HACH 1720E
The 1720E low-range turbidity analyzer can be used for turbidity monitoring of pre-filtration, post-filtration, sedimentation, and finished water in water treatment plants, municipal pipe network water quality monitoring, industrial process water quality monitoring, and turbidity monitoring of circulating cooling water, activated carbon filter effluent, membrane filtration effluent, etc. It is an online turbidity analyzer with stable performance and wide application.

Principle of Operation:

Incandescent light emitted from the sensor light source assembly travels downward into the turbidity analyzer and is scattered by suspended particles in the sample. A photodetector immersed in the water sample detects the scattered light at a 90° angle to the incident beam. The continuously flowing water sample passes through a bubble elimination system that removes entrained air bubbles from the sample stream, making the turbidity analyzer immune to variations in sample flow rate and pressure, thereby eliminating the most significant interference in low-range turbidity measurement.

Instrument Features:

  • The 1720E low-range turbidity analyzer features a built-in bubble elimination system, making the instrument immune to flow rate and pressure variations, effectively preventing interference with excellent reproducibility.

  • The 1720E turbidity analyzer uses a USEPA (U.S. Environmental Protection Agency) approved method, ensuring greater data universality.

  • The 1720E turbidity analyzer offers flexible calibration: either the recommended two-point calibration method using 0 and 20 NTU, or single-point calibration by comparison: select any point within the 1-40 NTU range.

  • In addition to NTU, the 1720E low-range turbidity meter displays multiple auxiliary measurement units: FTU, TE/F, mg/L.

  • The 1720E turbidity analyzer is very simple to clean and maintain; calibration is required once every three months.

  • Specifications

  • Measuring range:    0.0001~ 9.9999;10.000~ 99.999NTU;auto-ranging

  • Accuracy:    0 ~ 40NTU: ±2% of reading or ±0.02, whichever is greater

  • 40 ~ 100NTU: ±5% of reading

  • Resolution:    0~ 9.9999NTU: 0.0001NTU;

  • 10.000~ 99.999NTU: 0.001NTU

  • Reproducibility:    Better than ± 1.0% of reading or ± 0.002, whichever is greater

  • Response time:    Step response, initial response time approximately 1 minute 15 seconds

  • Signal averaging:    User-selectable at approximately 6, 30, 60, 90 seconds; user default is approximately 30 seconds

  • Sample flow rate:    200~750mL/min

  • Operating temperature:    0 ~50℃ for single-sensor systems, 0 ~40℃ for dual-sensor systems

  • Sample temperature:    0 ~ 50℃

  • Analog output:    0/4 ~ 20mA selectable. Programmable within 0 ~ 100NTU range

  • Relays:    3 SPDT, 230VAC, 5A; configurable setpoint alarms

  • Power requirements:    100~230VAC, 50/60Hz, auto-selecting; 40VA

  • Inlet piping:    1/4" NPT female, 1/4" compression fitting (provided)

  • Drain piping:    1/2" NPT female, 1/2" hose (provided)

  • Digital communication:    MODBUS/RS485, MODBUS/RS232, LonWorks protocol, Profibus (optional)

  • Standard methods:    Standard Method 2130B, USEPA 180.1, HACH Method 8195

  • Enclosure:    NEMA-4X/IP66 controller

  • Dimensions:    Turbidity meter: 25.4 × 30.5 ×40.6cm

Spare Parts

Spare Part Order No. Instrument Model Chinese Description English Description
1895000 1720E Low-Range Turbidity Analyzer Lamp LAMP ASSY
4500400 1720E Low-Range Turbidity Analyzer Light source LIGHT SOURCE ASSY
5221500 1720E Low-Range Turbidity Analyzer 1NTU calibration module ICE-PIC 1NTU CVD
5225000 1720E Low-Range Turbidity Analyzer 20NTU calibration module ICE-PIC 20NTU CVD
6011000 1720E Low-Range Turbidity Analyzer 1720E 1720E CPU To SC100 connector
6012000 1720E Low-Range Turbidity Analyzer Amplifier board CKT BD ASSY
6013800 1720E Low-Range Turbidity Analyzer Lamp cable 1720E LAMP CABLE

Ordering Guide

Complete System Ordering

  • 2976800CN    1720E turbidity meter with sc200 controller, probe cable length 2 m, 20NTU STABLCAL standard solution

  • 2978100CN    1720E turbidity meter with sc200 controller (single-channel, 220V), probe cable length 2 m, 20NTU STABLCAL standard solution

  • 2976900CN    1720E turbidity meter with sc200 controller (dual-channel, 24V), probe length 2 m, 20NTU STABLCAL standard solution

  • 2978200CN    1720E turbidity meter with sc200 controller (single-channel, 24V), probe length 2 m, 20NTU STABLCAL standard solution. For other communication output order numbers, please refer to the sc200 ordering instructions

Single Turbidity Probe

60101-01    1720E turbidity meter probe, probe cable length  2 m

Optional Accessories

  • 57960-00    25ft. (7.6 m) extension cable

  • 46308-00    Power cord (230VAC), with waterproof gland. (Note: Power cord must be ordered separately)

  • 52250-00    20NTU, ICE-PIC  calibration module

Source: Public information from the HACH Water Quality website

Municipal Wastewater Treatment

Municipal Wastewater Treatment · HACH-ONLINE — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on HACH-ONLINE and the core task is continuous outfall monitoring with Hach online instruments.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So HACH-ONLINE cannot be specified generically — it calls for configured by monitoring range, reagent replacement interval and conditioning.

Solution

The Ainstru engineering team worked through the online water-analysis line: integrating around each online monitoring point. The configuration involves configured by monitoring range, reagent replacement interval and conditioning, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is steady reagent and consumable supply, making upkeep predictable.

Food & Beverage

Food & Beverage · HACH-ONLINE — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted HACH-ONLINE properly configured on the existing plant, with the aim of continuous outfall monitoring with Hach online instruments.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the HACH-ONLINE configuration has to involve configured by monitoring range, reagent replacement interval and conditioning.

Configuration

Supply and installation were organised through the online water-analysis line: integrating around each online monitoring point. On site this meant configured by monitoring range, reagent replacement interval and conditioning, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is steady reagent and consumable supply, making upkeep predictable, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · HACH-ONLINE — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was continuous outfall monitoring with Hach online instruments.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means configured by monitoring range, reagent replacement interval and conditioning.

What We Did

We took a online water-analysis line approach — integrating around each online monitoring point. Delivery was built around configured by monitoring range, reagent replacement interval and conditioning, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — steady reagent and consumable supply, making upkeep predictable, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · HACH-ONLINE — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from HACH-ONLINE, focusing on continuous outfall monitoring with Hach online instruments.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The HACH-ONLINE specification must therefore cover configured by monitoring range, reagent replacement interval and conditioning.

Delivery Approach

Delivery was handled as the online water-analysis line — integrating around each online monitoring point. Execution centred on configured by monitoring range, reagent replacement interval and conditioning, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — steady reagent and consumable supply, making upkeep predictable, with confidence in this measuring point improving markedly.