Measuring method:
The EZ7300 Online Adenosine Triphosphate ATP Analyzer uses luciferin and luciferase to determine adenosine triphosphate (ATP) through a chemiluminescence reaction, in accordance with ASTM D4012-81 standard method.
Instrument features:
-
1) The EZ7300 Online Adenosine Triphosphate ATP Analyzer complies with ASTM 4012-81 standard method
-
2) Simultaneously detects different ATP components in water and analyzes the total ATP content
-
3) Unlike the plate count method, it is not affected by culture medium composition, making ATP detection more accurate
-
4) The EZ7300 Online Adenosine Triphosphate ATP Analyzer enables automated, intelligent analysis with low ATP detection cost
-
5) Easy reagent replacement and automatic system self-cleaning result in low maintenance cost for the ATP analyzer
-
6) The EZ7300 Online Adenosine Triphosphate ATP Analyzer supports multi-stream analysis (up to 8 channels)
Technical specifications
-
Measuring parameter Adenosine triphosphate (ATP)
-
Measuring method Uses luciferin and luciferase to determine adenosine triphosphate (ATP) through a chemiluminescence reaction, in accordance with ASTM D4012-81 standard method
-
Measuring range 0.5 - 200 pg/mL ATP
-
Detection limit ≤0.05 pg/mL(0.1pM) ATP
-
Accuracy ≤4% F.S. (using standard solution)
-
Measuring interval 7-10 minutes (including sample digestion)
-
Verification Automatic verification, frequency configurable
-
Calibration Automatic 2-point calibration, frequency configurable
-
Operating temperature 10℃ - 30℃±4℃,relative humidity: 5%-95% (non-condensing)
-
Reagent requirements During use: 4℃ - 8℃, store away from light
-
For long-term storage: -20℃, store in a dark environment
-
Flow rate 100-300ml/min
-
Sample temperature 10℃ - 30℃
-
Power supply requirements (220±20) VAC/50 Hz (factory default configuration); or (115±5) VAC/60 Hz (manual switching required);
-
Analog output 4-20 mA, maximum 500 ohm load, 1 analog output as standard, up to 8 (optional)
-
Digital output Optional: RS232, Modbus (TCP/IP, RS485)
-
Sample requirements Maximum particle size 100μm, <0.1 g / L; turbidity <50 NTU
-
Certifications Complies with CE / UL certification
-
Enclosure protection Analyzer main unit: IP55;
-
PC panel: IP65
-
Dimensions 690mmx 465mmx 330mm
-
Shipping weight 30kg
Ordering guide
-
EZ7300.99001102 EZ7300 ATP analyzer, standard measuring range: 0.5-200 pg/mL, 1 channel, 1 x 0/4-20mA output
-
EZ7300.99001E02 EZ7300 ATP analyzer, standard measuring range: 0.5-200 pg/mL, 1 channel, 1 x 0/4-20mA output + Modbus RS485
Source: Public information from HACH water quality website
Case Studies
Municipal Wastewater Treatment · HACH-ONLINE — Application Case
Project Background
The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on HACH-ONLINE and the core task is continuous outfall monitoring with Hach online instruments.
Operating Challenges
The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So HACH-ONLINE cannot be specified generically — it calls for configured by monitoring range, reagent replacement interval and conditioning.
Solution
The Ainstru engineering team worked through the online water-analysis line: integrating around each online monitoring point. The configuration involves configured by monitoring range, reagent replacement interval and conditioning, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.
Results
Since start-up the system has run steadily; the practical result is steady reagent and consumable supply, making upkeep predictable.
Food & Beverage · HACH-ONLINE — Application Case
Project Overview
The site is dosing, pasteurising, filling and CIP stages. The customer wanted HACH-ONLINE properly configured on the existing plant, with the aim of continuous outfall monitoring with Hach online instruments.
Technical Challenges
What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the HACH-ONLINE configuration has to involve configured by monitoring range, reagent replacement interval and conditioning.
Configuration
Supply and installation were organised through the online water-analysis line: integrating around each online monitoring point. On site this meant configured by monitoring range, reagent replacement interval and conditioning, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.
Performance
After commissioning the outcome is steady reagent and consumable supply, making upkeep predictable, and the readings are now used for process tuning.
Chemical & Pharmaceutical · HACH-ONLINE — Application Case
Site Conditions
This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was continuous outfall monitoring with Hach online instruments.
The Problem
The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means configured by monitoring range, reagent replacement interval and conditioning.
What We Did
We took a online water-analysis line approach — integrating around each online monitoring point. Delivery was built around configured by monitoring range, reagent replacement interval and conditioning, with point-by-point checks on: Ex certification and GMP traceability of records.
Operating Outcome
In service the system performs as intended — steady reagent and consumable supply, making upkeep predictable, with routine maintenance falling noticeably.
Power & Energy · HACH-ONLINE — Application Case
Application Context
boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from HACH-ONLINE, focusing on continuous outfall monitoring with Hach online instruments.
Process Constraints
drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The HACH-ONLINE specification must therefore cover configured by monitoring range, reagent replacement interval and conditioning.
Delivery Approach
Delivery was handled as the online water-analysis line — integrating around each online monitoring point. Execution centred on configured by monitoring range, reagent replacement interval and conditioning, together with compliance with power-industry codes and unit availability targets.
Field Results
Operation shows the benefit clearly — steady reagent and consumable supply, making upkeep predictable, with confidence in this measuring point improving markedly.
Related Products
HACHSigma total phosphorus / orthophosphate analyzer
sc dichromate COD online analyzer
HACHOnline water hardness analyzer
HACHMulti-parameter automatic water analyzer
HACHMulti-parameter online water analyzer
HACHOnline silica analyzer
HACHAmmonia nitrogen analyzer
HACH