Principle of Operation:
-
The electrolyte and permeable membrane separate the electrolytic cell from the water sample. Chlorine dioxide can penetrate the membrane. A fixed potential difference is maintained between the two electrodes of the chlorine dioxide analyzer/measurement instrument, and the generated current is proportional to the chlorine dioxide concentration.
-
At the cathode: ClO2+4H++5e-→Cl-+2H2O
-
At the anode: Cl-+Ag→AgCl+e-
-
The 9187 sc chlorine dioxide analyzer features a selective membrane sensor with a temperature probe for temperature compensation.
Industry Applications:
The 9187 sc chlorine dioxide analyzer is suitable for online monitoring of chlorine dioxide concentration in drinking water and industrial process water disinfection processes.
Instrument Features:
-
Wide measuring range
-
The 9187 sc chlorine dioxide analyzer uses a selective membrane sensor to measure chlorine dioxide, with a measuring range of 0.010 - 2 ppm (mg/L).
-
Temperature compensation
-
The sensor of the 9187 sc chlorine dioxide analyzer has a built-in temperature probe for automatic temperature compensation.
-
Accurate measurement
-
The 9187 sc chlorine dioxide measurement instrument is not subject to interference from chlorine, bromine, hydrogen peroxide, or O3, ensuring accurate measurement.
-
Low maintenance
-
The 9187 sc chlorine dioxide analyzer is generally calibrated once every two months, and the electrolyte and membrane are replaced every six months.
Technical Specifications
-
Measuring range: 0.010 - 2 ppm (mg/L) (Cl2O
-
Minimum detection limit: 10 ppb or 0.01 mg/L ClO2
-
Accuracy: 5% or± 10 ppb ClO2
-
Response time: 90% in less than approximately 90 seconds
-
Sample flow rate: 200~250 mL/min
-
Storage temperature: -20~60℃
-
Operating temperature: 0~45℃
-
Sample temperature: 2~45℃
-
Calibration method: Laboratory comparison method
-
Calibration interval: Once / 2 months
-
Maintenance interval: Generally replace membrane and electrolyte every six months
-
Sample inlet connection: 1/4-in. O.D.
-
Drain connection: 1/2-in. I.D.
-
Protection class: IP-66/NEMA 4X
-
Instrument dimensions: 270 x 250 mm
Ordering Guide
ClO2 Analyzer Panel
LXV434.99.00001 Includes 9187sc ClO2 sensor, panel
Controller
-
LXV404.99.00552 sc200 standard controller, dual-channel, digital
-
LXV404.99.01552 sc200 controller, dual-channel, digital, MODBUS RS232/485
-
For other sc200 ordering options, please refer to the ordering instructions in the sc200 brochure
Accessories
-
09187=A=1000 9187sc sensor
-
09187=A=3500 9187sc selective membrane, 4 pcs
-
09187=A=3600 9187sc electrolyte
Source: Public information from the HACH Water Quality website
Case Studies
Municipal Wastewater Treatment · HACH-ONLINE — Application Case
Project Background
The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on HACH-ONLINE and the core task is continuous outfall monitoring with Hach online instruments.
Operating Challenges
The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So HACH-ONLINE cannot be specified generically — it calls for configured by monitoring range, reagent replacement interval and conditioning.
Solution
The Ainstru engineering team worked through the online water-analysis line: integrating around each online monitoring point. The configuration involves configured by monitoring range, reagent replacement interval and conditioning, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.
Results
Since start-up the system has run steadily; the practical result is steady reagent and consumable supply, making upkeep predictable.
Food & Beverage · HACH-ONLINE — Application Case
Project Overview
The site is dosing, pasteurising, filling and CIP stages. The customer wanted HACH-ONLINE properly configured on the existing plant, with the aim of continuous outfall monitoring with Hach online instruments.
Technical Challenges
What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the HACH-ONLINE configuration has to involve configured by monitoring range, reagent replacement interval and conditioning.
Configuration
Supply and installation were organised through the online water-analysis line: integrating around each online monitoring point. On site this meant configured by monitoring range, reagent replacement interval and conditioning, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.
Performance
After commissioning the outcome is steady reagent and consumable supply, making upkeep predictable, and the readings are now used for process tuning.
Chemical & Pharmaceutical · HACH-ONLINE — Application Case
Site Conditions
This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was continuous outfall monitoring with Hach online instruments.
The Problem
The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means configured by monitoring range, reagent replacement interval and conditioning.
What We Did
We took a online water-analysis line approach — integrating around each online monitoring point. Delivery was built around configured by monitoring range, reagent replacement interval and conditioning, with point-by-point checks on: Ex certification and GMP traceability of records.
Operating Outcome
In service the system performs as intended — steady reagent and consumable supply, making upkeep predictable, with routine maintenance falling noticeably.
Power & Energy · HACH-ONLINE — Application Case
Application Context
boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from HACH-ONLINE, focusing on continuous outfall monitoring with Hach online instruments.
Process Constraints
drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The HACH-ONLINE specification must therefore cover configured by monitoring range, reagent replacement interval and conditioning.
Delivery Approach
Delivery was handled as the online water-analysis line — integrating around each online monitoring point. Execution centred on configured by monitoring range, reagent replacement interval and conditioning, together with compliance with power-industry codes and unit availability targets.
Field Results
Operation shows the benefit clearly — steady reagent and consumable supply, making upkeep predictable, with confidence in this measuring point improving markedly.
Related Products
HACHSigma total phosphorus / orthophosphate analyzer
sc dichromate COD online analyzer
HACHOnline water hardness analyzer
HACHMulti-parameter automatic water analyzer
HACHMulti-parameter online water analyzer
HACHOnline silica analyzer
HACHAmmonia nitrogen analyzer
HACH