Technical Data
CompareDensity
| Measuring Principle | Coriolis |
| Characteristic / Application | The single-tube system for highest measuring accuracy with minimal flow rates. |
| Ambient temperature | -20...+65°C (-4...+140°F) |
| Process temperature | -50...+200°C (-58...+392°F) |
| Process pressure | PN 16...400 Cl 150...600 JIS 10...63K |
| Wetted parts | 904L/1.4539 Alloy C22/2.4602 |
| Output | 4...20mA Pulse/Frequency (10KHz), active/passive Relays/Status |
| Certificates / Approvals | ATEX FM CSA |
Density/Concentration
| Measuring Principle | Coriolis |
| Product headline | The single‐tube flowmeter for smallest quantities with extended transmitter functionality. Measuring accurately smallest quantities of liquids and gases for continuous process control. |
| Sensor features | Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi). |
| Transmitter features | Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version. |
| Nominal diameter range | DN 1 to 4 (¹⁄₂₄ to ¹⁄₈") |
| Wetted materials | Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 450 kg/h (0 to 16.5 lb/min) |
| Max. process pressure | PN 40, Class 300, 20K, 400 bar (5800 psi) |
| Medium temperature range | –50 to +200 °C (–58 to +392 °F) |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant |
| Transmitter housing material | Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast |
| Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
| Display/Operation | 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
| Outputs | 4 modular outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) Relay |
| Inputs | 2 modular inputs: Status 0‐20 mA (active)/4‐20 mA (active/passive) |
| Digital communication | HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Pressure approvals and certificates | CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A |
Gas
| Measuring Principle | Coriolis |
| Product headline | The single‐tube flowmeter for smallest quantities with extended transmitter functionality. Measuring accurately smallest quantities of liquids and gases for continuous process control. |
| Sensor features | Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi). |
| Transmitter features | Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version. |
| Nominal diameter range | DN 1 to 4 (¹⁄₂₄ to ¹⁄₈") |
| Wetted materials | Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 450 kg/h (0 to 16.5 lb/min) |
| Max. process pressure | PN 40, Class 300, 20K, 400 bar (5800 psi) |
| Medium temperature range | –50 to +200 °C (–58 to +392 °F) |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant |
| Transmitter housing material | Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast |
| Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
| Display/Operation | 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
| Outputs | 4 modular outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) Relay |
| Inputs | 2 modular inputs: Status 0‐20 mA (active)/4‐20 mA (active/passive) |
| Digital communication | HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI |
| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL CRN 3-A |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Pressure approvals and certificates | CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A |
Liquids
| Measuring Principle | Coriolis |
| Product headline | The single‐tube flowmeter for smallest quantities with extended transmitter functionality. Measuring accurately smallest quantities of liquids and gases for continuous process control. |
| Sensor features | Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi). |
| Transmitter features | Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version. |
| Nominal diameter range | DN 1 to 4 (¹⁄₂₄ to ¹⁄₈") |
| Wetted materials | Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L) |
| Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. measurement error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm³ |
| Measuring range | 0 to 450 kg/h (0 to 16.5 lb/min) |
| Max. process pressure | PN 40, Class 300, 20K, 400 bar (5800 psi) |
| Medium temperature range | –50 to +200 °C (–58 to +392 °F) |
| Ambient temperature range | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant |
| Transmitter housing material | Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast |
| Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
| Display/Operation | 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
| Outputs | 4 modular outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) Relay |
| Inputs | 2 modular inputs: Status 0‐20 mA (active)/4‐20 mA (active/passive) |
| Digital communication | HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP |
| Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
| Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI |
| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL CRN 3-A |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR |
| Pressure approvals and certificates | CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | 3-A |
The Promass A series Coriolis flowmeter is renowned for its high-accuracy measurement of the smallest liquid and gas flow rates in both high-pressure and low-pressure applications. In combination with the Promass 83 transmitter with touch control, four-line display and extended functions (such as filling, dosing, concentration measurement or advanced diagnostics), Promass 83A is widely used for the precise measurement of the smallest liquid and gas flow rates.
Benefits
Modular design and operating concept for greater efficiency
Optional batching and concentration measurement software as extended functions
Diagnostics and data backup functions improve process quality
Integrated multivariable flow measurement
Balanced single-tube measuring system unaffected by vibration
Robust design, unaffected by external pipe forces
No inlet/outlet runs required, easy installation
Application
The Coriolis measuring principle is independent of the physical properties of the fluid, such as viscosity and density.
Suitable for continuous measurement of very small flow rates in filling and dosing.
Extremely precise measurement of liquids and gases, e.g. emulsions, additives, flavorings, insulin, and high-pressure and low-pressure gases.
