Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

SBC600 bunker metering computer

SBC600 bunker metering computer
SBC600 bunker metering computer
The Bunker Metering Computer SBC600 collects, visualizes and stores bunkering data from all involved devices. Out of that data the Bunker Metering Computer will create batch tickets and metering profiles. The measuring system immediately reports irregularities during bunkering, making it possible to intervene quickly. The Bunker Metering Computer SBC600 is an integral part of the complete Bunker Metering Solution delivered by Endress+Hauser.

The bunkering computer collects, displays and stores the bunkering data of all relevant equipment. Based on this data, the bunkering computer generates batch tickets and metering record files. The measuring system reports violations during the bunkering process in real time, enabling rapid intervention.
The bunkering computer SBC600 is part of the complete Endress+Hauser bunkering measurement solution.

Advantages
Continuous bidirectional mass flow measurement using Endress+Hauser Coriolis mass flowmeters.

  • Patented bidirectional flow measurement offers the highest measuring accuracy (even under demanding conditions, e.g. stripping), the highest application safety and the highest measuring suitability.

  • The metering record file enables immediate intervention in excessive stripping or overfilling. As a result, no additional time is required for costly intervention in non-transparent bunkering operations.

  • The custody transfer certified system provides globally recognized measuring results. The audit trail ensures transparency and traceability of setting changes.

  • The built-in 12” operating panel with clear display and touchscreen (HMI) immediately displays error messages, ensuring safe operation.

Areas of application
The intuitive operator interface displays error messages in good time throughout the bunkering process, ensuring optimized control and safe operation. The bunkering computer SBC600 offers maximum ease of operation. Operators can easily handle the entire bunkering process. The custody transfer certified system is globally recognized, and the sealed components prevent accidental tampering.

 

Spare Parts & Accessories 15

15 spare parts · click to collapse
Order codeDescription
71292986SBC600 CPUDetails
71292987SBC600 ASCII ModuleDetails
71292988SBC600 Bus RTU ModuleDetails
71292989SBC600 Analog Signal InputDetails
71293014SBC600 Panel PrintingDetails
71293015SBC600 GatewayDetails
71293016SBC600 Thermal PaperDetails
71336149label panelAccompanying product has to be specified in the production memo. Size (mm): 85 x 73 x 1.5 (H x W x D)Details
71337810Service LicenseRockwell Studio5000 Service Edition licenceDetails
71337811Service License Hardware KeyDetails
71391293All-in-One Update ToolDetails
71391294DC power supplyDetails
71391295DC Redundant Power SupplyDetails
71718995SBC600 Panel PC (WIN10IoT)Details
71776401SBC600 Ethernet-Modbus RTU GatewayDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source: public information from the Endress+Hauser website

All documents for this model
3 documents · click to expand
BA

BA 船舶加油计量仪SBC600 Chinese

Rev. 0922 76 pages
Preview
BA

BA Bunker Metering Computer SBC600 English

Rev. 1125 80 pages
Preview
BA

BA Off-Loading Flow Computer SBC600 English

Rev. 0525 84 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · data manager — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was centralised data acquisition, storage and forwarding to management platforms.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means selected by channel count, storage depth and forwarding protocol.

What We Did

We took a system components range approach — supplying as a full cabinet and signal-chain configuration. Delivery was built around selected by channel count, storage depth and forwarding protocol, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — automatic backfill after outages, greatly improving data completeness, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · data manager — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from data manager, focusing on centralised data acquisition, storage and forwarding to management platforms.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The data manager specification must therefore cover selected by channel count, storage depth and forwarding protocol.

Delivery Approach

Delivery was handled as the system components range — supplying as a full cabinet and signal-chain configuration. Execution centred on selected by channel count, storage depth and forwarding protocol, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — automatic backfill after outages, greatly improving data completeness, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · data manager — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is data manager; the focus is centralised data acquisition, storage and forwarding to management platforms.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with selected by channel count, storage depth and forwarding protocol.

Implementation

The scope ran through the system components range: supplying as a full cabinet and signal-chain configuration. Technically it hinges on selected by channel count, storage depth and forwarding protocol, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means automatic backfill after outages, greatly improving data completeness, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · data manager — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on data manager and the core task is centralised data acquisition, storage and forwarding to management platforms.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So data manager cannot be specified generically — it calls for selected by channel count, storage depth and forwarding protocol.

Solution

The Ainstru engineering team worked through the system components range: supplying as a full cabinet and signal-chain configuration. The configuration involves selected by channel count, storage depth and forwarding protocol, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is automatic backfill after outages, greatly improving data completeness.