Product Overview:
-
The MS6100 online automatic water quality analyzer is a multi-parameter online water quality analyzer capable of continuously monitoring 7 parameters: free chlorine, total chlorine, turbidity, pH, ORP, conductivity, and temperature. The turbidity module of this online automatic water quality analyzer adopts 360°X90° detection technology for greater accuracy. It features low maintenance and flexible configuration. The MS6100 multi-parameter online water quality analyzer uses the following detection methods for the 7 parameters respectively:
-
Free chlorine/total chlorine: N,N-diethyl-1,4-phenylenediamine photometric method (DPD method)
-
Turbidity: 90° scattered turbidimetric method, collecting scattered light at 360° around the incident beam;
-
pH/ORP/conductivity: electrochemical method;
-
Temperature: NTC30K
Instrument Features:
-
The multi-parameter online water quality analyzer can continuously monitor 7 water quality parameters including free chlorine, total chlorine, turbidity, pH, ORP, conductivity, and temperature
-
The turbidity module of the MS6100 online automatic water quality analyzer adopts an all-new 360°x90° detection technology, making turbidity testing faster, more accurate, and more convenient
-
Flexible and optional configuration, with complete communication functions
-
The MS6100 online automatic water quality analyzer adopts an integrated design, occupying minimal space, easy to install, with lower maintenance, specifically designed for unattended application scenarios
Technical Specifications
-
Measuring parameters Free chlorine, total chlorine, turbidity, pH, ORP, conductivity, and temperature
-
Measuring method Free chlorine/total chlorine: N,N-diethyl-1,4-phenylenediamine photometric method (DPD method)
-
Turbidity: 90-degree scattered turbidimetric method, collecting scattered light at 360 degrees around the incident beam;
-
pH/ORP/conductivity: electrochemical method;
-
Temperature: NTC30K
-
Measuring range Free chlorine/total chlorine: 0 ~ 5 mg/L as CL2;
-
Turbidity: 0 ~ 20 NTU;
-
pH: 4.00 ~ 10.00;
-
ORP: -1200 mV ~ +1200 mV;
-
Conductivity: 20.0 μS/cm ~ 2000 μS/cm;
-
Temperature: 0 °C ~ 50 °C
-
Detection limit Free chlorine/total chlorine: 0.03 mg/L;
-
Turbidity: 0.0032 NTU;
-
Conductivity: 6.0 μS/cm
-
Accuracy Free chlorine/total chlorine: ±5% or ±0.03 mg/L as CL2 (whichever is greater);
-
Turbidity: ±2% or ±0.01 NTU (whichever is greater); (based on Formazin primary standard solution at 25°C)
-
pH: ±0.02;
-
ORP: ±20 mV;
-
Conductivity: ±0.8 % F.S.;
-
Temperature: ±0.4 °C
-
Repeatability Free chlorine/total chlorine: 5 % or 0.01 mg/L as CL2 (whichever is greater);
-
Turbidity: 1 % or 0.006 NTU (whichever is greater); (based on Formazin primary standard solution at 25 °C)
-
pH: 0.01;
-
ORP: 10 mV;
-
Conductivity: 0.4 % F.S.;
-
Temperature: 0.2 °C
-
Response time Electrochemical electrodes (pH electrode/ORP electrode/conductivity electrode) T90 response time < 3 minutes;
-
Whole system T90 response time (calculated from when the water sample enters the instrument) < 10 minutes.
-
Measuring interval Free chlorine/total chlorine measuring interval configurable (continuous mode, 5 minutes, 10 minutes, 15 minutes, 20 minutes, 30 minutes);
-
Turbidity/pH/ORP/conductivity/temperature continuous measurement
-
Calibration method Free chlorine/total chlorine calibration: factory calibrated, using default calibration curve;
-
Turbidity calibration: StabCal® single-point calibration (20 NTU), Formazin two-point calibration, 2 to 6-point custom calibration;
-
pH calibration: single-point calibration, two-point calibration, three-point calibration;
-
Conductivity calibration: single-point calibration
-
Operating temperature 0 ° C to +45 °C
-
Sample temperature 4 °C ~ 40 °C.
-
Storage temperature Instrument: -20 °C to +55 °C;
-
Electrodes: -15 °C to +55 °C
-
Relative humidity 5 % ~ 95 % (non-condensing)
-
Power supply requirements (220±20) VAC/50 Hz (factory default configuration); or (115±5) VAC/60 Hz (manual switching required);
-
Analog output 7-channel isolated 4-20 mA output
-
Digital output 2 RS485 interfaces (one supports MODBUS
-
protocol, the other supports Hach SC protocol).
