Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

8U5B 500 Coriolis flowmeter

8U5B 500 Coriolis flowmeter
500 Coriolis flowmeter
Plug and measure: The first single-use flowmeter with premium performance and cGMP compliance. For biotech applications in life sciences.
Compare

Liquids

Measuring Principle Coriolis
Product headline Single-use specialist for Biotech applications, with a remote version with up to 4 I/Os.
Modern fieldbus communication protocols (2-wire).
Highest measurement performance for liquids in single-use processes for the Life Sciences Industry.
Sensor features One sensor fits all DN – single variant with 4 disposable line sizes provides highest turndown ratio . One-hand mounting of disposable – easy
commissioning due to intuitive clamping mechanism. Mounting angle - self drainabillity or air bubble escape.
Disposable made of 1.4435 (316L) and polycarbonate. Fully traceable cGMP compliance. One sensor fits four line sizes: ¹⁄₈ to 1".
Transmitter features Full access to process and diagnostic information –
numerous, freely combinable I/Os and Ethernet. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
Nominal diameter range ¹⁄₈" to 1"
Wetted materials Measuring tubes: Stainless steel 1.4435, 316L
Hose connection nipple: Makrolon Rx 1805 polycarbonate
Measured variables Mass, density, temperature
Max. measurement error Mass flow (liquid): ±0.5%
Measuring range 0 to 75 kg/min (0 to 165,3 lb/min)
Max. process pressure 6 bar (87 psi)
Medium temperature range 3 to 60°C (37.4 to 140°F)
Ambient temperature range 5 to 40°C (41 to 104°F)
Transmitter housing material Aluminum, AlSi10Mg, coated
Degree of protection Transmitter: IP66/67, Type 4X enclosure
Sensor: IP54
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs "4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output"
Inputs Status input
4-20 mA input
Digital communication Modbus RS485, PROFINET over Ethernet-APL
Power supply AC 100 to 230 V / DC 24 V (non-hazardous area)
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Hygienic approvals and certificates cGMP compliance, ASME BPE, BPOG, FDA

Proline Promass U 500 Coriolis flowmeter
The first single-use flowmeter for biotechnological applications, with outstanding performance, cGMP compliance and up to 4 I/Os
Advantages
First-class measuring accuracy – Coriolis technology with multivariable measurement

Highest turndown ratio – one sensor fits all tube sizes of the single-use system

cGMP compliance – designed according to the latest standards and guidelines, with the required properties and documentation

Simple, fast commissioning – one-hand installation and automatic calibration data transfer

Self-draining or bubble escape – thanks to different installation angles

No on-site calibration – automatic verification using integrated Heartbeat Technology

Digital integration – communication protocol based on modern single-pair Ethernet
Field of application
The Promass U 500 is the ideal single-use flowmeter for biopharmaceutical applications in the life sciences industry. It represents the response to the shift from multi-purpose equipment to single-use equipment and from batch to continuous manufacturing. The Promass U 500 provides multivariable measurement with higher reliability and accuracy and complies with cGMP. The flowmeter is particularly suitable for upstream and downstream applications in monoclonal antibody (mAb) processes.

The sensor comprises a single-use part (available in four tube sizes) and a permanently installed base unit that fits all tube sizes. Heartbeat Technology automatically identifies the flow range after installation and verifies the validity of the factory calibration. This simplifies commissioning and eliminates on-site calibration. The transmitter is equipped with a built-in web server, WLAN and up to 4 I/Os, is easy to operate and provides additional process and device information.

Spare Parts & Accessories 27

27 spare parts · click to collapse
Order codeDescription
XPD0101-ISEM, Promass U 500Usage: Valid for approvals acc. feature 030. Consists of: ISEM (sensor electronic module) V312-02.Enquire
XPD0037-I/O moduleUsage: Proline 300/500Enquire
XPD0038-I/O moduleUsage: Proline 300/500Enquire
XPD0031-Display moduleUsage: Proline 300/500, DKX001.Enquire
71323009Power supply assemblyUsage: Promag/Promass/Prosonic Flow/ t-mass/Teqwave MW 300/500 digital, Non-haz, Zone 2, transmitter housing, electronic compartment.Details
71323013Main electronics connection board assembly, non-explosion-proof, 500 digitalUsage: Promag/Promass/Prosonic Flow/ t-mass/Teqwave MW 500 digital, transmitter housing, electronic compartment.Details
71635381Kit backplane incl. S-DAT, Promass U 500Usage: Promass U 500, sensor housing.Details
71185788T-DAT moduleDetails
71635382Kit ribbon cable, Promass U 500Usage: Promass U 500, sensor housing. Consists of: ribbon cable 1x16pol., L= 123mm.Details
71635383Infrared sensor kit, Promass U 500Usage: Promass U 500, sensor housing.Details
71635384Kit barcode scanner, Promass U 500Usage: Promass U 500, sensor housing.Details
71323077Terminal Block AssemblyUsage: transmitter housing Alu/polycarbonate, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus, Profinet APL, Modbus TCP APL. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.Details
71327820Terminal Block AssemblyUsage: transmitter housing Alu/polycarbonate, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol., 1x connection terminal 6-Pol.Details
71384170Promag400/500 coverUsage: Prosonic Flow 400, Promag 400(C), (C) = generation index C, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, transmitter housing Alu. Consists of: cover Alu complete included O-Ring 196,40x3,53 VMQ, default and -50oC/-58oF, wire with screw lock 1,5x150.Details
71278078cover seal ringUsage: Prosonic Flow 400, Promag 400(C), (C) = generation index C, Promag/Promass/Prosonic Flow/t-mass/ Teqwave MW 500 digital, transmitter housing Alu. Consists of: 10x O-Ring 196,40x3,53 VMQ, default and -50oC/-58oF.Details
71635385Kit cover gasket, sensor, Promass U 500Usage: Promass U 500, sensor housing. Consists of: cover gasket EPDM, 6x screws M3x6.Details
71635386Kit plug M12x1, Promass U 500Usage: Promass U 500, sensor housing.Details
71450719Adapter M12, RJ45, L= 80 mm (for t-mass F 300/50)Usage: Proline 300/500.Details
71635387Kit of 2 mounting wedges, Promass U 500Usage: Promass U 500, sensor housing. Consists of: mounting wedge for venting/draining.Details
71635388Kit of 5 closure caps, Promass U 500Usage: Promass U 500, sensor housing.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
Diagnostic codes(91 条)→
All documents for this model
8 documents · click to expand
BA

