Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FWR30 Micropilot

FWR30 Micropilot
Micropilot FWR30
Configurable Models 1 models
Product page of Micropilot FWR30. The device is a battery-powered 80 GHz radar sensor for reliable non-contact level measurement in IIoT applications.
Compare

Continuous / Liquids

Measuring Principle Level radar
Characteristic / Application Applications in all industries
Mobile and stationary storage tanks
Specialities Commissioning and operation via digital services like "Netilion Value" or "SupplyCare Hosting"
Supply / Communication Battery powered
Mobile connectivity with NB-IoT, LTE-M or 2G (fallback)
Frequency 80 GHz
Accuracy ±2 mm (0.08 in)
Process temperature -20°C...+60°C (-4°F…+140°F)
Main wetted parts Housing: plastic PBT/ PC
Process connection None
Max. measurement distance 30 m (98 ft)
Communication Wireless
Mobile connectivity with NB-IoT, LTE-M or 2G (fallback)
Options Mounting bracket IBC/ pipe
Mounting bracket wall/ ceiling
Application limits DK <1.9
Metallized plastic tanks

Continuous / Solids

Measuring Principle Level radar solid
Characteristic / Application Applications in all industries
Mobile and stationary plastic and metal tanks (IBC tanks, storage silos)
Reliable non-contact level measurement of solids in metal- and plastic containers
Specialities Commissioning and operation via digital services like "Netilion Value", "Netilion Inventory" or "SupplyCare Hosting"
Supply / Communication Battery powered
Mobile connectivity with NB-IoT, LTE-M or
2G (fallback)
Frequency 80 GHz
Accuracy ±5 mm (0.20 in)
Process temperature -20°C...+60°C (-4°F…+140°F)
Main wetted parts Housing: plastic PBT/ PC
Process connection Threads:
G 1 1/2", NPT 1 1/2"
Max. measurement distance 30 m (98 ft)
Communication Wireless
Mobile connectivity with NB-IoT, LTE-M or
2G (fallback)
Options Mounting bracket IBC/ pipe
Mounting bracket wall/ ceiling
Application limits DK <1.9
Non-invasive measurement in metallized plastic tanks

Simple to start, easy to use. Our Industrial Internet of Things (IIoT) radar is a smart level transmitter with advanced technology and high cost-effectiveness. When combined with a digital service (Netilion Value, Netilion Inventory or SupplyCare Host), the battery-powered wireless radar level sensor ensures reliable remote level monitoring. The certified security solution provides asset and inventory status information anytime, anywhere.

Advantages
Fully transparent information on liquid storage and transport
A simple solution covering the entire process from procurement to operation
Flexible selection of digital service products for secure data transmission
Information can be queried anytime, anywhere

Application areas
Level measurement and real-time monitoring of mobile plastic tanks (e.g. IBC containers)
Remote level measurement and inventory management of plastic tanks installed outside the plant or at different locations
Level measurement and inventory management of mobile and stationary plastic tanks in the production process, eliminating power supply difficulties, making testing faster and more convenient, and making safe inventory information more transparent

 

Spare Parts & Accessories 2

2 spare parts · click to collapse
Order codeDescription
71447849Mounting bracket, IBC/pipeline, vertical mountingMaterial: 304. Usage: Mounting FWR30.Details
71447853Mounting bracket, wall/top mountingMaterial: 304. Usage: Mounting FWR30.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories / Spare parts

 

   

Measuring principle video

Click to play

Source:Endress+Hauserpublic information from the website

1 models · click to collapse
All documents for this model
6 documents · click to expand
BA

BA Micropilot FWR30 Chinese

Rev. 0826 32 pages
Preview
BA

BA Micropilot FWR30 for dynamic water level monitoring Chinese

Rev. 0126 36 pages
Preview
BA

BA Micropilot FWR30 English

Rev. 0826 32 pages
Preview
BA

BA Micropilot FWR30 for dynamic water level monitoring English

Rev. 0126 36 pages
Preview
TI

TI Micropilot FWR30 Chinese

Rev. 1126 20 pages
Preview
TI

TI Micropilot FWR30 English

Rev. 1126 24 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · radar — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted radar properly configured on the existing plant, with the aim of continuous radar level measurement of liquids and solids.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the radar configuration has to involve choosing antenna type by dielectric constant, range and process connection.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing antenna type by dielectric constant, range and process connection, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is reliable under heavy dust and vapour, reducing manual dipping, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · radar — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was continuous radar level measurement of liquids and solids.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing antenna type by dielectric constant, range and process connection.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing antenna type by dielectric constant, range and process connection, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — reliable under heavy dust and vapour, reducing manual dipping, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · radar — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from radar , focusing on continuous radar level measurement of liquids and solids.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The radar specification must therefore cover choosing antenna type by dielectric constant, range and process connection.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing antenna type by dielectric constant, range and process connection, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — reliable under heavy dust and vapour, reducing manual dipping, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · radar — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is radar ; the focus is continuous radar level measurement of liquids and solids.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing antenna type by dielectric constant, range and process connection.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing antenna type by dielectric constant, range and process connection, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means reliable under heavy dust and vapour, reducing manual dipping, which cut the workload on the site maintenance team.