-
Sample flow rate The instrument sample inlet flow path is split into two, and the inlet flow rate of each path can be adjusted separately by the user:
-
Chlorine module flow adjustment range: 120-180 mL/min (recommended: 165 mL/min);
-
Turbidity (electrochemical) module flow adjustment range: 150-450 mL/min (recommended: 250 mL/min)
-
Certifications CE certification;
-
ETL certification.
-
Enclosure protection IP65 (with sealed door, with door latch)
-
Dimensions 49.0 cm (W) x 80.0 cm (H) x 36.5 cm (D)
-
Shipping weight 45 kg (including packaging)
Ordering Guide
-
8325700 MS6100.101 (Turbidity + single-channel chlorine/standard mainboard)
-
8325800 MS6100.102 (Turbidity + single-channel chlorine/full-configuration mainboard)
-
8325900 MS6100.111 (Turbidity + single-channel chlorine + electrochemical module/standard mainboard)
-
8332500 MS6100.112 (Turbidity + single-channel chlorine + electrochemical module/full-configuration mainboard)
-
8329400 MS6100.201 (Turbidity + dual-channel chlorine/standard mainboard)
-
8329800 MS6100.202 (Turbidity + dual-channel chlorine/full-configuration mainboard)
-
8330000 MS6100.211 (Turbidity + dual-channel chlorine + electrochemical module/standard mainboard)
-
8330600 MS6100.212 (Turbidity + dual-channel chlorine + electrochemical module/full-configuration mainboard)
-
8331800 MS6100 pH electrode (including packaging)
-
8326800 MS6100 conductivity electrode (including packaging)
-
8331600 MS6100 ORP electrode (including packaging)
Source: Public information from the Hach Water Quality website
Case Studies
Municipal Wastewater Treatment · HACH-ONLINE — Application Case
Project Background
The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on HACH-ONLINE and the core task is continuous outfall monitoring with Hach online instruments.
Operating Challenges
The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So HACH-ONLINE cannot be specified generically — it calls for configured by monitoring range, reagent replacement interval and conditioning.
Solution
The Ainstru engineering team worked through the online water-analysis line: integrating around each online monitoring point. The configuration involves configured by monitoring range, reagent replacement interval and conditioning, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.
Results
Since start-up the system has run steadily; the practical result is steady reagent and consumable supply, making upkeep predictable.
Food & Beverage · HACH-ONLINE — Application Case
Project Overview
The site is dosing, pasteurising, filling and CIP stages. The customer wanted HACH-ONLINE properly configured on the existing plant, with the aim of continuous outfall monitoring with Hach online instruments.
Technical Challenges
What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the HACH-ONLINE configuration has to involve configured by monitoring range, reagent replacement interval and conditioning.
Configuration
Supply and installation were organised through the online water-analysis line: integrating around each online monitoring point. On site this meant configured by monitoring range, reagent replacement interval and conditioning, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.
Performance
After commissioning the outcome is steady reagent and consumable supply, making upkeep predictable, and the readings are now used for process tuning.
Chemical & Pharmaceutical · HACH-ONLINE — Application Case
Site Conditions
This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was continuous outfall monitoring with Hach online instruments.
The Problem
The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means configured by monitoring range, reagent replacement interval and conditioning.
What We Did
We took a online water-analysis line approach — integrating around each online monitoring point. Delivery was built around configured by monitoring range, reagent replacement interval and conditioning, with point-by-point checks on: Ex certification and GMP traceability of records.
Operating Outcome
In service the system performs as intended — steady reagent and consumable supply, making upkeep predictable, with routine maintenance falling noticeably.
Power & Energy · HACH-ONLINE — Application Case
Application Context
boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from HACH-ONLINE, focusing on continuous outfall monitoring with Hach online instruments.
Process Constraints
drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The HACH-ONLINE specification must therefore cover configured by monitoring range, reagent replacement interval and conditioning.
Delivery Approach
Delivery was handled as the online water-analysis line — integrating around each online monitoring point. Execution centred on configured by monitoring range, reagent replacement interval and conditioning, together with compliance with power-industry codes and unit availability targets.
Field Results
Operation shows the benefit clearly — steady reagent and consumable supply, making upkeep predictable, with confidence in this measuring point improving markedly.
Related Products
HACHSigma total phosphorus / orthophosphate analyzer
sc dichromate COD online analyzer
HACHOnline water hardness analyzer
HACHMulti-parameter automatic water analyzer
HACHOnline silica analyzer
HACHAmmonia nitrogen analyzer
HACHOnline free chlorine analyzer
HACH