Instrument Features:
Integrated design
The MS9000 automatic water quality analyzer adopts an integrated design with a small footprint. It is easy to relocate, transport, and install, reducing environmental impact and waste of manpower, material resources, and financial resources. The MS9000 multi-parameter water quality analyzer adopts an integrated automatic water quality monitoring design and can continuously monitor 9 water quality parameters including water temperature, pH, dissolved oxygen, conductivity, turbidity, permanganate index, ammonia nitrogen, total phosphorus, and total nitrogen.
Lower maintenance
The MS9000 multi-parameter automatic water quality analyzer is specifically designed for unattended applications. The industrial computer (including peripherals such as a monitor) provides on-site operators with a good human-machine interface (system workflow, real-time data, reports, historical data query and report export, parameter settings, instrument and system status, etc.). Based on instrument fault notifications, on-site operators can promptly analyze and identify the cause of faults and perform on-site maintenance.
Complete communication functions
The MS9000 multi-parameter automatic water quality analyzer adopts the TCP/IP communication protocol and interacts with the information center server according to the HJ 212-2017 data transmission standard. Authorized managers can monitor the on-site operation of the automatic water quality analyzer in real time through a web page, perform quality control and analysis on the monitoring data collected by the on-site instruments, report qualified data to relevant management departments and enterprises through the network, and notify the monitoring equipment maintenance unit of abnormal operation of the online automatic monitoring instruments. In addition, the system can also support the Modbus RTU communication protocol to implement data acquisition functions for third-party integrated systems.
-
General Technical Specifications
-
Display 15.6 inch, resolution 1920 x 1080, touch color TFT LCD display
-
Cabinet protection class IP55
-
Footprint (L×W) Less than 2 square meters (1.8 m × 1.1 m)
-
Electrical Specifications
-
Power supply 100~240 VAC, 50/60 Hz
-
Rated power (including air conditioner) 2 kW
-
UPS uninterruptible power supply Main unit 2000VA/1600W, plus 6 pcs 12V-38AH batteries, system standby time over 4 hours after unexpected power failure
-
Air conditioner Cooling capacity: 1575 W (cooling power consumption 650 W)
-
Heating power consumption: 1000 W
-
Internal circulation air volume: 500 m3/h
-
Refrigerant: R134a
-
Water Sampling and Pretreatment
-
Sampling pump Standard self-priming pump (one duty, one standby)
-
Maximum input power: 420 W
-
Maximum head: 30 m
-
Maximum flow rate: 33 L/min
-
Maximum suction lift: 8 m
-
*Compatible with submersible pump (customer-supplied) installation
-
Water sample pretreatment method Ammonia nitrogen: ultrafiltration, filtration accuracy 0.1 micron Total phosphorus, total nitrogen, permanganate index: ultrasonic homogenization, 2.0 MHz
-
Air compressor (self-cleaning, sludge removal) Power: 0.25 kW
-
Exhaust pressure: 0.8 MPa
-
Exhaust volume: 0.012 m3/min
-
Dosing pump (algae removal) Flow rate: 10.0 L/h
-
Pressure: 4 bar
-
Human-Machine Interface, Data Acquisition and Transmission
-
Data acquisition instrument communication interface protocol RJ45 <HJ212-2017>; RS485 <Modbus RTU>
-
Analyzer communication interface protocol RS485 <Modbus RTU>
-
Operating mode On-the-hour operating mode
-
Periodic operating mode
-
Continuous operating mode
-
Storage capacity ≧12 months of raw data and operation logs
-
Management authority Three-level operation management authority
-
Detection cycle (measurement interval) User-configurable (2 hours~24 hours, on-the-hour setting)
-
Recording cycle Raw data: user-configurable (2 hours~24 hours, on-the-hour setting) Operation log: real-time recording after event trigger
Ordering Guide
-
MS9000.01 MS9000 multi-parameter water quality analyzer
-
Source: Public information from the HACH water quality website
Case Studies
Municipal Wastewater Treatment · HACH-ONLINE — Application Case
Project Background
The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on HACH-ONLINE and the core task is continuous outfall monitoring with Hach online instruments.
Operating Challenges
The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So HACH-ONLINE cannot be specified generically — it calls for configured by monitoring range, reagent replacement interval and conditioning.
Solution
The Ainstru engineering team worked through the online water-analysis line: integrating around each online monitoring point. The configuration involves configured by monitoring range, reagent replacement interval and conditioning, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.
Results
Since start-up the system has run steadily; the practical result is steady reagent and consumable supply, making upkeep predictable.
Food & Beverage · HACH-ONLINE — Application Case
Project Overview
The site is dosing, pasteurising, filling and CIP stages. The customer wanted HACH-ONLINE properly configured on the existing plant, with the aim of continuous outfall monitoring with Hach online instruments.
Technical Challenges
What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the HACH-ONLINE configuration has to involve configured by monitoring range, reagent replacement interval and conditioning.
Configuration
Supply and installation were organised through the online water-analysis line: integrating around each online monitoring point. On site this meant configured by monitoring range, reagent replacement interval and conditioning, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.
Performance
After commissioning the outcome is steady reagent and consumable supply, making upkeep predictable, and the readings are now used for process tuning.
Chemical & Pharmaceutical · HACH-ONLINE — Application Case
Site Conditions
This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was continuous outfall monitoring with Hach online instruments.
The Problem
The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means configured by monitoring range, reagent replacement interval and conditioning.
What We Did
We took a online water-analysis line approach — integrating around each online monitoring point. Delivery was built around configured by monitoring range, reagent replacement interval and conditioning, with point-by-point checks on: Ex certification and GMP traceability of records.
Operating Outcome
In service the system performs as intended — steady reagent and consumable supply, making upkeep predictable, with routine maintenance falling noticeably.
Power & Energy · HACH-ONLINE — Application Case
Application Context
boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from HACH-ONLINE, focusing on continuous outfall monitoring with Hach online instruments.
Process Constraints
drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The HACH-ONLINE specification must therefore cover configured by monitoring range, reagent replacement interval and conditioning.
Delivery Approach
Delivery was handled as the online water-analysis line — integrating around each online monitoring point. Execution centred on configured by monitoring range, reagent replacement interval and conditioning, together with compliance with power-industry codes and unit availability targets.
Field Results
Operation shows the benefit clearly — steady reagent and consumable supply, making upkeep predictable, with confidence in this measuring point improving markedly.
Related Products
HACHSigma total phosphorus / orthophosphate analyzer
sc dichromate COD online analyzer
HACHOnline water hardness analyzer
HACHMulti-parameter online water analyzer
HACHOnline silica analyzer
HACHAmmonia nitrogen analyzer
HACHOnline free chlorine analyzer
HACH