Promass E has a long standing reputation as a cost efficient solution for Coriolis applications. Combined with the proven Promass 80 transmitter with push buttons, Promass 80E offers highly accurate measurement of liquids and gases for a wide range of standard applications.
Compare

Density

Measuring Principle Coriolis
Characteristic / Application An alternative to conventional volumetric flowmeters, this flowmeter has a low "cost of ownership".
Ambient temperature -20...+65°C
(-4...+140°F)
Process temperature -40...+125°C
(-40...+257°F)
Process pressure PN 40...100
Cl150...600
JIS 10...63K
Wetted parts 904L/1.4539
Output 4...20mA
Pulse/Frequency
Status
Certificates / Approvals ATEX
FM
CSA

Density/Concentration

Measuring Principle Coriolis
Product headline The flowmeter for minimized cost of ownership with a compact or remote transmitter. Highly accurate measurement of liquids and gases for a wide range of standard applications.
Sensor features Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Compact dual‐tube system. Medium temperature up to +140 °C (+284 °F).
Transmitter features Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
Nominal diameter range DN 8 to 80 (⅜ to 3")
Wetted materials Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error Mass flow (liquid): ±0.20 % (standard)
Volume flow (liquid): ±0.20 %
Mass flow (gas): ±0.75 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 180 000 kg/h (0 to 6600 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range –40 to +140 °C (–40 to +284 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
Degree of protection IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation 2‐line backlit display with push buttons
Configuration via local display and operating tools possible
Outputs 3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Inputs Status input
Digital communication HART
PROFIBUS PA
Power supply DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals ATEX, IECEx, FM, CSA, NEPSI
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Marine approvals and certificates Marine approval
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A

Gas

Measuring Principle Coriolis
Product headline The flowmeter for minimized cost of ownership with a compact or remote transmitter. Highly accurate measurement of liquids and gases for a wide range of standard applications.
Sensor features Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Compact dual‐tube system. Medium temperature up to +140 °C (+284 °F).
Transmitter features Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
Nominal diameter range DN 8 to 80 (⅜ to 3")
Wetted materials Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error Mass flow (liquid): ±0.20 % (standard)
Volume flow (liquid): ±0.20 %
Mass flow (gas): ±0.75 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 180 000 kg/h (0 to 6600 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range –40 to +140 °C (–40 to +284 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
Degree of protection IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation 2‐line backlit display with push buttons
Configuration via local display and operating tools possible
Outputs 3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Inputs Status input
Digital communication HART
PROFIBUS PA
Power supply DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals ATEX, IECEx, FM, CSA, NEPSI
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine
PED, CRN
3-A
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Marine approvals and certificates Marine approval
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A

Liquids

Measuring Principle Coriolis
Product headline The flowmeter for minimized cost of ownership with a compact or remote transmitter. Highly accurate measurement of liquids and gases for a wide range of standard applications.
Sensor features Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Compact dual‐tube system. Medium temperature up to +140 °C (+284 °F).
Transmitter features Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
Nominal diameter range DN 8 to 80 (⅜ to 3")
Wetted materials Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error Mass flow (liquid): ±0.20 % (standard)
Volume flow (liquid): ±0.20 %
Mass flow (gas): ±0.75 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 180 000 kg/h (0 to 6600 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range –40 to +140 °C (–40 to +284 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
Degree of protection IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation 2‐line backlit display with push buttons
Configuration via local display and operating tools possible
Outputs 3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Inputs Status input
Digital communication HART
PROFIBUS PA
Power supply DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals ATEX, IECEx, FM, CSA, NEPSI
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine
PED, CRN
3-A
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Marine approvals and certificates Marine approval
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A

The Promass E flowmeter series uses the Coriolis measuring principle, is cost-effective and has earned an excellent reputation. With the Promass 80 transmitter, it is used for precise measurement of liquid and gas flow in a wide range of applications.

Benefits
Modular device and operating concept for greater efficiency.
Optional batching and concentration measurement software as expansion functions.
Diagnostics and data backup for improved process quality.
Integrated multivariable flowmeter.
Balanced dual-tube measuring system design with excellent vibration resistance.
Robust design unaffected by external pipeline forces.
No inlet/outlet straight runs required, easy installation.

