Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

9185 Ozone analyzer

9185 Ozone analyzer
Ozone analyzer
HACH 9185
Configurable Models 2 models
The 9185 sc online ozone monitor uses the selective membrane electrode method, offering fast response and high accuracy; it requires no frequent replacement of electrolyte or membrane, features strong anti-interference capability and low maintenance, and is an online ozone analyzer suitable for online ozone monitoring in water.

Principle of Operation:

  • 9185 sc ozone analyzer detection principle: O3 is reduced at the gold electrode (cathode): O3+H2O+2e-→O2+2OH-

  • At the silver reference electrode (anode): silver is oxidized to: Ag+, which reacts with bromide ions in the electrolyte: 2Br-+2Ag→2AgBr+2e-

  • The amount of O3 reduced at the cathode generates a current proportional to the O3 concentration.

Application Industries:

The 9185 sc ozone analyzer is suitable for ozone disinfection monitoring in drinking water, wastewater, industrial process water, and pure water industries.

Instrument Features:

  • The online ozone monitor uses a selective membrane electrode;

  • The online ozone monitor is not subject to interference from pH, chlorine, bromine, chlorine dioxide, or hydrogen peroxide in the sample;

  • The online ozone monitor is easy to calibrate and maintain; the membrane replacement process takes only a few seconds.

Technical Specifications

  • Measuring range:    5ppb ~ 2ppm

  • Accuracy:    ± 3 % or ± 10ppb , whichever is greater  Sample flow rate:  14 L/hr

  • Lower detection limit:    5 ppb  Response time:  90%  ≤90 s

  • Sample flow rate:    200 ~ 250 mL/min

  • Ambient temperature:    0 ~ 45℃

  • Sample temperature:    2 ~ 45℃  Power consumption:  1.5 W

  • Calibration interval:    2 months

  • Maintenance interval:    6 months, typical maintenance is membrane replacement, electrolyte

  • Mounting method:    Panel mounting

  • Sample inlet connection:    1/4-in. O.D.

  • Drain connection:    1/2-in. I.D.

  • Protection class:    IP 66(NEMA 4X)

Ordering Guide

Ozone Analyzer Panel

LXV433.99.00001 includes 9185sc ozone sensor, panel

Controller

  • LXV404.99.00552 sc200 standard controller, dual-channel, digital, 4-20mA

  • LXV404.99.01552 sc200 controller, dual-channel, digital, MODBUS RS232/485

  • For other sc200 ordering options, please refer to the ordering instructions in the sc200 brochure

Accessories

  • 09185=A=1000 9185sc sensor

  • 09185=A=3500 Pre-installed membrane, 4 pcs

  • 09185=A=3600 9185sc electrolyte

Source: Public information from the HACH Water Quality website

2 models · click to collapse
Municipal Wastewater Treatment

Municipal Wastewater Treatment · HACH-ONLINE — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on HACH-ONLINE and the core task is continuous outfall monitoring with Hach online instruments.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So HACH-ONLINE cannot be specified generically — it calls for configured by monitoring range, reagent replacement interval and conditioning.

Solution

The Ainstru engineering team worked through the online water-analysis line: integrating around each online monitoring point. The configuration involves configured by monitoring range, reagent replacement interval and conditioning, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is steady reagent and consumable supply, making upkeep predictable.

Food & Beverage

Food & Beverage · HACH-ONLINE — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted HACH-ONLINE properly configured on the existing plant, with the aim of continuous outfall monitoring with Hach online instruments.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the HACH-ONLINE configuration has to involve configured by monitoring range, reagent replacement interval and conditioning.

Configuration

Supply and installation were organised through the online water-analysis line: integrating around each online monitoring point. On site this meant configured by monitoring range, reagent replacement interval and conditioning, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is steady reagent and consumable supply, making upkeep predictable, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · HACH-ONLINE — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was continuous outfall monitoring with Hach online instruments.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means configured by monitoring range, reagent replacement interval and conditioning.

What We Did

We took a online water-analysis line approach — integrating around each online monitoring point. Delivery was built around configured by monitoring range, reagent replacement interval and conditioning, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — steady reagent and consumable supply, making upkeep predictable, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · HACH-ONLINE — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from HACH-ONLINE, focusing on continuous outfall monitoring with Hach online instruments.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The HACH-ONLINE specification must therefore cover configured by monitoring range, reagent replacement interval and conditioning.

Delivery Approach

Delivery was handled as the online water-analysis line — integrating around each online monitoring point. Execution centred on configured by monitoring range, reagent replacement interval and conditioning, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — steady reagent and consumable supply, making upkeep predictable, with confidence in this measuring point improving markedly.