BA Proline Promass U 500 Chinese

Rev. 0425 298 pages
Preview
BA

BA Proline Promass U 500 Chinese

Rev. 0325 226 pages
Preview
BA

BA Proline Promass U 500 Chinese

Rev. 0225 198 pages
Preview
BA

BA Proline Promass U 500 English

Rev. 0425 322 pages
Preview
BA

BA Proline Promass U 500 English

Rev. 0325 252 pages
Preview
BA

BA Proline Promass U 500 English

Rev. 0225 214 pages
Preview
TI

TI Proline Promass U 500 Chinese

Rev. 0325 60 pages
Preview
TI

TI Proline Promass U 500 English

Rev. 0325 64 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Mass Flow Meter — Application Case

Application Context

the inlet, biological and outlet stages of a municipal plant is a typical Municipal Wastewater Treatment duty. The project started from Mass Flow Meter, focusing on direct mass flow and density measurement.

Process Constraints

effluent parameters drift and probes foul with sludge and biofilm, and high solids and corrosive fractions, with large diurnal flow swings only amplify it. The Mass Flow Meter specification must therefore cover choosing tube geometry by flow range, entrained gas and hygienic needs.

Delivery Approach

Delivery was handled as the flow range — flow solution matched to line size, medium and range. Execution centred on choosing tube geometry by flow range, entrained gas and hygienic needs, together with stable compliance with Grade 1A discharge limits and online data reporting.

Field Results

Operation shows the benefit clearly — no temperature or pressure compensation needed, making custody transfer more credible, with confidence in this measuring point improving markedly.

Food & Beverage

Food & Beverage · Mass Flow Meter — Application Case

Customer Profile

The typical setting in Food & Beverage is dosing, pasteurising, filling and CIP stages. The measuring point is Mass Flow Meter; the focus is direct mass flow and density measurement.

Key Difficulties

Conditions are syrups, dairy and beverages that scale easily, under strict hygienic requirements and, on top of that, frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, which a standard configuration cannot handle for long. The design therefore starts with choosing tube geometry by flow range, entrained gas and hygienic needs.

Implementation

The scope ran through the flow range: flow solution matched to line size, medium and range. Technically it hinges on choosing tube geometry by flow range, entrained gas and hygienic needs, and on these requirements: food-safety and hygienic design per 3-A / EHEDG.

Customer Benefit

In practice this means no temperature or pressure compensation needed, making custody transfer more credible, which cut the workload on the site maintenance team.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Mass Flow Meter — Application Case

Project Background

The project covers reactors, metering vessels and finished-product tanks. The work centres on Mass Flow Meter and the core task is direct mass flow and density measurement.

Operating Challenges

The medium and duty are characterised by highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. So Mass Flow Meter cannot be specified generically — it calls for choosing tube geometry by flow range, entrained gas and hygienic needs.

Solution

The Ainstru engineering team worked through the flow range: flow solution matched to line size, medium and range. The configuration involves choosing tube geometry by flow range, entrained gas and hygienic needs, with these requirements in view: Ex certification and GMP traceability of records.

Results

Since start-up the system has run steadily; the practical result is no temperature or pressure compensation needed, making custody transfer more credible.

Power & Energy

Power & Energy · Mass Flow Meter — Application Case

Project Overview

The site is boiler feedwater, turbine condensate and FGD/DeNOx systems. The customer wanted Mass Flow Meter properly configured on the existing plant, with the aim of direct mass flow and density measurement.

Technical Challenges

What actually causes trouble is high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. All of this means the Mass Flow Meter configuration has to involve choosing tube geometry by flow range, entrained gas and hygienic needs.

Configuration

Supply and installation were organised through the flow range: flow solution matched to line size, medium and range. On site this meant choosing tube geometry by flow range, entrained gas and hygienic needs, checked line by line against: compliance with power-industry codes and unit availability targets.

Performance

After commissioning the outcome is no temperature or pressure compensation needed, making custody transfer more credible, and the readings are now used for process tuning.