Applications
The Coriolis mass flow measuring principle is independent of the physical properties of the fluid, such as viscosity and density.
Performance characteristics
– Mass flow (liquid): ±0.20% o.r.
– Mass flow (gas): ±0.75% o.r. 
Process temperature up to +140 °C (+284 °F)
Safety diaphragm (optional)
Guaranteed product quality, compliant with CIP/SIP hygiene standards
Low maintenance costs
Robust field (aluminum) housing with exclusive patents and 67 years of expertise
Relevant approvals for the food/hygiene industry/sector
3-A approval

 

Spare Parts & Accessories 85

85 spare parts · click to collapse
Order codeDescription
50098557Power board220V = 85-260VACDetails
71039431Power boardHE = harsh environment 220V = 85-260VACDetails
50098558Explosion-proof power supply board220V = 85-260VACDetails
71039432Explosion-proof power supply boardHE = harsh environment 220V = 85-260VACDetails
71097758explosion-proof amplifier board220V = 85-260VACDetails
71097760*** Explosion-proof Power Supply Board220V = 85-260VAC HE = harsh environmentDetails
50098565Power board24V = 20-55VAC / 16-62VDCDetails
71039434Power boardHE = harsh environment 24V = 20-55VAC / 16-62VDCDetails
50098566Explosion-proof power supply boardKit P.s.b. 40/8X/65 20-55AC 16-62DC ExDetails
71039436Explosion-proof power supply boardHE = harsh environment 24V = 20-55VAC / 16-62VDCDetails
71097759Explosion-proof power supply board24V = 20-55VAC/16-62VDCDetails
71097761*** Explosion-proof Power Supply Board24V = 20-55VAC/16-62VDC HE = harsh environmentDetails
50094002fuseKit 10 fuses 250 VAC T800 MADetails
50094003fuseKit Bus/connec.b.5X/40/8X/65 field hous.Details
50106094*** Explosion-proof Amplifier BoardLanguage: FR, ES, IT, NL, PT, DE, ENDetails
71039405*** Explosion-proof Amplifier BoardLanguage: FR, ES, IT, NL, PT, DE, EN HE = harsh environmentDetails
50106095*** Explosion-proof Amplifier BoardKit meas. amplifier PMASS 80 EES EXDetails
71039406*** Explosion-proof Amplifier BoardLanguage: SV, FI, NO, RU, PL, CS, EN HE = harsh environmentDetails
50106096*** Explosion-proof Amplifier BoardKit meas. amplifier PMASS 80 SEA EXDetails
71039407*** Explosion-proof Amplifier BoardLanguage: JA, ID, EN HE = harsh environmentDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Measuring principle video

Click to play
All documents for this model
12 documents · click to expand
BA

Proline Promass 80 HART Operating Instructions Chinese

HART Rev. 1312 114 pages
Preview
BA

Proline Promass 80 HART Operating Instructions English

HART Rev. 1312 114 pages
Preview
BA

Proline Promass 80 PROFIBUS PA Operating Instructions English

PROFIBUS-PA Rev. 1312 130 pages
Preview
BA

Proline Promass 80 English

Rev. 0908 70 pages
Preview
BA

Proline Promass 80 PROFIBUS PA Operating Instructions English

PROFIBUS-PA Rev. 0610 134 pages
Preview
BA

Proline Promass 80 PROFIBUS PA Description of Device Functions English

PROFIBUS-PA Rev. 0610 44 pages
Preview
BA

Proline Promass 80 HART Operating Instructions English

HART Rev. 0310 118 pages
Preview
BA

Promass 80 Device Functions English

58 pages
Preview
BA

Promass 80 PROFIBUS-PA Device Functions English

PROFIBUS-PA 120 pages
Preview
TI

技术资料 Proline Promass 80E, 83E Chinese

Rev. 1515 52 pages
Preview
TI

Proline Promass 80E, 83E Technical Information English

Rev. 1618 52 pages
Preview
TI

Proline Promass 80E, 83E Technical Information (SI units) English

Rev. 1009 48 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Mass Flow Meter — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Mass Flow Meter, focusing on direct mass flow and density measurement.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Mass Flow Meter specification must therefore cover choosing tube geometry by flow range, entrained gas and hygienic needs.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing tube geometry by flow range, entrained gas and hygienic needs, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — no temperature or pressure compensation needed, making custody transfer more credible, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · Mass Flow Meter — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Mass Flow Meter; the focus is direct mass flow and density measurement.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing tube geometry by flow range, entrained gas and hygienic needs.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing tube geometry by flow range, entrained gas and hygienic needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means no temperature or pressure compensation needed, making custody transfer more credible, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Mass Flow Meter — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on Mass Flow Meter and the core task is direct mass flow and density measurement.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Mass Flow Meter cannot be specified generically — it calls for choosing tube geometry by flow range, entrained gas and hygienic needs.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing tube geometry by flow range, entrained gas and hygienic needs, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is no temperature or pressure compensation needed, making custody transfer more credible.

Power & Energy

Power & Energy · Mass Flow Meter — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Mass Flow Meter properly configured on the existing plant, with the aim of direct mass flow and density measurement.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Mass Flow Meter configuration has to involve choosing tube geometry by flow range, entrained gas and hygienic needs.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing tube geometry by flow range, entrained gas and hygienic needs, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is no temperature or pressure compensation needed, making custody transfer more credible, and the readings are now used for process tuning.