pressure compensation needed, making custody transfer more credible, which cut the workload on the site maintenance team.
Chemical & Pharmaceutical · Mass Flow Meter — Application Case
Project Background
The project covers reactors, metering vessels and finished-product tanks. The work centres on Mass Flow Meter and the core task is direct mass flow and density measurement.
Operating Challenges
The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Mass Flow Meter cannot be specified generically — it calls for choosing tube geometry by flow range, entrained gas and hygienic needs.
Solution
The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing tube geometry by flow range, entrained gas and hygienic needs, with these requirements in view: Ex certification and GMP traceability of records.
Results
Since start-up the system has run steadily; the practical result is no temperature or pressure compensation needed, making custody transfer more credible.
Power & Energy · Mass Flow Meter — Application Case
Project Overview
The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Mass Flow Meter properly configured on the existing plant, with the aim of direct mass flow and density measurement.
Technical Challenges
What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Mass Flow Meter configuration has to involve choosing tube geometry by flow range, entrained gas and hygienic needs.
Configuration
Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing tube geometry by flow range, entrained gas and hygienic needs, checked line by line against: compliance with power-industry codes and unit availability targets.
Performance
After commissioning the outcome is no temperature or pressure compensation needed, making custody transfer more credible, and the readings are now used for process tuning.
Related Products
Endress+HauserMass flowmeter 8E3B
Endress+HauserCompact mass flowmeter
Endress+HauserMass flowmeter Promass K 10
Endress+HauserMass flowmeter
Endress+HauserMass flowmeter
Endress+HauserMass flowmeter
Endress+HauserMass flowmeter
Endress+Hauser