Fluid temperature up to +200 °C (+392 °F)
Process pressure up to 400 bar (5800 psi)
Hazardous area approvals
ATEX, FM, CSA, TIIS, IECEx, NEPSI
Spare Parts & Accessories 117
117 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 50098557 | Power board220V = 85-260VAC | Details |
| 71039431 | Power boardHE = harsh environment 220V = 85-260VAC | Details |
| 50098558 | Explosion-proof power supply board220V = 85-260VAC | Details |
| 71039432 | Explosion-proof power supply boardHE = harsh environment 220V = 85-260VAC | Details |
| 50098565 | Power board24V = 20-55VAC / 16-62VDC | Details |
| 71039434 | Power boardHE = harsh environment 24V = 20-55VAC / 16-62VDC | Details |
| 50098566 | Explosion-proof power supply boardKit P.s.b. 40/8X/65 20-55AC 16-62DC Ex | Details |
| 71039436 | Explosion-proof power supply boardHE = harsh environment 24V = 20-55VAC / 16-62VDC | Details |
| 50094002 | fuseKit 10 fuses 250 VAC T800 MA | Details |
| 50094003 | fuseKit Bus/connec.b.5X/40/8X/65 field hous. | Details |
| 50106097 | *** Explosion-proof Amplifier BoardKit meas. amplifier PMASS 83 WEA EX | Details |
| 71039409 | *** Explosion-proof Amplifier BoardLanguage: FR, ES, IT, NL, PT, DE, EN HE = harsh environment | Details |
| 50106098 | *** Explosion-proof Amplifier BoardKit meas. amplifier PMASS 83 EES EX | Details |
| 71039410 | *** Explosion-proof Amplifier BoardLanguage: SV, FI, NO, RU, PL, CS, EN HE = harsh environment | Details |
| 50106099 | *** Explosion-proof Amplifier BoardKit meas. amplifier PMASS 83 SEA EX | Details |
| 71039411 | *** Explosion-proof Amplifier BoardLanguage: JA, ID, EN HE = harsh environment | Details |
| 50108135 | *** Explosion-proof Amplifier BoardKit meas. amplifier Pmass 83 CN EX | Details |
| 71039412 | *** Explosion-proof Amplifier BoardLanguage: ZH, EN HE = harsh environment | Details |
| 71261695 | *** Explosion-proof Amplifier BoardLanguage: DE+FR+IT+ES+EN | Details |
| 71261696 | *** Explosion-proof Amplifier BoardLanguage: DE+FR+IT+ES+EN HE = harsh environment | Details |
Configurator / Comparison
Measuring principle video
Click to playManuals & Documents 12
All documents for this model12 documents · click to expand
Proline Promag 83 HART 操作手册 Chinese
Proline Promass 83 HART Operating Instructions English
Proline Promass 83 FOUNDATION Fieldbus Operating Instructions English
Proline Promass 83 Modbus RS485 Operating Instructions English
Proline Promass 83 PROFIBUS DP/PA Operating Instructions English
Proline Promass 83 HART Description of Device Functions English
Proline Promass 83 MODBUS RS485 Description of Device Functions English
Proline Promass 83 FOUNDATION Fieldbus Device Functions English
Proline Promass 83 PROFIBUS DP/PA Description of Device Functions English
Proline Promass 83 HART Description of Device Functions English
Proline Promass 83 MODBUS RS485 Operating Instructions English
Proline Promass 83 FOUNDATION Fieldbus Operating Instructions English
Product Videos
View allCase Studies
Municipal Wastewater Treatment · Mass Flow Meter — Application Case
Application Context
the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Mass Flow Meter, focusing on direct mass flow and density measurement.
Process Constraints
effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Mass Flow Meter specification must therefore cover choosing tube geometry by flow range, entrained gas and hygienic needs.
Delivery Approach
Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing tube geometry by flow range, entrained gas and hygienic needs, together with stable compliance with Grade 1A discharge limits and online data reporting.
Field Results
Operation shows the benefit clearly — no temperature or pressure compensation needed, making custody transfer more credible, with confidence in this measuring point improving markedly.
Food & Beverage · Mass Flow Meter — Application Case
Customer Profile
The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Mass Flow Meter; the focus is direct mass flow and density measurement.
Key Difficulties
Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing tube geometry by flow range, entrained gas and hygienic needs.
Implementation
The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing tube geometry by flow range, entrained gas and hygienic needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.
Customer Benefit
In practice this means no temperature or pressure compensation needed, making custody transfer more credible, which cut the workload on the site maintenance team.
Chemical & Pharmaceutical · Mass Flow Meter — Application Case
Project Background
The project covers reactors, metering vessels and finished-product tanks. The work centres on Mass Flow Meter and the core task is direct mass flow and density measurement.
Operating Challenges
The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Mass Flow Meter cannot be specified generically — it calls for choosing tube geometry by flow range, entrained gas and hygienic needs.
Solution
The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing tube geometry by flow range, entrained gas and hygienic needs, with these requirements in view: Ex certification and GMP traceability of records.
Results
Since start-up the system has run steadily; the practical result is no temperature or pressure compensation needed, making custody transfer more credible.
Power & Energy · Mass Flow Meter — Application Case
Project Overview
The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Mass Flow Meter properly configured on the existing plant, with the aim of direct mass flow and density measurement.
Technical Challenges
What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Mass Flow Meter configuration has to involve choosing tube geometry by flow range, entrained gas and hygienic needs.
Configuration
Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing tube geometry by flow range, entrained gas and hygienic needs, checked line by line against: compliance with power-industry codes and unit availability targets.
Performance
After commissioning the outcome is no temperature or pressure compensation needed, making custody transfer more credible, and the readings are now used for process tuning.
Related Products
Endress+HauserMass flowmeter 8E3B
Endress+HauserCompact mass flowmeter
Endress+HauserMass flowmeter Promass K 10
Endress+HauserMass flowmeter
Endress+HauserMass flowmeter
Endress+HauserMass flowmeter
Endress+HauserMass flowmeter
Endress+Hauser